Gradient Optimized Gradient-Echo Gradient Moment Nulling Sequences for Flow Compensation of Brain Images

  • Jahng, Geon-Ho;Stephen Pickup
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.20-26
    • /
    • 2000
  • Gradient moment nulling techniques require the introduction of an additional gradient on each axis for each order of motion correction to be applied. The additional gradients introduce new constraints on the sequence design and increase the demands on the gradient system. The purpose of this paper is to demonstrate techniques for optimization of gradient echo gradient moment nulling sequences within the constraints of the gradient hardware. Flow compensated pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. The design of the gradient moment nulling sequences requires the solution of a linear system of equations. A Mathematica package was developed that interactively solves the gradient moment nulling problem. The package allows the physicist to specify the desired order of motion compensation and the duration of the gradients in the sequence with different gradient envelopes. The gradient echo sequences with first, second, and third order motion compensation were implemented with minimum echo time. The sequences were optimized to take full advantage of the capabilities of the gradient hardware. The sequences were used to generate images of phantoms and human brains. The optimized sequences were found to have better motion compensation than comparable standard sequences.

  • PDF

18MeV 선형가속기의 ARC Therapy에 관한 고찰 (A Study on ARC Therapy of 18MeV Linear Accelerator)

  • 김성규;신세원;김명세
    • Journal of Yeungnam Medical Science
    • /
    • 제5권2호
    • /
    • pp.31-36
    • /
    • 1988
  • 회전조사시 회전각도에 따른 계산치와 측정치를 비교, 검토하여 마음과 같은 결과를 얻었다. $90^{\circ}$ 회전시에는 계산치와 측정치와는 4.5%의 차이를 나타내었고 $120^{\circ}$ 회전시에는 4.4%, $180^{\circ}$ 회전시에는 3.9%, $240^{\circ}$ 회전시에는 2.9%, $360^{\circ}$ 회전시에는 2.1%의 차이를 나타내어 회전각도가 클수록 계산치와 측정치와의 차이는 적은 것으로 나타났다. 또한 회전각도에 따라 최고선량지점이 상부로 이동하는 정도는 $90^{\circ}$에서 $240^{\circ}$까지 회전할 때 tumor depth가 4.5cm일 경우에 는 1.67cm에서 1.10cm 정도 상부로 이동하였으며, tumor depth가 8cm일 경우에는 2.45cm에서 1.40cm 정도 상부로 이동하는 것으로 나타났다.

  • PDF

A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF

근접방사선치료에 관한 사고유형과 영향분석 연구 (Study of Failure Mode and Effect Analysis in Brachytherapy)

  • 이순성;박동욱;신동오;김동욱;김금배;오윤진;김주혜;권나혜;김경민;최상현
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.627-635
    • /
    • 2017
  • 근접방사선치료는 일반적으로 외부방사선치료와 병행하여 수행되고 치료단계가 매우 복잡하며 이로 인해 방사선 사고가 발생될 수 있다. 본 연구에서는 이를 해결하기 위해 근접방사선치료에 사고유형과 영향 분석(Failure mode and effects analysis, FMEA) 방법을 적용하여 프로세스 맵을 구성하고 이를 기반으로 각 치료단계에 대한 위해도를 산출하였다. 프로세스 맵은 "외래 및 진료"와 "근접방사선 모의치료", "CT 모의 치료", "근접방사선치료계획", "방사선치료"로 총 5단계로 구성하였으며, 각 치료단계를 세분화하여 세부단계를 작성하였다. 위해도를 산출하기 위해 의사와 의학물리사, 선량설계사, 방사선사, 간호사가 참여하여 세부단계마다 발생빈도와 심각도, 불검출도를 평가하였다. 전반적으로 프로세스 맵은 각 치료단계마다 환자 신원 확인 절차가 우선적으로 수행되며, 이는 다른 환자로 오인하여 서로 다른 치료계획이 수립되어 방사선사고가 발생될 우려가 있다. 프로세스 맵을 기반으로 작성한 세부단계에 대해 위해도를 평가한 결과, 전반적으로 "외래 및 진료"와 "근접방사선치료계획" 과정이 높은 위해도로 평가되었다. 직종마다 평가한 위해도는 서로 다른 경향을 보였으며, 간호사는 방사선치료를 제외한 모든 과정이 55점 이상의 위해도를 보였으며, "근접방사선 모의치료" 과정이 88.8점으로 가장 높았다. 방사선치료를 수행하는 의료기관마다 치료단계가 다소 차이가 있으므로 해당 기관에 대한 프로세스 맵을 작성하고 위해도를 산출하여 중점관리 항목을 집중적으로 리스크 관리가 수행되어야 할 것으로 생각된다.

국내 병원 별 방사선치료의 진료 구조 현황(1997년 현황을 중심으로 한 선진국과의 비교 구) (The Structure of Korean Radiation Oncology in 1997)

  • 김미숙;류성렬;조철구;유헝준;양광모;지영훈;이동훈;이동한;김도준
    • Radiation Oncology Journal
    • /
    • 제17권2호
    • /
    • pp.172-178
    • /
    • 1999
  • 목적 : 국내 방사선치료에 대한 전국현황의 통계를 1997년을 중심으로 한 병원 별 진료 장비, 인력 현황을 조사하고 그에 대한 연간 신환자수의 분포를 검토하여 그 결과를 선진국의 예와 비교함으로써 현재의 국내 방사선치료의 진료 수준을 분석하고자 하였다. 대상 및 방법 : 1998년에 치료방사선과가 있는 전국의 42개 병원을 대상으로 설문조사를 통해 자료를 수집하였다. 통계자료는 1997년 1월부터 12월까지 총 1년으로 하였고 통계처리는 마이크로소프트사의 Excel 프로그램을 이용하였다. 결과 : 1997년에 국내에서 42개의 병원이 71대의 외부 방사선치료장치, 100명의 치료방사선과 전문의, 26명의 의학 물리학자, 205명의 방사선사가 있었고 연간 19,773명의 신환을 치료하였다. 전국 42개 병원의 89$\%$,는 최소한 6 MeV 이상의 선형가속기를 보유하였고 95$\%$는 모의 조사장치를 소유한 반면 $5\%$는 모의 조사장치를 가지고 있지 않았다. 컴퓨터 치료계획을 할 수 있는 장비를 소유한 병원은 $91\%$였고, $83\%$는 정도관리 지침서를 가지고 있다고 응답하였다. 병원별 치료방사선과 의사가 단지 1명인 병원이 36%이었으며 의학 물리학자가 없는 곳이 38$\%$였다. 한 병원당년간 환자수 분포의 중앙값은 348명, 기계당 환자수의 중앙값은 263명, 방사선종양학과 전문의당 환자수의 중앙값은 171명, 방사선사당 환자수의 중앙값은 81명, 기계당 방사선사의 중앙값은 3명이다. 결론 : 국내의 치료방사선과를 보유한 병원의 수, 방사선치료를 받는 환자수 및 치료장비수는 일본 및 미국과 비교하여 인구비례로 계산해 볼때 매우 적은 편이다. 치료장비면에서는 선형가속기, 모의 조사장치, 컴퓨터 치료계획 시스템의 수준이 미국과 비교하여 크게 차이가 없었다. 의사, 방사선사에 대한 환자수의 부하(loading)는 미국과 비교하여 큰 차이는 없었다. 그러나 인력면에서 의학물리학자가 없는 병원의 수가 상당히 많은 관계로 이의 보완을 위해서 미국과 같은 part time 제도의 운영도 해 볼 수 있을 것이다.

  • PDF