• Title/Summary/Keyword: Medical measurement

Search Result 2,743, Processing Time 0.039 seconds

Diagnostic Value of Ceruloplasmin in the Diagnosis of Pediatric Wilson's Disease

  • Kim, Jung Ah;Kim, Hyun Jin;Cho, Jin Min;Oh, Seak Hee;Lee, Beom Hee;Kim, Gu-Hwan;Choi, Jin-Ho;Kim, Kyung Mo;Yoo, Han-Wook
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.3
    • /
    • pp.187-192
    • /
    • 2015
  • Purpose: Measurement of serum ceruloplasmin level is the first step in screening for Wilson's disease (WD). Despite the rarity of WD in the general population, ceruloplasmin levels are routinely measured through hepatitis screening in both adults and children. Herein, we evaluated the diagnostic value of ceruloplasmin for the diagnosis of WD among children with hepatitis. Methods: We retrospectively reviewed data on serum ceruloplasmin levels measured as a serologic marker for patients with hepatitis at Asan Medical Center (Seoul, Korea) between from January 2004 to November 2013. The diagnosis of WD was confirmed by the identification of pathogenic variants in the ATP7B gene. To determine the diagnostic accuracy of ceruloplasmin, receiver operation characteristic (ROC) curves were constructed and the area under curve (AUC) were calculated. Results: Measurements of serum ceruloplasmin were performed in 2,834 children who had hepatitis. Among these, 181 (6.4%) children were diagnosed with WD. The sensitivity, specificity, and accuracy of a ceruloplasmin level of <20 mg/dL in the discrimination of WD were 93.4%, 84.2%, and 84.8%, respectively. In this study, 418 (14.7%) false-positive cases and 12 (0.4%) false-negative cases were noted. Using a ROC curve, a ceruloplasmin level of ${\leq}16.6mg/dL$ showed the highest AUC value (0.956) with a sensitivity of 91.2%, a specificity of 94.9%, and an accuracy of 94.7%. Conclusion: The measurement of serum ceruloplasmin was frequently used for the screening of WD in children, despite a low positive rate. The diagnostic value of ceruloplasmin may be strengthened by adopting a new lower cut-off level.

Perceived Service Quality among Outpatients Visiting Hospitals and Clinics and Their Willingness to Re-utilize the Same Medical Institutions

  • Jung, Min-Soo;Lee, Keon-Hyung;Choi, Man-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.3
    • /
    • pp.151-159
    • /
    • 2009
  • Objectives : This study was to determine how the perception and the satisfaction of outpatients who utilized clinics and hospitals are structurally related with their willingness to utilize the same institution in the future. Methods : Three hundred and ten responses (via convenient sampling) were collected from 5 hospitals and 20 clinics located in Seoul listed in the "Korea National Hospital Directory 2005". Service quality was utilized as the satisfaction measurement tool. For analysis, we used a structural equation modeling method. Results : The determining factors for general satisfaction with medical services are as follows: medical staff, reasonability of payment, comfort and accessibility. Such results may involve increased competition in the medical market and increased demands for quality medical services, which drive the patients to visit hospitals on their own on the basis of changed determining factors for satisfaction. Conclusions : The structural equation model showed that the satisfaction of outpatients with the quality of medical services is influenced by a few sub-dimensional satisfaction factors. Among these sub-dimensional satisfaction factors, the satisfaction with medical staff and payment were determined to exert a significant effect on overall satisfaction with the quality of medical services. The structural relationship in which overall satisfaction perceived by patients significantly influences their willingness to use the same institution in the future was also verified.

Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation (저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현)

  • Yoon, Wan-Oh;Kang, Suk-Youb;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.