• Title/Summary/Keyword: Medical isotope

Search Result 92, Processing Time 0.031 seconds

The Thoracic Radiculopathy in SAPHO Syndrome - A Case Report - (SAPHO 증후근에서의 신경근병증 - 증 례 보 고 -)

  • Han, Seok;Cho, Tai Hyoung;Kim, Se Hoon;Lim, Dong Jun;Park, Jung Yul;Chung, Yong Gu;Suh, Jung Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1320-1323
    • /
    • 2001
  • SAPHO syndrome is an acronym for an increasingly recognized syndrome of synovitis, acne, pustulosis, hyperostosis, and osteitis. Most of the previously reported case are from Japan and Europe. The authors report a case of SAPHO syndrome in Korean female who presented with extrasternal neurologic symptoms. A 60-year-old female with thoracic and right chest wall pain presented with the sternocostoclavicular hyperostosis, and recurrent aseptic osteitis. Previously, she had hystrectomy and thyroidectomy due to uterine malignancy 25 years ago. Also, she started to take medications for palm and sole pustulosis 7 days prior to admission. Through evaluation of clinical, radiological, serological studies, studies was done along with bone needle biopsy for the biological reassessment. The hyperostosis was found in the pedicles of thoracic 8, 9, 10 vertebrae and sternoclavicular joint. Radio-isotope bone scan showed an accumulation of tracer in thoracic vertebra. The bone biopsy from these site showed increased osseous turnover, thickening of trabeculae accompanied by mild acculuation of granulation tissue and round cell infiltration, compatible with mild chronic inflammation with marrow fibrosis. The patient showed good response to conservative management. The authors report a case of SAPHO syndrome with thoracic radiculopathy. It is considered that SAPHO syndrome is related to spondyloarthropathy, and appears to have benign disease process with good prognosis.

  • PDF

The production and application of therapeutic 67Cu radioisotope in nuclear medicine

  • Kim, Gye-Hong;Lee, Kyo Chul;Park, Ji-Ae;An, Gwang-Il;Lim, Sang Mo;Kim, Jung Young;Kim, Byung Il
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Radioisotopes emitting low-range highly ionizing radiation such as ${\beta}$-particles are of increasing significance in internal radiotherapy. Among the ${\beta}$-particle emitting radioisotopes, $^{67}Cu$ is an attractive radioisotope for various nuclear medicine applications due to its medium energy ${\beta}$-particle, gamma emissions, and 61.83-hour half-life, which can also be used with $^{64}Cu$ for PET imaging. The production and application of the ${\beta}$-emitting radioisotope $^{67}Cu$ for therapeutic radiopharmaceutical are outlined, and different production routes are discussed. A survey of copper chelators used for antibody labeling is provided. It has been produced via proton, alpha, neutron, and gamma irradiations followed by solvent extraction, ion exchange, electrodeposition. Clinical studies using $^{67}Cu$-labelled antibodies in lymphoma, colon carcinoma and bladder cancer patients are reviewed. Widespread use of this isotope for clinical studies and preliminary treatments has been limited by unreliable supplies, cost, and difficulty in obtaining therapeutic quantities.

A Survey of the Management of Patient Dose at Medical Center (의료기관의 환자 피폭선량 관리 실태조사)

  • Jeon, Go-Eun;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Medical radiation therapy using radioactive isotope I-131 is an extremely critical part of nuclear medicine. It is important to evaluate patients' radiation exposure dose for the safe handling of radiation in the medical area. Cautions related to patients' exposure to radiation are as follows. First, the dose should not exceed the level required for medical purpose. Second, unnecessary exposure should be avoided. Third, it should be considered carefully first whether the same medical purpose is attainable without the use of radiation. For these purposes, we need to evaluate patients' radiation exposure dose. Thus, in order to promote the safety of patients in medical wards, this study sampled air using an air sampler and measured the radioactivity of the sample using a gamma counter. According to the results of measuring I-131 in medical wards, the highest level, the average and the lowest level were $404.11Bq/m^3$, $228.27Bq/m^3$ and $126.17Bq/m^3$, respectively.

  • PDF

Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry

  • Lee, Sang-Hoo;Kwon, Soon-Ho;Shin, Hye-Jin;Park, Ji-Myeong;Lim, Hwan-Sub;Lee, Kyoung-Ryul;Kim, Young-Jin
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.761-765
    • /
    • 2010
  • Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-$d_3$ as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

Radiation Safety Consideration Regarding the Treatment which uses the Radioactive Substance (방사성물질을 이용한 치료의 안전관리 고찰)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Lee, Gui-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.217-224
    • /
    • 2008
  • Is trend that treatment that use isotope of radioactive substance increases from 1964 to now steadily. Bursting tube state solidified accordingly. But, do not establish treatment ward in presence at a sickbed by means that present regulation and system escape this as well as possession that exert negative impact in treatment action preferably is and is treating by radioactivity of small quantity, treatment air by that do not detain many sickers without equaling the institution although there is treatment ward keeps fair death anniversary and is in reservation stand-by status. To possess about 10 therapy rooms including existing sickroom in the institute of nuclear energy recently is looked but is waiting for an opportunity for treatment during suitableness time yet indeed even as that operate 57 radiation isotope therapy rooms all in about 28 hospitals in present domestic state is solveded. Therefore, radiation safety supervision by medical treatment action that treat as radioactive substance may need more active effort. Make mandatory to equipment that hospital which correspond to present the third medical examination and treatment must equip, or effort about more active system improvement may have to be about equipment that enforce this.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Diagnostic Significance of Ultrasonogaphy in Thyroid Nodule (갑상선 결절에서 초음파 촬영의 진단적 의의에 관한 연구)

  • Lee, Myung-Shik;Oh, Yeon-Sang;Lee, Chong-Suk;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Lee, Mun-Ho;Yoon, Jong-Hyun;Kim, Joo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.18 no.1
    • /
    • pp.25-31
    • /
    • 1984
  • The effeciency of combined application of isotope scan and ultrasonography of thyroid was assessed in 91 patients with thyroid nodule. Malignancy rates were 35.5%, 18.8%, & 0% in solid, complex & cystic nodule group, respectively. No statistically significant co-relationship was found between isotope scan finding & ultrasonographic finding. Malignant nodules were found only in cold solid nodule group & cold complex nodule group, and rate of malignant nodule was different between them(45.8% in cold solid nodule group & 20.7% in cold complex nodule group). Difference between the rate of cystic change in benign & malignant nodule observed in our study(59.2% vs. 35.3%) was thought to explain at least partly the statistically different rate of malignant nodule in cold solid nodule & cold complex nodule group. No difference in the boundary condition, echogenicity & distribution of internal echo existed between benign nodule group &malignant nodule group.

  • PDF

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

KCCH Medical Cyclotron Operation for Neutron Therapy and Isotope Production (1989) - A Technical Report - (중성자 치료와 동위원소 생산을 위한 KCCH 의학용 싸이클로트론의 운영 (1989))

  • Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 1990
  • After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.

  • PDF

Development of CCTV Camera in Radiation Environment (방사선 환경내에서의 CCTV 카메라 개발)

  • 소수길;이용범;최영수;김성구;변의교;유승욱;하달규
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.403-406
    • /
    • 1999
  • For a man's approaching limitation in radiation environment, all work must be performed with remoted system to ensure worker's safety and reliability from radiation damage. The remoted system is mostly used in visual observation CCTV system. In high radiation environment of unclear power plant, RI(Radio-isotope) facility, medical radiation treatment facility must be used to radiation tolerant CCTV cameras for radiation damage. We have studied a radiation basic performance of camera components and CCTV cameras to develop radiation tolerant CCTV cameras. As a result, we are able to design a radiation tolerant camera of 108 rad total dose.

  • PDF