• Title/Summary/Keyword: Medical information protection

Search Result 265, Processing Time 0.021 seconds

Gintonin-mediated release of astrocytic vascular endothelial growth factor protects cortical astrocytes from hypoxia-induced cell damages

  • Choi, Sun-Hye;Kim, Hyeon-Joong;Cho, Hee-Jung;Park, Sang-Deuk;Lee, Na-Eun;Hwang, Sung-Hee;Rhim, Hyewon;Kim, Hyoung-Chun;Cho, Ik-Hyun;Nah, Seung-Yeol
    • Journal of Ginseng Research
    • /
    • v.43 no.2
    • /
    • pp.305-311
    • /
    • 2019
  • Background: Gintonin is a ginseng-derived exogenous ligand of the G protein-coupled lysophosphatidic acid (LPA) receptor. We previously reported that gintonin stimulates gliotransmitter release in primary cortical astrocytes. Astrocytes play key roles in the functions of neurovascular systems. Although vascular endothelial growth factor (VEGF) is known to influence the normal growth and maintenance of cranial blood vessels and the nervous system, there is little information about the effect of gintonin on VEGF regulation in primary astrocytes, under normal and hypoxic conditions. Methods: Using primary cortical astrocytes of mice, the effects of gintonin on the release, expression, and distribution of VEGF were examined. We further investigated whether the gintonin-mediated VEGF release protects astrocytes from hypoxia. Results: Gintonin administration stimulated the release and expression of VEGF from astrocytes in a concentration- and time-dependent manner. The gintonin-mediated increase in the release of VEGF was inhibited by the LPA1/3 receptor antagonist, Ki16425; phospholipase C inhibitor, U73122; inositol 1,4,5- triphosphate receptor antagonist, 2-APB; and intracellular $Ca^{2+}$ chelator, BAPTA. Hypoxia further stimulated astrocytic VEGF release. Gintonin treatment stimulated additional VEGF release and restored cell viability that had decreased due to hypoxia, via the VEGF receptor pathway. Altogether, the regulation of VEGF release and expression and astrocytic protection mediated by gintonin under hypoxia are achieved via the LPA receptor-VEGF signaling pathways. Conclusion: The present study shows that the gintonin-mediated regulation of VEGF in cortical astrocytes might be neuroprotective against hypoxic insults and could explain the molecular basis of the beneficial effects of ginseng on the central nervous system.

A Study on the Effects of Risk Factors and Protection Factors of Care givers on Job Change Intention: Focused on the Mediation Effect of Occupational Adaptation (요양보호사의 위험요인과 보호요인이 이직의도에 미치는 영향 연구: 직업적응의 매개효과 중심으로)

  • Park, Su Jan;Kim, Youn Jae
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.2
    • /
    • pp.159-175
    • /
    • 2018
  • The purpose of this study was to identify the factors that could overcome the crisis and adversity of the nursing care provider through understanding the effect of job adaptation on the turnover intention of the nursing care provider and to contribute to the various problems of the nursing care provider in the long term. In order to confirm this as an empirical research task, risk factors and protection factors, general characteristics of the survey subjects, job adaptation and turnover intention were selected, and the risk factors and protective factors of caregivers' As a mediator. So Seoul. The results of the questionnaire survey were as follows: 291 caregivers in the elderly medical welfare facilities in Gyeonggi area. First, as the relationship between the risk factors and protective factors of occupational caregivers and occupational adaptation were more severe, the higher the maladjustment of the workplace culture, the more the job satisfaction and organizational commitment were adversely affected. The emotional support, The higher the information support, the more satisfied and satisfied the job. Second, the relationship between the risk factors of the caregiver and the protective factors and the turnover intention, the higher the conflict of caregivers, the more unstable the workplace, the more difficult it is to adapt to work culture, Respectively. Finally, as a result of verifying the mediating effect of occupational adaptation on the relationship between risk factors and protective factors and turnover intention of caregivers, job satisfaction, which is a sub-factor of job adaptation, It is shown that they play mediating roles only in the relationship between stress and turnover intention, and do not play a mediating role in the relationship between protective factor self - efficacy and social support and turnover intention. In other words, if caregivers feel satisfaction about their job, they can be less stressed on their jobs, improve their self-efficacy, and have a positive attitude toward social support. Also, it was found that the more the caregiver 's immersion into the organization, the less job stress and turnover intention decreased, but the self - efficacy and social support perception were not influenced. Based on this, the director of the facility should strive to stabilize the operation of the facility and provide high-quality services by seeking ways to improve conflict resolution and adaptation to the workplace culture so that nursing care workers can adapt to their work. And it is required to develop active management strategies and institutional support for improving job satisfaction and organizational commitment of caregivers.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Nursing Professor's inspection and Status of Patient's Records and Informed Consent for Clinical Practice of Nursing Student in Korea and Japan (한·일 간호대학생의 임상실습 시 환자의 설명동의 및 기록관리와 지도실태)

  • Cho, Yooh-Yang;Kim, In-Hong;Yamamoto, Fujie;Yamasaki, Fujiko
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.1
    • /
    • pp.35-46
    • /
    • 2006
  • Objectives: In recently. the management and protection on individual information in patient's medical & nursing records have been very important, and that need a guideline. The purpose of this study was to investigate the status of using the patient's nursing records of nursing students in clinical practice, to find and discuss the patient's informed consent, and status of education and management concerned to patient's nursing records. Methods: This study used a mailing survey. data collected from September 24th to October 31th in 2002. The subject were 333 professors who are major in adult nursing, pediatric nursing, psychological nursing of 111 university of nursing department and nursing college. And then we received the survey mail from 103 professors that respondent rate was 30.9%. Results: The characteristics of study subjects showed 49.0% of university. 51.0% of college of nursing. 50.0% of the subjects practiced point the patient by oral approval in clinical practice. But when the decision of the patient was very difficult, 21.6% of the subjects take to informed consent from his or her families. During the clinical practice, 49.0% of the subjects were explain to patient about clinical practice and contents of the nursing student, only 7.8% of the subjects were explain to patient with nursing records. 52.0% of the subjects were took out records from the hospital, only 17.6% of the subjects had standard of the patient's informed consent and standard of handling practice records. 17.6%-92.2% of the subjects that educate and manage concern to patient's nursing records.

  • PDF