• Title/Summary/Keyword: Medical imaging system

Search Result 936, Processing Time 0.028 seconds

Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method (Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가)

  • Park, Ji-Koon;Jung, Bong-Jae;Choi, Jang-Yong;Kang, Sang-Sik
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, an image quality evaluation of amorphous selenium based x-ray system was performed using modulation transfer function (MTF) measurement. MTF as a main factor of imaging quality evaluation was investigated by contrast method from acquired test pattern image. The MTF value was measured to 36.1% at 3.0 lp/mm which is twice as high as that in the film image. Compared with other studies, the results demonstrate that amorphous selenium based x-ray detector is clinically meaningful.

Effects of Decompression Therapy for 6 Cases with Lumbar Herniated Disc (감압치료가 요추간판탈출 6(증)례에 미치는 영향)

  • Kwon, Won-An;Lee, Seung-Ho;Lee, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2133-2141
    • /
    • 2012
  • The Purpose of this study was to report magnetic resonance imaging(MRI) changes of six cases of Lumbar herniated disc which was treated with spinal decompression therapy, oriental medical therapy. 'Disc heights' were measured on sagittal view of $T_2$-weighted MRI. Size of the herniated disc was measured by MRI and 'disc herniations index'. The grading system and algorithm for 'disc degeneration' were based on MRI signal intensity, disc structure, distinction between nucleus and anulus, and disc height. Data for disc height, disc herniations index and disc degeneration grade were collected before and after the treatment together with calculation from the MRI. Case studies were showed that decompression therapy for the herniated disc has an positive effect on disc herniations index, disc regeneration, not disc heights. The clinical evidence for the use of decompression in herniated disc remains inconclusive because of limited researches. Further trials, which give attention to these areas, are needed before any firm conclusions may be made.

Cryo-SEM Methodology of Arabidopsis thaliana Stem Using High-Pressure Freezing (고압동결고정을 이용한 애기장대 줄기의 cryo-SEM 분석법)

  • Choi, Yun-Joung;Lee, Kyung-Hwan;Je, A-Reum;Chae, Hee-Su;Jang, Ji-Hoon;Lee, Eun-Ji;Kweon, Hee-Seok
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.111-114
    • /
    • 2012
  • The scanning electron microscopy is an ideal technique for examining plant surface at high resolution. Most hydrate samples, however, must be fix and dehydrate for observation in the scanning electron microscope. Because the microscopes operate under high vacuum, most specimens, especially biological samples, cannot withstand water removal by the vacuum system without morphological distortion. Cryo-techniques can observe in their original morphology and structure without various artifacts from conventional sample preparation. Rapid cooling is the method of choice for preparing plant samples for scanning electron microscopy in a defined physiological state. As one of cryo-technique, high-pressure freezing allows for fixation of native non-pretreated samples up to $200{\mu}M$ thick and 2 mm wide with minimal or no ice crystal damage for the freezing procedure. In this study, we could design to optimize structural preservation and imaging by comparing cryo-SEM and convention SEM preparation, and observe a fine, well preserved Arabidopsis stem's inner ultrastructure using HPF and cryo-SEM. These results would suggest a useful method of cryo-preparation and cryo-SEM for plant tissues, especially intratubule and vacuole rich structure.

Three Dimensional Shape Estimation by Shading Analysis of Endoscopic Image (음영분석에 의한 내시경 영상의 3차원 형체 추정에 관한 연구)

  • Lee, Tae-Su;Cha, Eun-Jong;Yun, Se-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.499-506
    • /
    • 1995
  • A new numerical method estimated three dimensional shape of the internal surface of the stomach by analyzing the shading data of endoscopic image. First analyzed was the inherent instrumentational characteristics of the endoscope system, followed by the analysis of the stomach surface properties, both of which affected the imaging properties. We employed these prior informations to implement the iterative algorithm of shading analysis based on Hom's variational approach. The present algorithm was validated by performing simulation on a $256{\times}320$ image data chosen from original $512{\times}512$ image of the stomach surface model. The best 3-dimensional estimation of the surface was achieved with the Lagrangian multiplier, of 0.3, when the algorithm best converged showing minimal estimation error.

  • PDF

Safety Evaluation of Iopamidol Contrast Medium Used for Radiological Examination of a Local Clinic in Korea (방사선 검사에 사용되는 조영제 Iopamidol의 안전성 평가)

  • Park, Chang-Mook;Lee, Bo-Reum;Song, Tea-Bum;Jang, Je-Kwan;Lee, Yu-Jeung;Lee, Myung-Koo;Lim, Sung-Cil
    • YAKHAK HOEJI
    • /
    • v.53 no.6
    • /
    • pp.328-333
    • /
    • 2009
  • Contrast media are substances that are used to enhance the contrast of structures or fluids within the body in medical imaging. Those are commonly used to enhance the visibility of blood vessels and the gastrointestinal tract. The aim of this study is to evaluate patients who got injected iopamidol, developed as one of contrast medium regarding changes in cardiovascular system and especially, adverse drug reactions. This study were performed on randomly selected a total of 51 patients (range of 15~85 years old) who got injected contrast medium, Iopamidol at a P hospital in Gyeonggi province from September 22nd, 2008 to January 24th, 2009. Data were collected by questionnaire though person to person. We analyzed the data by SPSS (Version 12. for windows). Methods of analysis were frequency and cross analysis. In results, 19.6% (n=10) were founded for adverse drug reactions of contrast medium. 25.0% (n=4) of 10 patients who had adverse drug reactions of contrast medium had took abdomen contrast test. 2 patients of those took contrast test for chest. Also, 3.9% (n=2) patients felt vomiting and nausea after injection of contrast medium. In conclusion, 19.6% patients experienced adverse drug reaction of contrast medium. Therefore, when taking radiation test, we should make efforts to minimize adverse drug reactions to achieve suitable and effective treatment.

3D Head Modeling using Depth Sensor

  • Song, Eungyeol;Choi, Jaesung;Jeon, Taejae;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.13-16
    • /
    • 2015
  • Purpose We conducted a study on the reconstruction of the head's shape in 3D using the ToF depth sensor. A time-of-flight camera (ToF camera) is a range imaging camera system that resolves distance based on the known speed of light, measuring the time-of-flight of a light signal between the camera and the subject for each point of the image. The above method is the safest way of measuring the head shape of plagiocephaly patients in 3D. The texture, appearance and size of the head were reconstructed from the measured data and we used the SDF method for a precise reconstruction. Materials and Methods To generate a precise model, mesh was generated by using Marching cube and SDF. Results The ground truth was determined by measuring 10 people of experiment participants for 3 times repetitively and the created 3D model of the same part from this experiment was measured as well. Measurement of actual head circumference and the reconstructed model were made according to the layer 3 standard and measurement errors were also calculated. As a result, we were able to gain exact results with an average error of 0.9 cm, standard deviation of 0.9, min: 0.2 and max: 1.4. Conclusion The suggested method was able to complete the 3D model by minimizing errors. This model is very effective in terms of quantitative and objective evaluation. However, measurement range somewhat lacks 3D information for the manufacture of protective helmets, as measurements were made according to the layer 3 standard. As a result, measurement range will need to be widened to facilitate production of more precise and perfectively protective helmets by conducting scans on all head circumferences in the future.

The Study on the Superconducting MRI Magnet of 68 cm in Room Temperature Bore (68 cm 상온 보아를 갖는 MRI용 초전도마그네트에 관한 연구)

  • Jin, H.B.;Oh, B.H.;Cho, J.W.;Oh, S.S.;Kwon, Y.K.;Ha, D.W.;Lee, E.Y.;Kim, H.J.;Kim, O.K.;Choi, B.J.;Ryu, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.142-146
    • /
    • 1996
  • In this paper, we present the main research results on the 2 Tesla class - superconducting MRI magnet which we have developed. Multi section type superconducting MRI main coil and various superconducting shims were designed and fabricated for obtaining the high field homogeneity, which is requested in the MR imaging. After assembling the magnet with room temperature bore cryostat field homogenity has been measured and analyzed by NMR field mapping system. According to this, field homogeneity of 22 ppm / 30 cm dsv was confirmed.

  • PDF

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.

Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography (간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Prospective Multicenter Feasibility Study of Laparoscopic Sentinel Basin Dissection after Endoscopic Submucosal Dissection for Early Gastric Cancer: SENORITA 2 Trial Protocol

  • Eom, Bang Wool;Yoon, Hong Man;Min, Jae Seok;Cho, In;Park, Ji-Ho;Jung, Mi Ran;Hur, Hoon;Kim, Young-Woo;Park, Young Kyu;Nam, Byung-Ho;Ryu, Keun Won;Sentinel Node Oriented Tailored Approach (SENORITA) Study Group
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.157-164
    • /
    • 2019
  • Purpose: Although standard radical gastrectomy is recommended after noncurative resection of endoscopic submucosal dissection (ESD) for early gastric cancer in most cases, residual tumor and lymph node metastasis have not been identified after surgery. The aim of this study is to evaluate the feasibility of sentinel node navigation surgery after noncurative ESD. Materials and Methods: This trial is an investigator-initiated, multicenter prospective phase II trial. Patients who underwent ESD for clinical stage T1N0M0 gastric cancer with noncurative resections were eligible. Qualified investigators who completed the prior phase III trial (SENORITA 1) are exclusively allowed to participate. In this study, 2 detection methods will be used: 1) intraoperative endoscopic submucosal injection of dual tracer, including radioisotope and indocyanine green (ICG) with sentinel basins detected using gamma-probe; 2) endoscopic injection of ICG, with sentinel basins detected using a fluorescence imaging system. Standard laparoscopic gastrectomy with lymphadenectomy will be performed. Sample size is calculated based on the inferior confidence interval of the detection rate of 95%, and the calculated accrual is 237 patients. The primary endpoint is detection rate, and the secondary endpoints are sensitivity and postoperative complications. Conclusions: This study is expected to clarify the feasibility of laparoscopic sentinel basin dissection after noncurative ESD. If the feasibility is demonstrated, a multicenter phase III trial will be initiated to compare laparoscopic sentinel node navigation surgery versus laparoscopic standard gastrectomy in early gastric cancer after endoscopic resection.