• Title/Summary/Keyword: Medical image transmission

Search Result 126, Processing Time 0.025 seconds

Performance Evaluation of Medical Image Transmission System using TH UWB-IR Technology

  • Lee, Yang-Sun;Kang, Heau-Jo
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.3
    • /
    • pp.97-100
    • /
    • 2006
  • In this paper, the transmission service for medical image is proposed via IEEE 802.15.4a on WPAN environment. Also, transmission and receiving performance of medical image using TH UWB-IR system is evaluated on indoor multi-path fading environment. On the results, the proposed scheme can solve the problem of interference from the medical equipment in same frequency band, and minimize the loss due to the indoor multi-path fading environment. Therefore, the transmission with low power usage is possible.

Development of Medical Picture Archiving and Communication System (의료용 화상정보의 저장 및 전송 시스템 개발)

  • 이태수;백승권
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.195-210
    • /
    • 1988
  • We build up distributed database of medical picture and design and realize H/W & S/W of special image workstation. We build up high speed image transmission system for distributed database and retrieval of various medical pictures in w ard through image transmission system and realize integrated image diagnosis. This system improves medical service by speedy diagnosis and enables more precise diagnosis by integrated image diagnosis through distributed database. In economical view this system curtails huge cost of film processing and transmission, which make medical expense cheaf, because it does not use film. We built up PACS in pediatric hospital of Seoul National University Hopital and tested the system with various medical pictures and showed that speedy integrated image diagnosis is possible.

  • PDF

A Study on the Development of PC-card for Information Transmission of Medical Image in the Environment of ISDN(Intergrated Service Digital Network) (종합정보통신망 환경속에서 의료 영상정보 전달을 위한 PC-card 개발에 관한 연구)

  • 이동화;임춘성
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.243-248
    • /
    • 1991
  • This paper described the implementation of high speed transmission fort medical image between hospitals using ISDN. The implemented system, called PC-card, can transmit datas as 144Kbps and can install in the personal computer. So, this enables to get more reliable medical image with less cost, and to service the better quality for an unurbanized area. In this system, installing in the PC system were enhanced to input from medical image system and output to the memory or display

  • PDF

A comparative study of medical image applications: compression and transmission

  • Cho, Kyu-Cheol;Kim, Jae-Joon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.5
    • /
    • pp.14-22
    • /
    • 2007
  • PACS is an integrated communication network system which is consists of image acquisition devices, storage archiving units, display stations, computer processors, and database management systems. In medical industry, they have been introduced the medical equipments through PACS systems based on the DICOM standard. In this paper, we have reviewed the visual quality performance of various JPEG and JPEG2000 compression options for medical images. Through the realized the transmission mode on DICOM standard, the developed DICOM viewer has been shown in medical applications.

  • PDF

A Study on the TH UWB-IR Medical Image Transmission System using the IEEE 802.15.4a (IEEE 802.15.4a를 활용한 TH UWB-IR 의료영상 전송 시스템에 관한 연구)

  • Lee, Yang-Sun;Kang, Heau-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.1954-1959
    • /
    • 2006
  • In this paper, we proposed TH UWB-IR medical image transmission system using the IEEE an. 802.15.4a specification in WPAN environment. Also, we analyzed reception performance of wireless medical image transmission system in indoor multi-path fading environment using ITU-R M.1225 channel model. As a results, the proposed scheme can solve the problem of interference from the medical equipment in same frequency band, and minimize the loss due to the indoor multi-path fading environment. Therefore, the transmission with low power usage is possible.

Encryption-based Image Steganography Technique for Secure Medical Image Transmission During the COVID-19 Pandemic

  • Alkhliwi, Sultan
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.3
    • /
    • pp.83-93
    • /
    • 2021
  • COVID-19 poses a major risk to global health, highlighting the importance of faster and proper diagnosis. To handle the rise in the number of patients and eliminate redundant tests, healthcare information exchange and medical data are transmitted between healthcare centres. Medical data sharing helps speed up patient treatment; consequently, exchanging healthcare data is the requirement of the present era. Since healthcare professionals share data through the internet, security remains a critical challenge, which needs to be addressed. During the COVID-19 pandemic, computed tomography (CT) and X-ray images play a vital part in the diagnosis process, constituting information that needs to be shared among hospitals. Encryption and image steganography techniques can be employed to achieve secure data transmission of COVID-19 images. This study presents a new encryption with the image steganography model for secure data transmission (EIS-SDT) for COVID-19 diagnosis. The EIS-SDT model uses a multilevel discrete wavelet transform for image decomposition and Manta Ray Foraging Optimization algorithm for optimal pixel selection. The EIS-SDT method uses a double logistic chaotic map (DLCM) is employed for secret image encryption. The application of the DLCM-based encryption procedure provides an additional level of security to the image steganography technique. An extensive simulation results analysis ensures the effective performance of the EIS-SDT model and the results are investigated under several evaluation parameters. The outcome indicates that the EIS-SDT model has outperformed the existing methods considerably.

HIERARCHICAL STILL IMAGE CODING USING MODIFIED GOLOMB-RICE CODE FOR MEDICAL IMAGE INFORMATION SYSTEM

  • Masayuki Hashimoto;Atsushi Koike;Shuichi Matsumoto
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.97.1-102
    • /
    • 1999
  • This paper porposes and efficient coding scheme for remote medical communication systems, or“telemedicine systems”. These systems require a technique which is able to transfer large volume of data such as X-ray images effectively. We have already developed a hierarchical image coding and transmission scheme (HITS), which achieves an efficient transmission of medical images simply[1]. In this paper, a new coding scheme for HITS is proposed, which used hierarchical context modeling for the purpose of improving the coding efficiency. The hierarchical context modeling divides wavelet coefficients into several sets by the value of a correspondent coefficient in their higher class, or“a parent”, optimizes a Golomb-Rice (GR) code parameter in each set, and then encodes the coefficients with the parameter. Computer simulation shows that the proposed scheme is effective with simple implementation. This is due to fact that a wavelet coefficient has dependence on its parent. As a result, high speed data transmission is achieved even if the telemedicine system consists of simple personal computers.

Development of 32-Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 32채널 영상획득장치 개발)

  • 양근호;유병국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.110-113
    • /
    • 2003
  • In this paper, the multi-channel high speed data acquisition system is implemented. This high speed signal processing system for 3-D image display is applicable to the manipulation of a medical image processing, multimedia data and various fields of digital image processing. In order to convert the analog signal into digital one, A/D conversion circuit is designed. PCI interface method is designed and implemented, which is capable of transmission a large amount of data to computer. In order to, especially, channel extendibility of images acquisition, bus communication method is selected. By using this bus method, we can interface each module effectively. In this paper, 32-channel A/D conversion and PCI interface system for 3-dimensional and real-time display of the retina image is developed. The 32-channel image acquisition system and high speed data transmission system developed in this paper is applicable to not only medical image processing as 3-D representation of retina image but also various fields of industrial image processing in which the multi-point realtime image acquisition system is needed.

  • PDF

A Development of a Medical Information Transmisson System in Moving Picture Form(MedMpeg)

  • Choi, Jong U.;Cho, Hune
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.2 no.1
    • /
    • pp.131-139
    • /
    • 1998
  • With the rapid development of communication technology and widespread uses of internet service, utilization of internet-based medical information systems which transmitts moving pictures of medical objects is becoming a common practice. The internet-based medical information service prvovides richer information than conventional services such as touch-tone telephone, personal computers e-mails, or pagers, because "a picture is worth a thousand words". However, the systems passively transmits moving pictures of the medical objects to the users, and thus the system cannot intelligently adjust itself to provide better service. As the tradeoff exists between transmission speed and quality of the image, there is a need that moving pictures be analyzed to adjust the trnasmission speed and image quality. When very little difference between consecutive images are detected, the system can automatically increase the size of the image files, thus enhancing the quality of image. In contrast, the system should increase the number of images to send more pictorial information by sacrificing the quality of each individual image, when a significant difference is detected. In this paper an adaptive filtering technique is introduced which adjusts the quality of image and transmission speed according to a clinical situation in hospital.

  • PDF

Various Image Compression using Medical Image and Analysis for Compression Ratio (의료영상을 이용한 다양한 압축방법의 구현 및 압축율 비교.분석)

  • 추은형;김현규;박무훈
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.185-188
    • /
    • 2002
  • With improved network system and development of computer technology, a lot of hospitals are equipping PACS that deals with process and transmission of the medical images. Owing to equipment of PACS the problems on transmission and storage of the medical images were treated. The way to solve the problems is to use various image processing techniques and compression methods This paper describes RLC in lossless image compression method, JPEG using DCT in loss image compression applied to medical images as way implementing DICOM standard. Now the medical images were compressed with Wavelet transform method have been taken advantage of image process. And compression rate of each compression methods was analyzed.

  • PDF