• Title/Summary/Keyword: Medical image communication

Search Result 270, Processing Time 0.026 seconds

A study on the Identity design factors of dermatologic clinic linked with aesthetic space (에스테틱과 연계된 피부과의원의 디자인 아이덴티티 요소에 관한 연구)

  • Ju, Hye-Ra;Kim, Young-Hoon;So, Hyun-A
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.4
    • /
    • pp.124-131
    • /
    • 2009
  • The aesthetics of current dermatology clinics are the main space of dermatology, which is gradually becoming an area of specialty. Paths requiring spatial transition due to the expansion of treatment field in dermatology clinics are currently emerging, meaning that the duty to provide medical and aesthetic environment with high spatial connection must be accompanied. Contrary to past clinics where only functional aspects were emphasized, current clinics require a differentiated environment that considers both aspects of function and aesthetics, centered on the patient. The purpose of this research in this perspective is to study the efficient connection between dermatology and aesthetics, while also analyzing identity factors to indicate design factors differentiated from other functional spaces, to apply them as preliminary data for the planning of dermatology clinics. Based on the above, six dermatology clinics located in Seoul were designated for case studies through field studies. Overall, Aesthetics connected to dermatology clinics legally must have separate business registrations and have alternative entrance ways. Currently however, there were many cases where entrance, waiting, reception and receipt were not separated. there were efforts to partially display identities when analyzing design factors that formed the identity of dermatology clinics. However, there were insufficient cases where visual communication factors such as a clinic's spatial identity, logo, signing system, and applied products were integrated into a coherent theme. At this point when dermatology clinics are becoming brands, all fields must merge for integrated identity effects that go beyond the boundaries of contemporary H.I, to clearly display their identity with the clinics' professional image and consistent concept.

Fractal Image Coding for Improve the Quality of Medical Images (의료영상의 화질개선을 위한 프랙탈 영상 부호화)

  • Park, Jaehong;Park, Cheolwoo;Yang, Wonseok
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2014
  • This paper suggests techniques to enhance coding time which is a problem in traditional fractal compression and to improve fidelity of reconstructed images by determining fractal coefficient through adaptive selection of block approximation formula. First, to reduce coding time, we construct a linear list of domain blocks of which characteristics is given by their luminance and variance and then we control block searching time according to the first permissible threshold value. Next, when employing three-level block partition, if a range block of minimum partition level cannot find a domain block which has a satisfying approximation error, we choose new approximation coefficients using a non-linear approximation of luminance term. This boosts the fidelity. Our experiment employing the above methods shows enhancement in the coding time more than two times over traditional coding methods and shows improvement in PSNR value by about 1-3dB at the same compression rate.

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

Design and manufacture of eyeball protrusion measuring device using white light scanning interferometer (백색광 간섭계를 이용한 안구 돌출 측정 장치 설계 및 제작)

  • Chang, Jung-soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2019
  • The relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure eyeball protrusion values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In this paper, we designed and fabricated a protrusion measuring device using a white light interferometer and measured the protrusion of the human eye and found that the precision and repeatability were significantly higher than the manual measurement method.

A Survey of Operation and Development Direction in KPNFA (KPNFA 운영 및 발전 방향 모색을 위한 설문조사 연구)

  • Lim, Jae-Heon;Na, Eun-Jin;Lee, Moon-Kyu
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.377-388
    • /
    • 2018
  • Purpose: The purpose of this study was to survey the operation and development direction in KPNFA. Method: The participants of this study consisted of physical therapists who had a KPNFA membership. The satisfaction levels for each item (KPNFA impression, educational programs, and clinical application) were measured using a 5-point Likert scale. The survey was performed during June and July 2018. The total questionnaire was comprised of 648 samples. For the data analysis, descriptive statistics and Spearman correlation analysis were used to compare the general characteristics and all items. Results: In the questionnaire, the impression of KPNFA was 69.21, the instructor specialization in the educational programs was 74.22, and helpful interventions for clinical application scored 74.96. KPNFA's image is competitive; friendly items scored the highest, and operation suitability and communication scored the lowest. The most important factor of the educational program was the quality of the instructors. The most helpful item was the education intervention program. The nervous system was applied to the patient with the highest response. The age of subjects showed a significant positive correlation with KPNFA impression, KPNFA branch impression, and branch problem solving. The work duration of subjects showed a significant negative correlation with instructor specialization. A regular member duration of subjects showed a negative correlation with teaching method, instructor specialization. Conclusions: The KPNFA survey was performed for the first time. In the future, this data will be utilized as the basis for KPNFA policy.

Efficient Deep Neural Network Architecture based on Semantic Segmentation for Paved Road Detection (효율적인 비정형 도로영역 인식을 위한 Semantic segmentation 기반 심층 신경망 구조)

  • Park, Sejin;Han, Jeong Hoon;Moon, Young Shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1437-1444
    • /
    • 2020
  • With the development of computer vision systems, many advances have been made in the fields of surveillance, biometrics, medical imaging, and autonomous driving. In the field of autonomous driving, in particular, the object detection technique using deep learning are widely used, and the paved road detection is a particularly crucial problem. Unlike the ROI detection algorithm used in general object detection, the structure of paved road in the image is heterogeneous, so the ROI-based object recognition architecture is not available. In this paper, we propose a deep neural network architecture for atypical paved road detection using Semantic segmentation network. In addition, we introduce the multi-scale semantic segmentation network, which is a network architecture specialized to the paved road detection. We demonstrate that the performance is significantly improved by the proposed method.

Development of X-Ray Array Detector Signal Processing System (X-Ray 어레이 검출 모듈 신호처리 시스템 개발)

  • Lim, Ik-Chan;Park, Jong-Won;Kim, Young-Kil;Sung, So-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1298-1304
    • /
    • 2019
  • Since the 9·11 terror attack in 2001, the Maritime Logistics Security System has been strengthened and required X-ray image for every imported cargos from manufacturing countries to United States. For scanning cargos, the container inspection systems use high energy X-rays for examination of contents of a container to check the nuclear, explosive, dangerous and illegal materials. Nowadays, the X-ray cargo scanners are established and used by global technologies for inspection of suspected cargos in the customs agency but these technologies have not been localized and developed sufficiently. In this paper, we propose the X-ray array detector system which is a core component of the container scanning system. For implementation of X-ray array detector, the analog and digital signal processing units are fabricated with integrated hardware, FPGA logics and GUI software for real-time X-ray images. The implemented system is superior in terms of resolution and power consumption compared to the existing products currently used in ports.

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Design of a CMOS x-ray line scan sensors (CMOS x-ray 라인 스캔 센서 설계)

  • Heo, Chang-Won;Jang, Ji-Hye;Jin, Liyan;Heo, Sung-Kyn;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2369-2379
    • /
    • 2013
  • A CMOS x-ray line scan sensor which is used in both medical imaging and non-destructive diagnosis is designed. It has a pixel array of 512 columns ${\times}$ 4 rows and a built-in DC-DC converter. The pixel circuit is newly proposed to have three binning modes such as no binning, $2{\times}2$ binning, and $4{\times}4$ binning in order to select one of pixel sizes of $100{\mu}m$, $200{\mu}m$, and $400{\mu}m$. It is designed to output a fully differential image signal which is insensitive to power supply and input common mode noises. The layout size of the designed line scan sensor with a $0.18{\mu}m$ x-ray CMOS image sensor process is $51,304{\mu}m{\times}5,945{\mu}m$.