• Title/Summary/Keyword: Medical errors

Search Result 568, Processing Time 0.021 seconds

ACCURACY TESTS OF 3D RAPID PROTOTYPING (RP) MEDICAL MODELS: ITS POTENTIAL AND CLINICAL APPLICATIONS (Rapid Prototyping으로 제작한 3D Medical Model의 오차 측정에 관한 연구 (임상 적용 가능성 및 사례))

  • Choi, Jin-Young;Choi, Jung-Ho;Kim, Nam-Kuk;Lee, Jong-Ki;Kim, Myeng-Ki;Kim, Myung-Jin;Kim, Yeong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.295-303
    • /
    • 1999
  • Presented in this paper are the experimental results that measure rapid prototyping (RP) errors in 3D medical models. We identified various factors that can cause dimensional errors when producing RP models, specifically in maxillofacial areas. For the experiment, we used a human dry skull. A number of linear measurements based on landmarks were first obtained on the skull. This was followed by CT scanning, 3D model reconstruction, and RP model fabrication. The landmarks were measured again on both the reconstructed models and the physical RP models, and these were compared with those on dry skull. We focused on major sources of errors, such as CT scanning, conversion from CT data to STL models, and RP model fabrication. The results show that the overall error from skull to RP is $0.64{\times}0.36mm(0.71{\times}0.66%)$ in absolute value. This indicates that the RP technology can be acceptable in the real clinical applications. A clinical case that has applied RP models successfully for treatment planning and surgical rehearsal is presented. Although the use of RP models is rare in the medical area yet, we believe RP is promising in that it has a great potential in developing new tools which can aid diagnosis, treatment planning, surgical rehearsal, education, and so on.

  • PDF

Epidemiological Survey on Mass Screening for Inborn Errors of Metabolism (한국의 신생아에서 선천성 대사이상 Screening에 관한 역학조사)

  • Lee, Jae-Sang;Choi, Cheol-Seok;Choi, Kyu-Soon;Lee, Mu-Ju;Doo, Hwa-Sun;Kang, Sang-Hoon
    • The Journal of the Korean life insurance medical association
    • /
    • v.18
    • /
    • pp.107-110
    • /
    • 1999
  • The disorders of congenital metabolic errors causing mental retardation can be prevented by early diagnosis and treatment. We analysed 144,000 neonatal blood samples for phenyketonuria(PKU), maple syrup urine disease(MSUD), homocystinuria(HCU) and histidinuria(HE) by bacterial inhibition method, and galactosemia(GAL) by Paigen method. In our survey, the positive were 4 samples in PKU(4mg/dl;2, 6mg/dl;1, 8mg/dl;1), 8 samples in MSUD(4mg/dl;2, 6mg/dl;2, 8mg/dl;3, 10mg/dl;1), 4 samples in HCU(4mg/dl;2, 6mg/dl;2), 4 samples in Galactosemia(4mg/dl;2, 6mg/dl;1, 8mg/dl;1), respectively. while, no one was positive in HE. The frequncy rate were 1/36,000 for PKU, HCU and GAL, 1/18,000 for MSUD, respectively. But those for HE couldn't be detected in our survey. In this study, the hightest frequency rate was 1/18,000 of MSUD, following were 1/36,000 for PKU, HCU and GAL, respectively. As results our data, it is our opinion that neonatal screening should be performed in terms of national policies for ealy diagnosis and theraphy.

  • PDF

Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm (Analytical Anisotropic Algorithm을 사용한 폐암 치료 시 MU 검증 프로그램 적용에 관한 고찰)

  • Kim, Jong-Min;Kim, Dae-Sup;Hong, Dong-Ki;Back, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose: There was a problem with using MU verification programs for the reasons that there were errors of MU when using MU verification programs based on Pencil Beam Convolution (PBC) Algorithm with radiation treatment plans around lung using Analytical Anisotropic Algorithm (AAA). On this study, we studied the methods that can verify the calculated treatment plans using AAA. Materials and Methods: Using Eclipse treatment planning system (Version 8.9, Varian, USA), for each 57 fields of 7 cases of Lung Stereotactic Body Radiation Therapy (SBRT), we have calculated using PBC and AAA with dose calculation algorithm. By developing MU of established plans, we compared and analyzed with MU of manual calculation programs. We have analyzed relationship between errors and 4 variables such as field size, lung path distance of radiation, Tumor path distance of radiation, effective depth that can affect on errors created from PBC algorithm and AAA using commonly used programs. Results: Errors of PBC algorithm have showned $0.2{\pm}1.0%$ and errors of AAA have showned $3.5{\pm}2.8%$. Moreover, as a result of analyzing 4 variables that can affect on errors, relationship in errors between lung path distance and MU, connection coefficient 0.648 (P=0.000) has been increased and we could calculate MU correction factor that is A.E=L.P 0.00903+0.02048 and as a result of replying for manual calculation program, errors of $3.5{\pm}2.8%$ before the application has been decreased within $0.4{\pm}2.0%$. Conclusion: On this study, we have learned that errors from manual calculation program have been increased as lung path distance of radiation increases and we could verified MU of AAA with a simple method that is called MU correction factor.

  • PDF

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Usefulness of Manual Analysis of Bone Mineral Density Using Dual Energy X-ray Absorptiometry (이중에너지엑스선흡수기(Dual energy X-ray Absorptiometry: DXA)를 이용한 골밀도검사 결과분석에서 수동분석법의 유용성 평가)

  • Kim, Eun Hye;Kwak, Jong Gil;Kim, Ho Sung
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.317-324
    • /
    • 2018
  • The results of bone mineral density analysis using DXA were compared between automatic and manual methods. The purpose of this paper is to verify the range of errors of each analysis method in the same patient and select a proper method to minimize errors. Comparisons between automatic and manual analysis methods were made using BMD, BMC and AREA. Basal and follow up examinations were performed with the patients of normal, osteopenia and osteoporosis. In the basal examinations, the precision errors between automatic and manual method showed 1.9% in normal, 3.1% in osteopenia and 3.8% in osteoporosis. In case of follow up studies, the precision errors between automatic and manual method showed 2.3% in normal, 3.2% in osteopenia and 3.5% in osteoporosis. BMC and AREA also showed a tendency to increase precision errors on osteopenia and osteoporosis. Therefore, a manual method would be a better option to minimize errors in patients with osteopenia and osteoporosis.

Analysis of Effects of Chemotherapy using Failure Mode and Effect Analysis (FMEA) on Patient Safety and Safe Nursing (고장유형영향분석을 활용한 항암화학요법의 환자안전간호 효과분석)

  • Yang, Nam Young;Lee, Mi Hyang
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.21 no.3
    • /
    • pp.254-262
    • /
    • 2015
  • Purpose: This study was done to apply failure mode & effect analysis (FMEA) to chemotherapy in order to reduce prescribing, dispensing and administering errors related to treatment and provide patients with a safe medical environment. Methods: A one group pre-post test design was used to verify the effects using the tool for FMEA in chemotherapy. Results: There was a statistically significant decrease in prescribing errors from 11.47% to 3.18%; administering errors decreased but they were not statistically significant. In a addition, there was no change in dispensing errors. Conclusion: The results show that FMEA removed risk factors that might occur during the process of chemotherapy and that it was an effective tool for prevention of negligent accident occurring in actual patients.

Human Error Analysis in a Permit to Work System: A Case Study in a Chemical Plant

  • Jahangiri, Mehdi;Hoboubi, Naser;Rostamabadi, Akbar;Keshavarzi, Sareh;Hosseini, Ali Akbar
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • Background: A permit to work (PTW) is a formal written system to control certain types of work which are identified as potentially hazardous. However, human error in PTW processes can lead to an accident. Methods: This cross-sectional, descriptive study was conducted to estimate the probability of human errors in PTWprocesses in a chemical plant in Iran. In the first stage, through interviewing the personnel and studying the procedure in the plant, the PTW process was analyzed using the hierarchical task analysis technique. In doing so, PTWwas considered as a goal and detailed tasks to achieve the goal were analyzed. In the next step, the standardized plant analysis risk-human (SPAR-H) reliability analysis method was applied for estimation of human error probability. Results: The mean probability of human error in the PTW system was estimated to be 0.11. The highest probability of human error in the PTW process was related to flammable gas testing (50.7%). Conclusion: The SPAR-H method applied in this study could analyze and quantify the potential human errors and extract the required measures for reducing the error probabilities in PTW system. Some suggestions to reduce the likelihood of errors, especially in the field of modifying the performance shaping factors and dependencies among tasks are provided.

The Application of Paewinsky et al.'s Age Estimation Method to Periapical Radiographs (치근단 방사선 사진에서 Paewinsky 연령추정법 적용에 대한 연구)

  • Roh, Byung-Yoon;Seo, Jeong-Uk;Kim, Chang-Gyum;Choi, Chang-Un;Lee, Won-Joon;Lee, Sang-Seob
    • The Korean Journal of Legal Medicine
    • /
    • v.42 no.4
    • /
    • pp.141-145
    • /
    • 2018
  • There have been many radiographic studies on age estimation that evaluate reduction in size of dental pulp cavity with secondary dentin formation. The Paewinsky method reported high accuracy in estimating ages by measuring the width of the pulp cavity in panoramic radiographs. The aim of this study was to evaluate the application of the Paewinsky method to digital periapical radiographs. This study was conducted on 103 cases that reported to the Section of Human Identification of the National Forensic Service. The age was calculated by applying the Paewinsky method that measures the root and pulp canal width at three points in a tooth. The estimation results were compared with those calculated by the Johanson method. When the Paewinsky models were applied to digital periapical radiographs, the errors were significantly greater as compared to the original study. The errors of the maxillary second premolar and mandibular lateral incisor were greater than those of the maxillary central incisor, lateral incisor, mandibular canine, and first premolar. Furthermore, errors of the age estimation models in level C were greater than those in levels A and B. This study could be a reference for the application of the Paewinsky method to digital periapical radiographs.

Image-Guided Radiotherapy for Target Localization in Prostate Cancer with Implanted Markers

  • Suh, Ye-Lin;Park, Sung-Ho;Ahn, Seung-Do;Kim, Jong-Hoon;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.68-70
    • /
    • 2005
  • To precisely localize target in prostate cancer, image-guided radiotherapy was performed using the $ExacTrac^{\circledR}$ x-ray system (Brainlab, Germany) with implanted markers. For three prostate cancer patients, three gold markers were implanted into prostate. Orthogonal portal images were acquired every treatment and CT scans were repeated 3~5 times during the course of treatment. After correcting setup errors calculated by the system, the position of the implanted markers and the distance between them were detected in daily portal images and in CT images, and analyzed retrospectively. Deviation of the relative position of the implanted markers and the distance between them were less than 1 mm in lateral, longitudinal, and vertical direction for three patients, both in portal images and CT images. This study reveals that image-guided radiotherapy using the $ExacTrac^{\circledR}$ system is useful to verify positioning errors and localize prostate target with implanted markers, reducing the planning target volume (PTV) margin as well as irradiation to rectum and bladder.

  • PDF

Association of Sleep Characteristics with Medication Errors for Shift Work Nurses in Intensive Care Units (중환자실 교대근무간호사의 수면특성과 투약오류와의 관계)

  • Yi, Young Hee;Choi, Su Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.4
    • /
    • pp.403-412
    • /
    • 2014
  • Purpose: Shift work disrupts the synchronization between the human biological clock and the environment. Sleep disturbances are common for shift work nurses, and may threaten patient safety. This study was done to investigate the sleep characteristics and medication errors (ME) of intensive care unit (ICU) nurses who work shifts, and ascertain if there is an association between these factors. Methods: Data were collected using a self-report questionnaire from 126 ICU nurses on three shifts. Collected data included their sleep characteristics including sleep patterns and sleep disturbances, and ME for the past 2 weeks. Results: There were significant differences in sleep duration and sleep latency according to shift. Day shift nurses had the shortest sleep duration, and their sleep latency was the longest (about 49 minutes) compared to nurses on evening and night shifts; 54% reported sleep disturbances, 16% experienced ME, and among these nurses 50% were on the night shift. Logistic regression analysis revealed significant associations between nurses' sleep duration and ME (adjusted OR 0.52 [95% CI 0.32-0.85]). Conclusions: The results confirmed that shift work nurses in the ICUs experience sleep disturbance, and that less sleep is associated with ME.