A Study on the Change of Bone Mineral Density(BMD) by Life Habit and Physical Condition (성인의 신체조건 및 생활습관에 따른 골밀도 변화에 대한 연구)

  • Kim, Sun-Geun
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.177-184
    • /
    • 2006
  • Purpose: To evaluate the correlation between BMD and life habit such as drinking. exercise smoking or physical condition such as age, sex, height, weight, body mass index(BMI). Materials and Methods: I evaluated the BMD of the femoral neck and L2-L4 spines of 321 persons who took a regular health screening in Woosuk university oriental medical hospital from February to April in 2006 by dual energy bone mineral densitometry. Results: The age of persons ranged from 20 years to 75 years(mean $45.10{\pm}11.54$) and there were 160 males and 161 females. In males, BMD of the femoral head was highest at 2nd decade, BMD of the spine was highest at 4th decade, and BMD of both femoral head and lumbar spine was lowest at 6th decade. In fenales, BMD of both femoral head and lumbar spine was highest at 4th decade and lowest at 6th decade. Among the various physical conditions, only height of persons showed significant correlation with BMD in both males and females. BMD was increased according to increasing height. In males, BMD of persons who had habit such as drinking, exercise or smoking did not show significant change statistically. But in females, drinking group showed high BMD relative to non-drinking group in both femoral head and lumbar spine. Conclusion: BMD was different according to age, sex, height and life habit. Especially aged people showed osteoporotic change progressively. More persistent effort is needed to find out the factors decreasing BMD for prevention of problems by osteoporosis.

  • PDF

Three Dimensional Target Volume Reconstruction from Multiple Projection Images (다중투사영상을 이용한 표적체적의 3차원 재구성)

  • 정광호;진호상;이형구;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • In the radiation treatment planning (RTP) process, especially for stereotactic radiosurgery (SRS), knowing the exact volume and shape and the precise position of a lesion is very important. Sometimes X-ray projection images, such as angiograms, become the best choice for lesion identification. However, while the exact target position can be acquired by bi-projection images, 3D target reconstruction from bi-projection images is considered to be impossible. The aim of this study was to reconstruct the 3D target volume from multiple projection images. It was assumed that we knew the exact target position in advance, and all processes were performed in Target Coordinates, where the origin was the center of the target. We used six projections: two projections were used to make a Reconstruction Box and four projections were for image acquisition. The Reconstruction Box was made up of voxels of 3D matrices. Projection images were transformed into 3D in this virtual box using a geometric back-projection method. The resolution and the accuracy of the reconstructed target volume were dependent on the target size. An algorithm was applied to an ellipsoid model and a horseshoe-shaped model. Projection images were created geometrically using C program language, and reconstruction was also performed using C program language and Matlab ver. 6(The Mathwork Inc., USA). For the ellipsoid model, the reconstructed volume was slightly overestimated, but the target shape and position proved to be correct. For the horseshoe-shaped model, reconstructed volume was somewhat different from the original target model, but there was a considerable improvement in determining the target volume.

  • PDF

The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams (고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 1995
  • Lithium Fluoride (LiF; TLD-100) crystal chips are normally used as thermolu minescence dosimeters (abbreviated as NC-100) for estimating the absorbed dose to the skin of a patient or in a solid water phantom undergoing radiotherapy with megavoltage photon (6 and 15MV) beams. In general, investigation has revealed a reduction in the sensitivity of NC-100 chips after many runs through heating cycles. A TLD-100 chip laminated with gold plate (140${\mu}{\textrm}{m}$) on the upper surface layer of its face toward the photon beam (abbreviated as GC-100) has properties different from that of a NC-100 chip activated by incident photons and contaminant electrons with various lower energies coming from the gantry head and air. Activation of the valence band electrons of GC-100 chips by incident photons, positrons and electrons-which come from the gold plate by mainly pair production process and partly from Compton scattering-results in more enhanced signal intensity, higher response per monitor unit, as well as a good linearity with monitor units and independence of dose rate. Since the electron beams (6 and 15 MeV) do not have the probability of pair production process with gold plate, there is only a small difference (about a 3.3% increase for 15 MeV) in the signal gaps in the TL readout for electron beams between GC- and NC-100 chips. The 3.3% increase is entirely due to the buildup caused by the 140 m gold plate. The sensitivity of GC-100 chips is much more susceptible to high energy photon beams than electron one because of pair production. The interaction of high energy photon with a material of high atomic number, such as the good plate in this case, results in a considerably significant probability of pair production. The gold plate on the NC-100 chips acts as not only an intensifier of their signals but also acts as a filter of contaminant electrons in therapeutic high energy X-ray beams.

  • PDF

Factors Affecting to Bone Mineral Density in Postmenopausal Women (폐경기 여성의 골밀도에 영향을 주는 인자)

  • Jung, Seung-Pil;Lee, Keun-Mi;Lee, Suk-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.261-271
    • /
    • 1996
  • Introduction: Osteoporosis, the most common metabolic bone disorder, is a condition of reduced bone density and increased susceptibility to fractures. Osteoporosis is a major public health problem and a significant cause of morbidity in postmenopausal women. Therefore family physicians as primary care physicians are in a key position for preventing and treating this disorder. So we studied the factors affecting to bone mineral density in postmenopausal women. Materials and Methods: A total of 136 spontaneous postmenopausal women were participated in the study. They have measured spinal bone mineral density by dual energy x-ray absorptiometry from January 1992 to June 1995 at Yeungnam University Hospital. Age, height, weight, age at menarche and menopause, number of child and breast feeding child, history of oral pill ingestion, family history of osteoporosis, amount of milk and coffee ingestion, consumption of tobacco and alcohol and physical activity were assessed by qustionnaire and medical records. Results: The mean age is 55.2 and mean age at menopause is 47.9. Height, weight and physical activity were significantly positive correlated to bone mineral density. But age, duration after menopause and number of child were significantly negative correlated. Also age, height, weight, physical activity and duration after menopause were significantly correlated to % age-matched bone mineral density. In multiple regression analysis, which dependent variable is bone mineral density, duration after menopause, physical activity and weight were significant contributors. Duration after menopause is most the largest contributor. In multiple regression analysis, which dependent variable is % age-matched bone mineral density to adjust the age effect, physical activity and weight were significant contributors. Physical activity is most the largest contributor. Conclusions: Among factors affecting to BMD in postmenopausal women, physical activity and weight were more important factors. Therefore continuous physical activity is significant factor to prevent osteoporosis in postmenopausal women.

  • PDF

The Retrospective Analysis of 1,162 Traffic Accident Inpatients in Korean Medicine Hospital (교통사고로 한방병원에 입원한 환자 1,162명에 대한 후향적 분석)

  • Shin, Jae-Hwa;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.233-250
    • /
    • 2013
  • Objectives The purpose of this study was to investigate the characteristics of inpatients who were admitted to Korean medicine hospital due to traffic accident. Methods 1,162 traffic accident patients who were admitted to department of Korean Rehabilitation Medicine of Cheonan Korean Medicine Hospital, Dae-Jeon University from 1st, January, 2011 to 31th, December, 2012 were analyzed according to the medical charts. Results 1. The average treatment result was 3.22 and in most (71.52%) of the patients, symptoms were more than improved. 2. In distribution according to age and sex, people in their 30s numbered the most both in male (12.65%) and female (14.72%). The 1,162 inpatients comprised of 457 (39.33%) male and 705 (60.67%) female. 3. 541 (46.56%) patients admitted in 2011 and 621 (53.44%) patients admitted in 2012. 4. 695 (59.81%) patients visited Cheonan Korean Medicine Hospital within 0~2 days after their traffic accident, followed by 242 (20.83%) patients who visited within 3~5 days after their traffic accident. Patients who admitted earlier showed more improvement in symptoms. 5. The average admission days were 9.32 days. Most (57.66%) patients discharged within 1 week. 6. 825 (71.00%) patients were driving sedan at the time of accident, followed by 105 (9.04%) SUV owners and 71 (6.11%) pedestrians. 7. Rear-end collision accident numbered the most (45.61%), followed by lateral collision (24.35%) and frontal collision (14.72%). 8. Most frequently prescribed examination was X-ray (95.52%), followed by CT (8.69%) and MRI (3.01%). 9. Most frequently given diagnosis was sprain (1,126 (96.90%) patients), followed by concussion & abrasion (178 (15.32%) patients) and fracture (109 (9.38%) patients). 10. Most frequently given Korean medicine treatment was acupuncture (1,162 (100%) patients), followed by anti-inflammatory pharmacopuncture (652 (56.11%) patients) and moxibustion (462 (39.76%) patients). 11. Most frequently given Korean medicine physiotherapy was infra-red (1,161 (99.91%) patients), followed by cupping therapy (1,152 (99.14%) patients) and hotpack (1,137 (97.85%) patients). 12. Most frequently prescribed herb medicine was huishou-san (13.51%), followed by dangguixu-san (12.65%) and yaojiao-tang G (7.06%) Conclusions In this study, people in their 30s, females, within 0~2 days since the accident took the highest percentage from each category of patients who admitted to Korean Medicine Hospital due to traffic accident. Patients who admitted earlier showed more improvement in symptoms and also discharged earlier.

Clinical Characteristics of False-Positive Lymph Node on Chest CT or PET-CT Confirmed by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Lung Cancer

  • Lee, Jongmin;Kim, Young Kyoon;Seo, Ye Young;Choi, Eun Kyoung;Lee, Dong Soo;Kim, Yeon Sil;Hong, Sook Hee;Kang, Jin Hyoung;Lee, Kyo Young;Park, Jae Kil;Sung, Sook Whan;Kim, Hyun Bin;Park, Mi Sun;Yim, Hyeon Woo;Kim, Seung Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.339-346
    • /
    • 2018
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure to evaluate suspicious lymph node involvement of lung cancer because computed tomography (CT) and $^{18}F$-fluorodeoxyglucose positron emission tomography-CT (PET-CT) have limitations in their sensitivity and specificity. There are a number of benign causes of false positive lymph node such as anthracosis or anthracofibrosis, pneumoconiosis, old or active tuberculosis, interstitial lung disease, and other infectious conditions including pneumonia. The purpose of this study was to evaluate possible causes of false positive lymph node detected in chest CT or PET-CT. Methods: Two hundred forty-seven patients who were initially diagnosed with lung cancer between May 2009 and December 2012, and underwent EBUS-TBNA to confirm suspicious lymph node involvement by chest CT or PET-CT were analyzed for the study. Results: Of 247 cases, EBUS-TBNA confirmed malignancy in at least one lymph node in 189. The remaining 58 patients whose EBUS-TBNA results were negative were analyzed. Age ${\geq}65$, squamous cell carcinoma as the histologic type, and pneumoconiosis were related with false-positive lymph node involvement on imaging studies such as chest CT and PET-CT. Conclusion: These findings suggest that lung cancer staging should be done more carefully when a patient has clinically benign lymph node characteristics including older age, squamous cell carcinoma, and benign lung conditions.

Acupuncture, ST-36 Electroacupuncture and Moxa Treatment of Abdominal Pain due to Bowel Obstruction in Cancer Patients : Case Report (말기 암 환자의 장폐색성 복통에 대한 침구 및 족삼리 전침 치험 2례)

  • Kim, So Yeon;Choi, Jun Yong;Park, Seong Ha;Kwon, Jung Nam;Lee, In;Hong, Jin Woo;Han, Chang Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.2
    • /
    • pp.238-242
    • /
    • 2014
  • Here we described 2 cancer patients treated by acupuncture for abdominal pain as a complication of bowel obstruction. The patient 1, 43-year-old man was treated with surgery, radiotherapy and chemotherapy for rectal cancer. Two years after surgery, he complained of acute abdominal pain due to small bowel adhesion band. Bowel obstruction and symptoms were not improved by conservative therapy like as fasting, keeping Levin tube, and fluid therapy. 4 months later, he could eat a little rice water, but ileus and abdominal pain persisted despite of applying opiod drug and patch. Got started on acupuncture, electroacupuncture(ST-36) and moxa treatment, pain was relived gradually. He could stop opioids 1 month later and ileus was improved after acupuncture therapy for 2 months. The patient 2, 65-year-old woman got hepatectomy, cholecystectomy, and chemotherapy with cholangiocarcinoma. 6 months after surgery, she got laparotomy again for biopsy of new mass around ascending colon. She started eating after gas passing, but felt abdominal distension. Diffuse paralytic ileus was diagnosed by abdominal X-ray, and she got started conservative therapy. During ST-36 electroacupuncture therapy, symptoms like abdominal pain and distension were improved and could stop opiod patch. But eating aggravated ileus again and clinical finding of mechanical bowel obstruction was appeared. Based on these cases, acupuncture and moxa therapy could be helpful for improving abdominal pain and ileus, but possibility of malignant bowel obstruction should be considered especially in cancer patients.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

  • Cho, Jin Dong;Chun, Minsoo;Son, Jaeman;An, Hyun Joon;Yoon, Jeongmin;Choi, Chang Heon;Kim, Jung-in;Park, Jong Min;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.29 no.3
    • /
    • pp.92-100
    • /
    • 2018
  • The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth ($PDD_{10}$) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was $99.1%{\pm}1.0%$, and those for absolute dose distribution was $97.2%{\pm}2.7%$, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

Change of MTF for Sampling Interval in Digital Detector (디지털 검출기에서 샘플링 간격에 따른 MTF의 변화)

  • Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.225-230
    • /
    • 2014
  • Assessments of medical image was improved in accordance with development of medical imaging systems. One of them is edge method to determining MTF(Modulation Transfer Function) based on the Fujita method. Fujita was reduced sampling interval used slightly angulated slit to the direction of pixel array and composited finely sampled LSF to determine presampling MTF. In this study, we investigate the effect of sampling interval on the MTF under a digital imaging system by changing wire angle. The wire method was equivalent to the slit method except signal appearance. A Simens's MAMMOMAT Inspiration with $0.085{\times}0.085mm^2$ pixel size made by amorphous selenium was used and 96% accuracy on MTF in twice sampling interval compared with Fujita was obtained. However, three times of sampling interval showed 93% accuracy on 50% of MTF and 85% accuracy on 10% of MTF.