• Title/Summary/Keyword: Medical X-ray

Search Result 1,675, Processing Time 0.031 seconds

Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Correlation between the Portable X-ray and the Radiation Exposure dose in the Emergency Department: Cohort Study (응급실에서 이동식 단순 X-선 검사와 피폭선량과의 상관관계: 코호트 연구)

  • Kim, Yu Jung;Ahn, Hee Cheol;Sohn, You Dong;Ahn, Ji Yoon;Park, Seung Min;Lee, Won Woong;Lee, Young Hwan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: This study was conducted in order to determine the relationship between the number of portable X-rays and the radiation exposure dose for emergency medical service providers working in the emergency department (ED). Methods: A prospective study was conducted from February 15, 2013 to May 15, 2013 in the ED in an urban hospital. Six residents, seven emergency medical technicians (EMT), and 24 nurses were enrolled. They wore a personal radiation dosimeter on their upper chest while working in the ED, and they stayed away from the portable X-ray unit at a distance of at least 1.8 m when the X-ray beam was generated. Results: The total number of portable x-rays was 2089. The average total radiation exposure dose of emergency medical service providers was $0.504{\pm}0.037$ mSv, and it was highest in the EMT group, 0.85(0.58-1.08) mSv. The average of the total number of portable X-rays was highest in the doctor group, 728.5(657.25-809). The relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant(-0.186, p=0.269). Conclusion: Under the condition of staying away from the portable X-ray unit at a distance of least 1.8 m, the relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant.

  • PDF

Empirical Determination of a CT X-ray Spectra by Numerical Analysis using Transmission Data (투과선량의 수치해석에 의한 전산화단층영상장치 X선의 에너지 분포결정)

  • 최태진;김옥배;서수지
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1997
  • The knowledge of x-ray spectra is highly desirable in some investigation involves the differential penetrating power and absorption coefficient correction of various photon beam. The transmission data were obtained from the 80 kVp and 120 kVp of CT x-ray beam with the aluminium filter which is designed in a 30 cm of diameter and pipe-typed filter was prepared from 5.0 mm upto 92.3 mm of thickness. To obtain the reconstructed spectra of CT x-ray, the investigator used the iterative numerical analysis which has been extended to include the tungsten characteristics from experimental transmission data with energy interval of 2 keV. Comparison of the calculated transmission data from the reconstructed spectra with that of measurement shows good agreement in both 80 kVp and 120 kVp x-ray beams. This numerical analysis based on iteratively calculation of fractional exposure per energy interval shows the high potential of usefulness of determination the x-ray spectra from the attenuated beam in diagnostic energy range.

  • PDF

The Importance of Positioning in Left Lateral Chest X-Ray Examination (흉부 왼쪽 엑스선검사 시 위치 잡기의 중요성)

  • Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.287-294
    • /
    • 2023
  • This study was conducted to ultimately reduce unnecessary radiation exposure by emphasizing the need and importance of correct positioning by examining the positioning relationship of anatomical structures in the human body and changes in X-ray images according to changes in patient positioning during the left lateral chest X-ray examination. This study investigated and analyzed previously published papers and books on the left lateral chest X-ray examination to find out the importance of positioning in the left lateral chest X-ray examination. To find out the importance of correct positioning in the left lateral chest X-ray, we compared three images of incorrectly positioned right thorax and left thorax rotated forward and the lower median surface of the body leaning against the image receptor. In the left lateral chest examination, a distorted image was obtained in which the shape of the anatomical structure observed in the image was changed according to the presence or absence of rotation of the patient and the inclination of the median visual surface. X-ray images with the most accurate and large amount of information were obtained from X-ray images with the correct positioning performed during left lateral chest X-ray examination. Therefore, It is believed that the left lateral chest X-ray examination will have beneficial effects such as providing accurate medical information, preventing misdiagnosis, reducing social costs, and ultimately reducing radiation exposure.

Transport phenomena of a-Se:As thin film for digital X-ray Conversion Material (디지털 X-선 변환물질을 위한 비소(As) 첨가 비정질 셀레늄(a-Se) 박막의 수송현상)

  • Park, Chang-Hee;Kim, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.282-283
    • /
    • 2006
  • The transport phenomena of arsenic (As) doped amorphous selenium(a-Se:As) thin film for digital X-ray conversion material has been reported. The effect of As addition on the carrier mobility and recombination lifetime in a-Se:As sample has been measured using the moving photo-carrier grating (MPG) technique. An Increase in hole mobility and recombination was observed when 0.3% arsenic, was added into a-Se sample, whereas electron mobility decrease with arsenic addition due to the defect density. The fabricated a-Se:03% As device exhibited the highest X-ray sensitivity.

  • PDF

A Case Report on Simple Pelvic Fracture with Ostomy (단순 골반 골절된 장루술 환자 치험 1례)

  • An, Hunmo;Kim, Jun-Cheol;Na, Sam-Sik
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.13 no.1
    • /
    • pp.1-18
    • /
    • 2013
  • Objective : The objective of this study is to report the effectiveness of conservative treatment on simple pelvic fracture with ostomy. Methods : A female patient 65 years old with ostomy, who were diagnosed as simple pelvic fracture by X-ray, were treated with conservative treatment by herbal medication with acupuncture and physical therapy. We evaluated the effectiveness by checking X-ray, Digital Infrared Thermal Imaging(D.I.T.I.). Results : The symptoms of the patient got improved and X-ray showed the fracture were healing. Conclusions : Conservative korean medical treatment can be effectively used for a patient with simple pelvic fracture and ostomy.

A Thoracic Spine Segmentation Technique for Automatic Extraction of VHS and Cobb Angle from X-ray Images (X-ray 영상에서 VHS와 콥 각도 자동 추출을 위한 흉추 분할 기법)

  • Ye-Eun, Lee;Seung-Hwa, Han;Dong-Gyu, Lee;Ho-Joon, Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • In this paper, we propose an organ segmentation technique for the automatic extraction of medical diagnostic indicators from X-ray images. In order to calculate diagnostic indicators of heart disease and spinal disease such as VHS(vertebral heart scale) and Cobb angle, it is necessary to accurately segment the thoracic spine, carina, and heart in a chest X-ray image. A deep neural network model in which the high-resolution representation of the image for each layer and the structure converted into a low-resolution feature map are connected in parallel was adopted. This structure enables the relative position information in the image to be effectively reflected in the segmentation process. It is shown that learning performance can be improved by combining the OCR module, in which pixel information and object information are mutually interacted in a multi-step process, and the channel attention module, which allows each channel of the network to be reflected as different weight values. In addition, a method of augmenting learning data is presented in order to provide robust performance against changes in the position, shape, and size of the subject in the X-ray image. The effectiveness of the proposed theory was evaluated through an experiment using 145 human chest X-ray images and 118 animal X-ray images.