• 제목/요약/키워드: Medical Technology

검색결과 8,006건 처리시간 0.035초

Change of Dendritic Cell Subsets Involved in Protection Against Listeria monocytogenes Infection in Short-Term-Fasted Mice

  • Young-Jun Ju;Kyung-Min Lee;Girak Kim;Yoon-Chul Kye;Han Wool Kim;Hyuk Chu;Byung-Chul Park;Jae-Ho Cho;Pahn-Shick Chang;Seung Hyun Han;Cheol-Heui Yun
    • IMMUNE NETWORK
    • /
    • 제22권2호
    • /
    • pp.16.1-16.20
    • /
    • 2022
  • The gastrointestinal tract is the first organ directly affected by fasting. However, little is known about how fasting influences the intestinal immune system. Intestinal dendritic cells (DCs) capture antigens, migrate to secondary lymphoid organs, and provoke adaptive immune responses. We evaluated the changes of intestinal DCs in mice with short-term fasting and their effects on protective immunity against Listeria monocytogenes (LM). Fasting induced an increased number of CD103+CD11b- DCs in both small intestinal lamina propria (SILP) and mesenteric lymph nodes (mLN). The SILP CD103+CD11b- DCs showed proliferation and migration, coincident with increased levels of GM-CSF and C-C chemokine receptor type 7, respectively. At 24 h post-infection with LM, there was a significant reduction in the bacterial burden in the spleen, liver, and mLN of the short-term-fasted mice compared to those fed ad libitum. Also, short-term-fasted mice showed increased survival after LM infection compared with ad libitum-fed mice. It could be that significantly high TGF-β2 and Aldh1a2 expression in CD103+CD11b- DCs in mice infected with LM might affect to increase of Foxp3+ regulatory T cells. Changes of major subset of DCs from CD103+ to CD103- may induce the increase of IFN-γ-producing cells with forming Th1-biased environment. Therefore, the short-term fasting affects protection against LM infection by changing major subset of intestinal DCs from tolerogenic to Th1 immunogenic.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 김빛나;조석원;이주영;유광열;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.23-30
    • /
    • 2015
  • 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 기존 140 keV의 99mTc에 비해 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았으며 환자 주변의 외부선량 분포에 대한 영 향을 분석하여 방사선 종사자의 피폭 관리에 도움이 되고자 하였다. 10 명의 환자를 대상으로 하였으며 평균연령은 $47.7{\pm}6.6$ 세였다. 환자의 키는 평균 $165.5{\pm}3.8cm$, 몸 무게 평균은 $65.9{\pm}1.4kg$으로 비슷한 몸무게의 환자를 대상으로 하였다. 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치에서 측정하였고 측정 후에 즉시 이동형 방사선 차폐체을 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리에서 선량률을 측정하였다. 거리에 따른 선량률 변화와 차폐 전, 후의 투과율을 구하였다. 평균 10 cm 거리에서는 머리 부분이 $105.40{\mu}Sv/h$로 가장 높게 나타났으며 발 부분에서 $15.85{\mu}Sv/h$로 가장 낮게 나타났다. 200 cm 거리에서는 머리, 가슴, 복부 부분에서 비슷한 선량률이 나타났다. 머리 부분에 서 차폐 전 100 cm에서 $9.56{\mu}Sv/h$, 150 cm에서 $5.23{\mu}Sv/h$, 200 cm에서 $3.40{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, $1.27{\mu}Sv/h$로 측정되었다. 가슴 부분에 서 차폐 전 100 cm에서 $8.54{\mu}Sv/h$, 150 cm에서 $4.90{\mu}Sv/h$, 200 cm에서 $3.44{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, $1.13{\mu}Sv/h$로 측정되었다. 복부 부분에 서 차폐 전 100 cm에서 $9.83{\mu}Sv/h$, 150 cm에서 $5.15{\mu}Sv/h$, 200 cm에서 $3.18{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, $1.23{\mu}Sv/h$로 측정되었다. 투과율은 거리에 따라 증가함을 알 수 있었다. 거리가 멀어질수록 선량율이 낮아지는 것을 확인할 수 있었으며 차폐를 하였을 경우 차폐를 하지 않았을 때보다 1 / 4 정도 더 낮아지는 것을 확인할 수 있었다. 검사를 진행하는 근무자는 환자와의 거리를 멀리 할 수 없기 때문에 방사선 피폭이 증가할 수밖에 없다. 따라서 적절한 차폐를 한다면 방사선 종사자의 방사선 피폭을 줄 일 수 있을 것이다.

PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화 (The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters)

  • 신규설;동경래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.373-379
    • /
    • 2007
  • 목 적: PET이 PET-CT로 오면서 가장 큰 차이를 보이고 있는 점은 감쇄보정을 위한 투과영상의 차이이다. PET CT에서는 CT영상을 감쇄보정에 이용하고 있으며, CT 요인들이 PET 영상의 감쇄보정시 영향을 줄 수 있을 것으로 예상된다. 본 연구에서는 CT의 관전압과 관전류의 변화에 따라 PET의 정량성 평가로 이용되는 SUV(standard uptake value)의 값이 변화가 있는지를 평가하였다. 재료 및 방법: Data spectrum's lung phantom을 이용하여 $^{18}F$-FDG 1.909 mCi(팬텀 1)와 $913\;{\mu}Ci$(팬텀 2) 각각 물과 함께 넣고 흔들어 균일한 상태를 만든 후, 관전압을 80 kVp, 100 kVp, 120 kVp, 140 kVp까지, 관전압변화 당 관전류 10 mA에서 100 mA까지 각각 10 mA씩 변화를 주어 CT 영상을 얻었다. PET 영상을 각각의 CT영상을 이용하여 재구성 하였으며, 같은 부위에서의 SUV값을 구하여 그 차이를 비교하였다. 결 과: 팬텀 1의 SUV는 관전압 80, 100, 120, 140 kVp CT영상을 이용했을 때, 각각 $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$, $12.27{\pm}0.009$로 나타났다. 팬텀 2에서는 관접압을 달리 하였을 때 각각 $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$, $4.52{\pm}0.005$의 SUV를 보였다. 이들은 모두 관전압을 달리 하였을 때 통계적으로 유의한 SUV 변화를 보이지 않았다. 또한 관전류의 변화에서도 팬텀 1, 2 모두에서 유의한 SUV 차이는 나타나지 않았다. 결 론: 본 연구 결과 CT 요인의 변화가 PET 영상에서 SUV에 유의한 영향을 미치지 않았다. 따라서 PET CT 이용 시 SUV에 유의한 영향 없이 임상적 조건에 맞게 CT 요인들을 변화 시키는 응용이 가능할 것으로 생각된다.

  • PDF

부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 - (A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

병원 단위비용 결정요인에 관한 연구 (Analyses of the Efficiency in Hospital Management)

  • 노공균;이선
    • 한국병원경영학회지
    • /
    • 제9권1호
    • /
    • pp.66-94
    • /
    • 2004
  • The objective of this study is to examine how to maximize the efficiency of hospital management by minimizing the unit cost of hospital operation. For this purpose, this paper proposes to develop a model of the profit maximization based on the cost minimization dictum using the statistical tools of arriving at the maximum likelihood values. The preliminary survey data are collected from the annual statistics and their analyses published by Korea Health Industry Development Institute and Korean Hospital Association. The maximum likelihood value statistical analyses are conducted from the information on the cost (function) of each of 36 hospitals selected by the random stratified sampling method according to the size and location (urban or rural) of hospitals. We believe that, although the size of sample is relatively small, because of the sampling method used and the high response rate, the power of estimation of the results of the statistical analyses of the sample hospitals is acceptable. The conceptual framework of analyses is adopted from the various models of the determinants of hospital costs used by the previous studies. According to this framework, the study postulates that the unit cost of hospital operation is determined by the size, scope of service, technology (production function) as measured by capacity utilization, labor capital ratio and labor input-mix variables, and by exogeneous variables. The variables to represent the above cost determinants are selected by using the step-wise regression so that only the statistically significant variables may be utilized in analyzing how these variables impact on the hospital unit cost. The results of the analyses show that the models of hospital cost determinants adopted are well chosen. The various models analyzed have the (goodness of fit) overall determination (R2) which all turned out to be significant, regardless of the variables put in to represent the cost determinants. Specifically, the size and scope of service, no matter how it is measured, i. e., number of admissions per bed, number of ambulatory visits per bed, adjusted inpatient days and adjusted outpatients, have overall effects of reducing the hospital unit costs as measured by the cost per admission, per inpatient day, or office visit implying the existence of the economy of scale in the hospital operation. Thirdly, the technology used in operating a hospital has turned out to have its ramifications on the hospital unit cost similar to those postulated in the static theory of the firm. For example, the capacity utilization as represented by the inpatient days per employee tuned out to have statistically significant negative impacts on the unit cost of hospital operation, while payroll expenses per inpatient cost has a positive effect. The input-mix of hospital operation, as represented by the ratio of the number of doctor, nurse or medical staff per general employee, supports the known thesis that the specialized manpower costs more than the general employees. The labor/capital ratio as represented by the employees per 100 beds is shown to have a positive effect on the cost as expected. As for the exogeneous variable's impacts on the cost, when this variable is represented by the percent of urban 100 population at the location where the hospital is located, the regression analysis shows that the hospitals located in the urban area have a higher cost than those in the rural area. Finally, the case study of the sample hospitals offers a specific information to hospital administrators about how they share in terms of the cost they are incurring in comparison to other hospitals. For example, if his/her hospital is of small size and located in a city, he/she can compare the various costs of his/her hospital operation with those of other similar hospitals. Therefore, he/she may be able to find the reasons why the cost of his/her hospital operation has a higher or lower cost than other similar hospitals in what factors of the hospital cost determinants.

  • PDF

가교화 찹쌀전분의 물리화학적 성질 및 유과제조 특성 (Physicochemical Properties of Cross-linked Waxy Rice Starches and Its Application to Yukwa)

  • 유철;최현욱;김종태;안순철;최성원;김병용;백무열
    • 한국식품과학회지
    • /
    • 제39권5호
    • /
    • pp.534-540
    • /
    • 2007
  • 유과 제조 시 제조 시간을 단축할 수 있는 소재를 개발하기 위하여 찹쌀전분을 $POCl_3$와 반응시켜 가교화 찹쌀전분을 제조하고 이들의 물리화학적 특성을 연구하였다. 가교화 찹쌀전분의 치환율은 0.04-2.73으로 나타났으며, 팽윤력은 일반 찹쌀전분에 비해 약간 증가되는 경향을 보였으며 용해도는 일반 찹쌀전분보다 낮은 경향을 보였다. 등온흡습곡선은 가교화에 따른 유의적인 차이를 보이지 않았다. 전분의 pasting 특성을 검토한 결과, 호화개시온도는 가교화에 따른 변화가 없는 것으로 나타났으며, 최대점도, holding strength, final viscosity, setback은 일반 찹쌀전분보다 높아지는 결과를 나타냈다. 열적특성은 호화개시온도, 최대호화온도, 호화종결온도 그리고 호화엔탈피 모두 각 전분간에 유의적인 차이가 나타나지 않았다. X-ray회절 분석 결과로 볼 때, 가교화 찹쌀전분 및 일반 찹쌀전분 모두 A형의 결정 형태를 나타내었고, 상대적 결정화도의 차이가 나타나지 않는 것으로 보아 가교화가 찹쌀전분의 결정형영역에는 영향을 주지 않는 것으로 보여진다. 가교화 찹쌀전분을 사용하여 제조한 유과의 경우 일반 찹쌀을 장시간 침지한 후 제조한 시료와 비슷한 팽화율을 나타내었으며 시료의 변색 반응이 나타나지 않는 것으로 보아 유과 제조용 소재로서 적합한 것으로 판단되었다.

동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰 (A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy)

  • 함준철;반영각;박민수;조석원;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.96-101
    • /
    • 2012
  • 사구체 여과율은 신기능의 평가 및 신 질환의 조기 발견 및 만성 신 질환 환자의 경과 관찰에 중요한 지표가 된다. 본 연구에서는 동적 신장 신티그래피의 Gates법과 Modified Gates법을 채혈을 이용한 MDRD법 공식을 기준으로 그 차이를 비교, 분석하고자 한다. 2010년 11월부터 2011년 8월까지 본원에 내원하여 신장 신티그래피 검사를 시행한 45명의 환자를 대상으로 시행하였다. 이 중 20명의 환자는 AGUS(Philips Medical System, Cleveland, OH, USA) 장비의 Gates법과 MDRD법(Modification of Diet Renal Disease) 공식에 의한 사구체 여과율 값을 비교하였으며, 20명의 환자는 INFINIA (General Electric Healthcare, Wisconsin, MI, USA) 장비의 Modified Gates법과 MDRD법 공식에 의한 사구체 여과율 값을 비교하였다. 마지막으로 경과 관찰 시 MDRD법 공식에 의한 사구체 여과율 변화가 없는 환자 5명을 대상으로 Gates법과 Modified Gates법을 비교하였다. Gates법과 Modified Gates법 모두 MDRD법 공식에 의한 사구체 여과율 값과 높은 상관 관계를 보였으며($p$<0.01, r=0.903, r=0.867), Gates법의 대응 차 평균은 $2.05{\pm}2.54mL/min/1.73m^2$로 나타났고, Modified Gates법의 대응 차 평균은 $25.2{\pm}3.71mL/min/1.73m^2$로 나타났다. 마지막으로 5명의 환자에서 실시된 Gates법과 Modified Gates법의 비교는 높은 상관 관계를 보였으며($p$<0.05, r=0.949), 대응 차 평균은 $20.4{\pm}8.84mL/min/1.73m^2$ 로 나타났다. Gates법과 Modified Gates법 및 MDRD법 공식에 의한 사구체 여과율 값은 서로 높은 상관 관계를 보였다. 동적 신장 신티그래피 검사 시 사용되는 Gates법과 Modified Gates법의 상관 관계를 인지하고 검사를 진행 한다면, 진단능을 향상시켜 정확한 신기능의 평가가 이루어질 것으로 사료된다.

  • PDF

PET/CT 공동운영에 대한 사례 연구 (A Case Study about PET/CT Collaboration Operation)

  • 김창호;표성재
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.87-92
    • /
    • 2010
  • 2003년 당시 PET/CT를 구입하기로 결정하였다. 장비가 고가인 관계로 장비 회사가 공동 운영이라는 판매 제안을 하게 되었는데 본 병원은 공동 운영 방식을 선택하지 않았고 자체 구매 방식을 선택하였다. 본 연구는 그 당시 제안하였던 공동 운영 방식을 현실에 대입하여 사후 분석으로 공동운영의 사례를 보고자 한다. 먼저 2004년부터 2008년까지 5년 동안의 건수와 수가를 넣어(ABC 원가 계산) 수익 분석을 하였다. 그리고 2003년 제안하였던 공동 운영 방식을 동 기간 동안 건수와 수가를 넣어(ABC 원가 계산) 수익 분석을 하였고, 자체 구매 방식을 비교하여 그 차이를 알아보았다. 2004년도 첫해에 자체 구입 손익은 4억 9천 2백만 원의 적자였으며, 제안된 공동 운영 수지 분석 상으론 1억 1천 7백만 원의 적자로 나타났다. 2005년도는 자체 구입 손익은 1억 5백만 원의 적자였으며, 공동 운영은 8천 7백만 원의 적자로 나타났다. 2006년도는 수익이 역전되어 자체 구입 손익은 5억 1천 3백만 원의 흑자로 돌아섰으며, 공동 운영 수지 분석 상으론 9천 9백만 원의 적자가 이어졌다. 2007-8년도의 자체 구입과 공동 운영의 수익의 증가 폭은 더욱 벌어지고 있다. 2004년부터 2008년까지 자체구입의 소계는 10억 8천 8백만 원의 흑자였으며, 공동 운영의 소계는 6억 7천만 원의 적자로 분석되었다. 공동 운영의 수지 분석 결과는 병원의 자체 구입 수익보다 무려 16억 원의 차이로 나타났다. 이는 결국 초기 투자 비용을 아꼈다고 하지만 손익에서 알 수 있듯이 장비 가격을 반영하고도 큰 이익이 발생되어 공동 운영의 허실를 보여주는 반증이라 하겠다. 고가의 장비를 구입하여 수익을 창출하기 위해서는 상당히 많은 어려움이 있다. 위험 분산을 위한 경제적 분석, 초기 투자 비용의 적정성, 임상에서의 필요성, 진단적 가치 등 여러 가지를 고려한 후 장비를 구입해야 될 것이다.

  • PDF

$^{99m}Tc$ 발생기의 24시간 내 2회 용출의 유용성 평가 (The Evaluation of Usefulness of Two Times Elution a Day of $^{99m}Tc$ Using $^{99}Mo$-$^{99m}Tc$ Generator)

  • 김정호;서한경;정영환;김영수;김병철;권용주;이정옥;박영순;김동윤
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.83-86
    • /
    • 2010
  • $^{99}Mo$-$^{99m}Tc$ 발생기의 원료물질인 몰리브덴은 원자로에서 생산되고 있으나 현재 의료용 방사성 동위원소를 공급하는 두 원자로인 캐나다 온타리오주의 초크리버(Chalk River)와 네덜란드 페튼(Petten) 원자로의 노후화로 인한 유지 보수로 가동이 정지된 이후세계적인 몰리브덴 품귀 현상은 발생기 공급차질로 이어 지고있다. 이에 저자들은 발생기의 효율적인 운용 방법을 찾아 $^{99m}Tc$ 생산량을 증가 시키고 그 결과로 얻은$^{99m}Tc$의 안전성을 실험을 통해 확인하였다. 교정일자가 동일한 두 대의 발생기(Malinckrodt Medical, Dutch), 40.5 GBq (1500 mCi)를 이용하여 월요일부터 금요일까지 5일 동안 1회/일(24시간 주기, 오전8시 용출) 총 5회 용출한 $^{99m}Tc$의 방사능과, 5일 동안 2회/일(오전8시와 오후1시 용출) 총 10회 용출한 $^{99m}Tc$의 방사능을 비교 분석 하였다. 용출된 $^{99m}Tc$의 안정성을 $^{99}Mo$-$^{99m}Tc$ 발생기 정도 관리 항목 중 성상 검사, pH 검사, 발열성 물질 검사(LAL test), 무균 검사, 발생기의 화학 순도 검사, 방사화학적 순도 검사, 방사성 핵종의 순도 검사를 통해 확인해 보았다. 24시간 주기로 주 5회 용출한 $^{99m}Tc$의 총 방사능은 평균 168.2 GBq (4545 mCi)였고, 24시간 주기 용출 방법에 오후1시 추가 용출을 실시하여 주 10회 용출한 $^{99m}Tc$의 총 방사능은 평균 230.5 GBq (6230 mCi)로 24시간 주기의 주 5회 용출한 방사능보다 총 62.3 GBq (1685 mCi), 일 평균 12.46 GBq (337 mCi)로 전체 용출 방사능이 27.04% 증가 하였으며 각 시간 별로 얻어진 $^{99m}Tc$의 정도 관리는 정상 범위 내에 있었다. 이번 실험을 통하여 2회/일 용출방법이 1회/일 용출방법보다 62.3 GBq (1685 mCi)의 더 많은 방사능의 $^{99m}Tc$을 생산 할 수 있었으며 각 시간 별로 얻어진 $^{99m}Tc$의 정도 관리는 정상 범위 내에 있었다. 이에 따라 각 시간 별로 용출된 $^{99m}Tc$을 방사성 표지 화합물과 결합시켜 검사를 시행하여도 무관할 것으로 생각된다.

  • PDF