• 제목/요약/키워드: Medical Instruments

Search Result 532, Processing Time 0.026 seconds

Measurement of Qi Induced by the Needle Insertion on LI4, LI11 Accupoint using the Oriental Medicine Instruments (인체(人體)의 합곡(合谷) 곡지(曲池) 침자(鍼刺)에 관한 한방진단기기적(韓方診斷機器的) 접근(接近))

  • Jang, K.S.;Na, C.S.;So, C.H.
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.159-178
    • /
    • 1995
  • After acupuncture needles were inserted on apkok(LI4) and Kokchi(LI11) accupoints, physiological changes induced by the varitions of 'Qi' were measured. The body temperature and pulse frequency were fromed to be decreased observed and we presumed that the needle insertion induced some changes of Qi in meridian and this seemed to be achieved by a certain process of Qi induction. We applied EAV, nervinemeter and pulse-taking machine which is widely used as oriental medicine instruments, to the same vounteers and observed the significant variations for each apparatus in spite of partial lack of reproducibility. In this paper, we described about the physical quantity measured by the medical appartatus and how it was related to the variation of Qi The proper conditions used for good oriental medicine instruments have also been suggested.

  • PDF

Analysis of the Status of Infection Controls after Application of the Healthcare Accreditation System (의료기관 인증제 도입에 따른 감염관리 실태 분석)

  • Jeong, Sun-Young;Oh, Hyang-Soon;Chun, Hee-Kyung
    • The Korean Journal of Health Service Management
    • /
    • v.9 no.4
    • /
    • pp.33-49
    • /
    • 2015
  • Objectives : This study was conducted to measure the effects of healthcare accreditation (HA) on the changes in infection control (IC). Methods : Questionnaires were e-mailed to 60 hospitals from 23 October to 23 December, 2011. Data were analyzed by SPSS 12.0. Results : Finally 50 hospitals (83.0%) were enrolled in the study: Seoul area (40.0%), tertiary (76.0%), and >500 beds (98.0%). Nine hospitals (18.0%) had a full time infection control nurse[ICN] with 300 beds. Among various factors, ICN (36.0%), hospital facilities (66.0%), instruments (32.0%) and supplies (88.0%) all improved. Hand hygiene increased (53.1% vs 83.2%, p<.001), but it was continued only in 34.1% of hospitals. Healthcare-associated infection (68.4%), multi drug resistant organisms (42.1%) and outbreaks (26.3%) decreased. Reasons for difficulties in satisfying the HA standards were inadequate support which included hospital facilities, instruments, budget, and a shortage of ICNs and healthcare workers (HCWs). Conclusions : HA had effects on the IC, but they were transient. Staffing in ICN and HCW staffing, hospital facilities, instruments, and supplies all need to be improved.

Rating Scales for Attention-Deficit Hyperactivity Disorder in Adults (성인기 주의력결핍 과잉행동장애의 평가척도)

  • Kim, Ye-Ni;Jung, Hee-Yeon;Roh, Sung-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.21 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • This review aimed to assist clinicians in the identification and assessment of adult attention-deficit hyperactivity disorder (ADHD) with an emphasis on diagnostic and rating instruments. Pubmed and RISS were utilized to identify relevant studies and critical reviews on the diagnosis and assessment of adult ADHD, published between 1988 and 2010. The Adult ADHD Self-Report Scale-v1.1, the ADHD Rating Scale-IV, the Conners Adult ADHD Rating Scale, and the Current Symptoms Scale have been utilized for self-reporting of current ADHD symptoms. The Brown ADD Rating Scale, the ADHD Rating Scale-IV, the Current Symptoms Scale, and the Conners Adult ADHD Rating Scale have also been evaluated by an observer. The Childhood Symptom Scale and the Wender-Utah Rating Scale have been used for retrospective assessment of childhood ADHD symptoms and the Adult ADHD Investigator Symptom Rating Scale, the Adult Interview, the Brown ADD Diagnostic Form, the Conners adult ADHD diagnostic interview for DSM-IV, and the Wender-Reimherr Interview have been available as comprehensive diagnostic interviews. There is a wide variety of instruments available with respect to adult ADHD. The choice of appropriate instruments is essential for achieving accurate diagnosis and assessment of this disorder.

Analysis of Glottal Vibration (성대진동검사)

  • Wang, Soo-Geun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.1
    • /
    • pp.28-32
    • /
    • 2013
  • Because the human voice is produced through vibration of the vocal cords during the exhalation of airflow, it is important to observe the vibration pattern of the vocal cords in patients complaining of voice changes. However, it is not easy to observe the actual vibration pattern of the vocal cord because it vibrates so fast that it cannot be observed by the naked eye and it is located deep in the throat. Recently, with advances in instruments, including laryngoscopes and video camera systems, the vibration pattern of the vocal cords can now be observed. However, considering that present video camera systems can detect 30-60 images per second and the vocal cord vibrates at 100-200 and 200-300 times per second in men and women, respectively, it is not possible to record the whole mucosal wave of the vocal cord in real time. To overcome this limitation, a stroboscope, which converts fast movements of the vocal cord into slower images, has been developed. Since then, several instruments were developed to examine vocal vibration pattern. However, each instruments have advantages and disadvantages. Therefore, we should know about these things to apply them in patients with voice problem.

  • PDF

A Study of Magnetic Fluid Seals for Blood Sealing

  • Tomioka, Jun;Fukaishi, Akira;Ohba, Takashi
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.373-374
    • /
    • 2002
  • Magnetic fluid seals are used in a wide variety of gas and dust sealing applications. However, it is difficult to seal for liquid because of its characteristic. This study will be a basic guide for a magnetic fluid seal for liquid, especially for blood to be practically used in medical instruments such as rotary blood pumps by clarifying its seal properties. Sealing pressure test, durability test, and hemolysis test have been conducted for this seal. In this study, magnetic fluid, sealing fluid, eccentricity ratio, revolution speed were selected as parameters. As results of the tests, it has been found that the properties of magnetic fluid seal depend on the solvent and the saturation magnetization of magnetic fluid. Therefore, the selection of magnetic fluid is important for this seal. It also has been found that eccentricity ratio of the shaft caused harmful effect for seal properties. In conclusion, it has been showed that magnetic fluid seals could be possibly used in medical instruments such as blood pumps when blood come in contact with magnetic fluids.

  • PDF

The Study About The Correlation Between Assessment Instruments Of Knee OA and DITI (퇴행성 슬관절염 평가도구와 적외선 체열촬영과의 상관관계 연구)

  • Kim, Hyee-Kwon;Lee, Sang-Hoon;Seo, Jung-Chul;Lee, Seung-Deok;Choi, Sun-Mi;Kim, Yong-Seok
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.21-30
    • /
    • 2006
  • Objectives: The aim of this syudy is to validate the between Assessment Instruments of Knee OA and digital infrared thermographic imaging(DITI) and to find out the methods to assess knee OA by DITI. Methods: 60 subjects were evaluated. They were asked to answer VAS pain scale, WOMAC, KHAQ and LFI. Correlation was assessed by examining the spearman's rank correlation coefficients. Results: VAS, WOMAC and LFI was correlated with not only the thermal difference between Ant. knee and Post. knee, but also the lowest temperature of Ant. knee. Conclusion: DITI value was useful for evaluating the degree of OA. And we should find out that decrease of pain is correlated with change of DITI value.

  • PDF

Comparative Efficacy of Four Imaging Instruments for Breast Cancer Screening

  • Mehnati, Parinaz;Tirtash, Maede Jafari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6177-6186
    • /
    • 2015
  • Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results. Optical mammography had the highest sensitivity (p<0.001 and p<0.006) except with MRI. Digital mammography had the highest specificity for breast cancer imaging. A comparison of specificity between digital mammography and optical mammography was significant (p<0.021). If two or more breast diagnostic imaging tests are requested the overall sensitivity and specificity will increase. In this literature review study patients at high-risk of breast cancer were studied beside normal or sensitive women. The image modality performance of each breast test was compared for each.

Implementation of Medical Device Integration Module for Integrated Patient Monitoring System

  • Park, Myeong-Chul;Jung, Hyon-Chel;Choi, Duk-Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.79-86
    • /
    • 2017
  • In this paper, we implement a common module that can integrate multiple biometric information for integrated patient monitoring system. Conventional biomedical instruments have many devices attached to each patient, making it difficult to monitor abnormality signs of many patients in real time. In this paper, we propose a module for an integrated monitoring system that can perform centralized monitoring using a common module that integrates multiple measurement devices. A protocol for sending and receiving packets between the measuring device and the common module is designed, and the packets transmitted through the network are stored and managed through the integrated monitoring system and provide information to various users such as medical staff. The results of this study are expected to contribute to the management of patients and efficient medical services in hospitals.

Research on Current Execution of Customer Support Knowledge Management System of Medical Appliances Industry

  • Chung, Yi-Chan;Tsai, Chih-Hung;Tien, Shiaw-Wen;Lin, Lin-Yi
    • International Journal of Quality Innovation
    • /
    • v.8 no.3
    • /
    • pp.46-70
    • /
    • 2007
  • Customer Support Knowledge of Customer Support Organization is one of the important assets of enterprises and "Customer Support Knowledge Management" is also the critical aspect of Business Knowledge Management; however, the attributes of Customer Support Knowledge are complicated, diverse, renewed rapidly and difficult to be managed. Thus, in order to design a successful Customer Support Knowledge Management System, apart from the consideration of "human" and "information technology" aspects, the concerns of attributes and Customer Support Knowledge and industry characteristics should be involved for meeting the requirements of Customer Support Organization and allowing the organization to acquire the competitive advantage of "Differentiation Service". This research used the "Customer Support Knowledge Management System" in a high-tech industry as an example and treated the end users of medical instruments in different types of hospitals in Taiwan which have received the support service of our company in recent six months as the population. The end users were mostly the nursing executives or ultrasonic wave technical personnel in intensive care unit and they had similar educational background and incomes and adopted the medical instruments such as physical supervision system, ultrasonic wave system, heart start or ECG machine produced by our company; the research method was to randomly treat the investigation results of the telephone customers' satisfaction from respective 30 end users in the population three months before and after this system execution as the samples and use hypotheses to validate if the end users' customer satisfaction significantly improved in terms of "Remote Support," "On-site Support," "Service Turn Around time," "Technical Competence" and "Manner" in order to understand the influence and managerial significance of execution of "Customer Support Knowledge Management System" on Customer Support Organization.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.