• Title/Summary/Keyword: Medical Imaging Devices

Search Result 154, Processing Time 0.028 seconds

Extracting gall bladders from ultrasound images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Kato, Kiyoshi;Tsukuda, Masaaki;Matsuoka, Jun-nosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.248-251
    • /
    • 1995
  • Nowadays, the internal images of a human body can be easily provided by the ultrasound imaging, the X-ray CT, or the MRI device, among which the ultrasound imaging device has good resolution for soft tissues of a human body compared with the other devices. Furthermore, the use of ultrasound imaging devices will increase in future especially in the obstetrics, territory, since it does not give harm to the human body. Although several techniques have been investigated until now in order to extract organs from ultrasound images, very few of them have achieved satisfactory results because of low contrast and high noise nature of images. This paper proposes a technique for automatic extraction of the gall bladder area from ultrasound images. The proposed technique first extracts a small reliable area of a gall bladder from an ultrasound image employing smoothing, binarization, expanding and shrinking, and labeling, and then expands the area referring to the binarized version of the original image. The technique is examined its performance by real ultrasound images of a gall bladder and satisfactory results are obtained. Some problems to be solved are discussed finally.

  • PDF

A Study on MRI Semi-Automatically Selected Biomarkers for Predicting Risk of Rectal Cancer Surgery Based on Radiomics (라디오믹스 기반 직장암 수술 위험도 예측을 위한 MRI 반자동 선택 바이오마커 검증 연구)

  • Young Seo, Baik;Young Jae, Kim;Youngbae, Jeon;Tae-sik, Hwang;Jeong-Heum, Baek;Kwang Gi, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.11-18
    • /
    • 2023
  • Currently, studies to predict the risk of rectal cancer surgery select MRI image slices based on the clinical experience of surgeons. The purpose of this study is to semi-automatically select and classify 2D MRI image slides to predict the risk of rectal cancer surgery using biomarkers. The data used were retrospectively collected MRI imaging data of 50 patients who underwent laparoscopic surgery for rectal cancer at Gachon University Gil Medical Center. Expert-selected MRI image slices and non-selected slices were screened and radiomics was used to extract a total of 102 features. A total of 16 approaches were used, combining 4 classifiers and 4 feature selection methods. The combination of Random Forest and Ridge performed with a sensitivity of 0.83, a specificity of 0.88, an accuracy of 0.85, and an AUC of 0.89±0.09. Differences between expert-selected MRI image slices and non-selected slices were analyzed by extracting the top five significant features. Selected quantitative features help expedite decision making and improve efficiency in studies to predict risk of rectal cancer surgery.

A Design of Access Control Method for Security Enhance based Smart Device (스마트 디바이스 기반의 보안성 강화를 위한 접근제어 기법 설계)

  • Park, Jungoh
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.11-20
    • /
    • 2018
  • Smart devices refer to various devices and control equipment such as health care devices, imaging devices, motor devices and wearable devices that use wireless network communication (e.g., Wi-fi, Bluetooth, LTE). Commercial services using such devices are found in a wide range of fields, including home networks, health care and medical services, entertainment and toys. Studies on smart devices have also been actively undertaken by academia and industry alike, as the penetration rate of smartphones grew and the technological progress made with the fourth industrial revolution bring about great convenience for users. While services offered through smart devices come with convenience, there is also various security threats that can lead to financial loss or even a loss of life in the case of terrorist attacks. As attacks that are committed through smart devices tend to pick up where attacks based on wireless internet left off, more research is needed on related security topics. As such, this paper seeks to design an access control method for reinforced security for smart devices. After registering and authenticating the smart device from the user's smart phone and service provider, a safe communication protocol is designed. Then to secure the integrity and confidentiality of the communication data, a management process such as for device renewal or cancellation is designed. Safety and security of the existing systems against attacks are also evaluated. In doing so, an improved efficiency by approximately 44% compared to the encryption processing speed of the existing system was verified.

Auto-Positioning of Patient in X-ray Diagnostic Imaging (진단 엑스선 영상에서 환자 위치잡이의 자동화)

  • Yang, Won Seok;Son, Jung Min;Kwon, Su Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.793-799
    • /
    • 2018
  • As interest in artificial intelligence has increased, artificial intelligence has been actively studied in the medical field. In Korea, artificial intelligence has been applied to medical imaging devices such as X-ray imaging, Computer Tomography and Magnetic Resonance Imaging and artificial intelligence capable of acquiring radiation images of patients without radiologists in the future Medical devices are expected to be invented. This study was an initial study on the automation of patient positioning in X - ray imaging. We used x-ray equipment and human phantoms to evaluate the positioning. The program used Visual Studio 2010 MFC and the image was in the size $1450{\times}1814$. The pixel values were converted to contrasts with values of 0 to 255 that can be visually recognized and output to the monitor. We developed a procedure algorithm program that predicts the angle of the output image through three pixel coordinate values and induces the patient to perform correct positioning according to the voice guidance according to the angle. In the next study, we will study the artificial intelligence to grasp the structure itself and calculate the angle, rather than conveying the reference of coordinates to artificial intelligence. In the future, it is expected that it will be helpful in the study of artificial intelligence from shooting to positioning through the automation of positioning.

A New Medical Lead for Various MRI Systems (다양한 MRI 시스템에서 사용가능한 의료용 리드선)

  • Kim, Hongjoon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.429-432
    • /
    • 2015
  • Radio Frequency (RF) coils in Magnetic Resonance Imaging (MRI) systems interact with a patient's tissues, resulting in the absorption of RF energy by the tissues. The presence of an electrically conducting medical implant may concentrate the RF energy and causes tissue heating near the implant devices. Here we present a novel design for a medical lead to reduce this undesired heating. Specific Absorption Rate (SAR), an indicator of heating, was calculated. Remcom XFdtd software was used to calculate the peak SAR distribution (1g and 10 g) in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T MRI), 128 MHz (3 T MRI) and 300 MHz (7 T MRI) using a model of an MR birdcage body coil. Our results demonstrate that, our proposed design of adding nails to the medical lead can significantly reduce the SAR for different MRI systems.

Wireless PACS

  • Kim, Hyeon-Cheol
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.130-136
    • /
    • 2002
  • One of current trends of medical technology is analog to digital. Moreover, The Government put a premium on PACS(Picture Archiving and Communication System) for Medical Insurance in November, 1999. Therefore many hospitals are installing(or planning to install) PACS facilities on their buildings. However most of hospitals didn't consider PACS facilities in the beginning of construction. In particular, the Networking is one of the most difficult things for PACS installation. There is no space for network equipments, and no path for network lines, etc. To solve these problems, wireless network is proposed. The wireless network is divided to three parts mainly. One is the wireless communication for Local Area Network, another is the data transmission through a satellite for Tele-Radiology, and the last one is the technology using Bluetooth for each sub-system of PACS. But there are other problems in wireless systems, i.e., network bandwidth, system stability, interference with other devices. The purpose of this paper is to suggest the future and new trend of PACS including all the problems.

  • PDF

Transport property of a Se:As films for digital x ray imaging

  • Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.85-88
    • /
    • 2006
  • The transport properties of amorphous selenium typical of the material used in direct conversion x-ray imaging devices are reported. The effects of As addition on the carrier mobility and recombination lifetime in amorphous selenium (a-Se) films have been studied using the moving photocarrier grating (MPG) technique. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with the drift mobilities of holes and electrons obtained by time of flight (TOF) measurement.

  • PDF

Anomaly-based Alzheimer's disease detection using entropy-based probability Positron Emission Tomography images

  • Husnu Baris Baydargil;Jangsik Park;Ibrahim Furkan Ince
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.513-525
    • /
    • 2024
  • Deep neural networks trained on labeled medical data face major challenges owing to the economic costs of data acquisition through expensive medical imaging devices, expert labor for data annotation, and large datasets to achieve optimal model performance. The heterogeneity of diseases, such as Alzheimer's disease, further complicates deep learning because the test cases may substantially differ from the training data, possibly increasing the rate of false positives. We propose a reconstruction-based self-supervised anomaly detection model to overcome these challenges. It has a dual-subnetwork encoder that enhances feature encoding augmented by skip connections to the decoder for improving the gradient flow. The novel encoder captures local and global features to improve image reconstruction. In addition, we introduce an entropy-based image conversion method. Extensive evaluations show that the proposed model outperforms benchmark models in anomaly detection and classification using an encoder. The supervised and unsupervised models show improved performances when trained with data preprocessed using the proposed image conversion method.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis

  • Hadilou, Mahdi;Gholami, Leila;Ghojazadeh, Morteza;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.141-153
    • /
    • 2022
  • Purpose: This study aimed to identify the prevalence and extension of the anterior loop (AL) of the mental nerve in different populations and according to different cone-beam computed tomography (CBCT) imaging settings. Materials and Methods: Medline/PubMed, Embase, Scopus, Web of Science, and ProQuest were searched. The main inclusion criterion was ALs evaluated in CBCT images. The quality of studies was assessed with the Joanna Briggs Institute risk of bias checklist. Subgroup analyses were conducted for sex, side, continent, voxel size, field of view, and type of CBCT-reconstruction images with a random-effects model. Results: Sixty-three studies with 13,743 participants (27,075 hemimandibles) were included. An AL was found in 40.6% (95% CI: 32.8%-48.9%, P<0.05) of participants and 36.0% (95% CI: 27.5%-45.5%, P<0.05) of hemimandibles, in 34.9% (95% CI: 25.1%-46.2%, P<0.05) of males and 34.5% (95% CI: 23.5%-47.4%, P<0.05) of females. The average length of ALs was 2.39 mm (95% CI: 2.07-2.70 mm, P<0.05). Their extension was 2.13 mm (95% CI: 1.54-2.73 mm, P<0.05) in males and 1.85 mm (95% CI: 1.35-2.36 mm, P<0.05) in females. Significant differences were observed regarding the prevalence and length of ALs among continents and for its measured length on different CBCT-reconstruction images, but not between other subgroups. Conclusion: AL was a relatively common finding. The voxel size and fields of view of CBCT devices were adequate for assessing AL; however, a 2-mm safety margin from anatomical structures(such as the AL) could be recommended to be considered when using CBCT imaging.