• Title/Summary/Keyword: Medical Imaging

Search Result 4,198, Processing Time 0.031 seconds

A Comparison on the Characteristics of Cerebrovascular Disease Patients Admitted to Some Western and Oriental Hospitals (일부 양·한방 병원에 입원한 뇌혈관질환 환자의 특성 비교)

  • Yu, Dae-Jin;Ryu, So-Yeon;Park, Jong;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.1
    • /
    • pp.65-79
    • /
    • 2001
  • Cerebrovascular disease(CVD) is one of the major causes of death in Korea as well as most countries in the world and the disease gives great burden to humans socio-economically due to its high fatality and common occurrence of disability as the sequelae. This study was performed to investigate the utilization of western hospital(WH) or oriental hospital(OH) due to CVD and compare the type and the clinical characteristics of patients with CVD between WH and OH located in Kwangju City, Chonnam Province and Chonbuk Province. We reviewed the medical records of 1,070 patients who were discharged from 12 WIT and 6 OH from January to March, 2000 and confirmed for the diagnosis of CVD. Fifty-one percent of the subjects were treated at WH and forty-nine percent at OH. Females were more prevalent than males. As well, the most common age group among these subjects was found to be 70 years and older. About 92% in W~H and 80% in OH received brain imaging diagnostic procedures such as CT or MRI. The cerebral infarction was the most common type of CVD when compared by the kind of utilized hospitals, sex, age group except patient Group who was treated at WH and whose age was lower than 50 years old. The cerebral hemorrhage was more frequent than cerebral infarction among this group. The proportion of cerebral hemorrhage was decreasing and that of cerebral infarction was increasing with age. The most common clinical manifestations of undetermined type of CVD was paralysis of lower extremity in WIT and paralysis of upper extremity in OH. In cerebral hemorrhage loss of consciousness in WIT and dysarthria in OH were most frequently manifested, while in the case of cerebral infarction hemiplegia in WIT and dysarthria in OH were the most common complaints. The interval from the onset of disease to admission to the hospital was 5.5 days in WH arid 31.4 days in OH and the difference was statistically significant. Average admission duration of patients at OH was longer than WH, but it was not statistically significant. In conclusion these results suggest that the effort for systematic and efficient management of CVD patients was necessary for close co-operation and role arrangement between WH and OH considering the positive and negative points of western and oriental medicines.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Clinical Presentations and Causative Organisms in Children and Adolescents with Osteoarticular Infections: A Retrospective Study (소아청소년기에 발생한 골관절염의 임상 양상 및 원인균에 대한 고찰)

  • Lee, Soyoung;Kim, Han Wool;Cho, Hye-Kyung;Yun, Yoe Hon;Ryu, Kyung Ha;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.3
    • /
    • pp.154-163
    • /
    • 2015
  • Purpose: Osteoarticular infections in children and adolescents are important because it can cause functional compromise if appropriate treatment is delayed. Therefore, this study was designed to describe the clinical presentations and causative organisms of osteoarticular infections in children and adolescents in order to propose early diagnosis method and an appropriate empiric antimicrobial therapy. Methods: Forty-two medical records were reviewed retrospectively, which were confirmed as osteomyelitis (OM) or septic arthritis (SA) at Department of Pediatrics or Orthopedic Surgery in patients under 18 years old of Ewha Womans University Mokdong Hospital from March 2008 to March 2015. Results: We identified 21 cases of OM, 13 cases of SA and 8 cases of OM with SA. There were 31 males and 11 females and mean age was 7.1 years old. The most common symptoms were pain and tenderness of involved site. Major involved bones were femur (10 cases, 34.5%), tibia (7 cases, 24.1%) and major involved joints were hip (9 cases, 42.9%), and knee (5 cases, 23.8%). Increased serum C-reactive protein and erythrocyte sedimentation rate were observed in 37 cases (88.1%) respectively. Magnetic resonance imaging was performed in 40 cases among 42 cases and was used to demonstrate osteoarticular infections and other adjacent infections. Nine cases (23.7%) among 38 cases and 20 cases (50.0%) among 40 cases were positive in blood culture and infected site culture respectively. The most common causative organism was Staphylococcus aureus, which was represented in 22 cases (75.9%), of which nine cases (40.9%) were resistant to methicillin. Conclusions: S. aureus was the most common causative organism of osteoarticular infections in children and adolescents and the proportion of MRSA was high in this study. Therefore, we recommend vancomycin as the first empiric antimicrobial therapy and suggest that further study is necessary to elucidate an appropriate guideline for treatment which takes into account MRSA proportion.

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

Possibility of Combined Meningitis in Under 90-Day-Old Infants With Urinary Tract Infection (생후 90일 미만 영아의 요로 감염에서 세균성 수막염의 동반 가능성)

  • Hwang, Jun Ho;Kim, Su Yeong;Lee, Na Mi;Yi, Dae Yong;Yun, Sin Weon;Chae, Soo Ahn;Lim, In Seok;Park, Ji Young
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.2
    • /
    • pp.84-95
    • /
    • 2022
  • Purpose: Urinary tract infections (UTIs) are the most common serious bacterial infections in young infants. Lumbar puncture (LP) has been used to diagnose coexisting meningitis in infants under 90 days of age with suspected UTI in many hospitals. However, the incidence of bacterial meningitis associated with UTIs is low. We aimed to describe the prevalence of concomitant bacterial meningitis in young infants with UTIs. Methods: The medical records of infants with the first episode of UTI admitted to the Chung-Ang University Hospital from January 2010 to December 2019 were retrospectively reviewed. Infants aged < 90 days who underwent LP with initial evaluation were included. Demographic and clinical features, laboratory findings, and imaging findings were collected and analyzed. Results: Eighty-six infants with UTIs were enrolled in the study. The median age was 61.5 days (interquartile range, 42.3-73.8 days) and boys (90.7%) were predominant. Escherichia coli was the most common pathogen (n=80, 93.0%) and followed by Klebsiella species (n=5, 5.8%). Fifteen (18.1%) specimens produced extended spectrum β-lactamase (ESBL). Five (5.8%) infants had positive blood culture results. Seven (8.1%) infants showed pleocytosis in the cerebrospinal fluid, but none had coexisting bacterial meningitis. Twenty-four (30.8%) infants showed renal dilatation or hydronephrosis on ultrasonography. Dimercaptosuccinic acid (DMSA) scans revealed cortical defects in 17 (21.3%) infants while voiding cystourethrography revealed vesicoureteral reflux in 6 (46.2%) infants. Conclusion: Co-existing bacterial meningitis was not observed in young infants with UTIs. LP could not be routinely performed considering the clinical condition of <90 days old UTI patients.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF