• Title/Summary/Keyword: Medical Error

Search Result 1,090, Processing Time 0.03 seconds

Blind Signal Processing for Medical Sensing Systems with Optical-Fiber Signal Transmission

  • Kim, Namyong;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • In many medical image devices, dc noise often prevents normal diagnosis. In wireless capsule endoscopy systems, multipath fading through indoor wireless links induces inter-symbol interference (ISI) and indoor electric devices generate impulsive noise in the received signal. Moreover, dc noise, ISI, and impulsive noise are also found in optical fiber communication that can be used in remote medical diagnosis. In this paper, a blind signal processing method based on the biased probability density functions of constant modulus error that is robust to those problems that can cause error propagation in decision feedback (DF) methods is presented. Based on this property of robustness to error propagation, a DF version of the method is proposed. In the simulation for the impulse response of optical fiber channels having slowly varying dc noise and impulsive noise, the proposed DF method yields a performance enhancement of approximately 10 dB in mean squared error over its linear counterpart.

Assessing Misdiagnosis of Relapse in Patients with Gastric Cancer in Iran Cancer Institute Based on a Hidden Markov Multi-state Model

  • Zare, Ali;Mahmoodi, Mahmood;Mohammad, Kazem;Zeraati, Hojjat;Hosseini, Mostafa;Naieni, Kourosh Holakouie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.9
    • /
    • pp.4109-4115
    • /
    • 2014
  • Background: Accurate assessment of disease progression requires proper understanding of natural disease process which is often hidden and unobservable. For this purpose, disease status should be clearly detected. But in most diseases it is not possible to detect such status. This study, therefore, aims to present a model which both investigates the unobservable disease process and considers the error probability in diagnosis of disease states. Materials and Methods: Data from 330 patients with gastric cancer undergoing surgery at the Iran Cancer Institute from 1995 to 1999 were analyzed. Moreover, to estimate and assess the effect of demographic, diagnostic and clinical factors as well as medical and post-surgical variables on transition rates and the probability of misdiagnosis of relapse, a hidden Markov multi-state model was employed. Results: Classification errors of patients in alive state without a relapse ($e_{21}$) and with a relapse ($e_{12}$) were 0.22 (95% CI: 0.04-0.63) and 0.02 (95% CI: 0.00-0.09), respectively. Only variables of age and number of renewed treatments affected misdiagnosis of relapse. In addition, patient age and distant metastasis were among factors affecting the occurrence of relapse (state1${\rightarrow}$state2) while the number of renewed treatments and the type and extent of surgery had a significant effect on death hazard without relapse (state2${\rightarrow}$state3)and death hazard with relapse (state2${\rightarrow}$state3). Conclusions: A hidden Markov multi-state model provides the possibility of estimating classification error between different states of disease. Moreover, based on this model, factors affecting the probability of this error can be identified and researchers can be helped with understanding the mechanisms of classification error.

Human Errors and Human Factors in Service Delivery Processes: A Literature Review and Future Works (서비스 분야에서 인간공학과 인적오류 연구)

  • Hong, Seung-Kweon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.169-177
    • /
    • 2011
  • The aim of this study is to review previous studies on human errors in the service delivery processes. Service industry is sharply growing in the advanced countries. Many people are looking for something to contribute to the service industry. Although there are many research topics related to service domain that human factors and ergonomics specialists can do contribute, a few researchers are studying such topics. This paper indicated how previous researches on human factors and human errors have addressed the service domain, in order to prompt human factor study on the service domain. A variety of sources were inspected for literature reviews, including books and journals of managements, medicine, psychology, consumer behavior as well as human factor and ergonomics. The characteristics of human errors in the service domain were investigated. Human error studies in several service sectors were summarized such as medical service, automotive service operation, travel agent service and call center service. Until now, human factors community was not much interested in human errors in service domain. However, there is much space to contribute to service domain; human error identification, human error analysis and control of human error. The research of human error in service domain can provide clues to improve service quality. This paper helps to guide to identify human error of service domain and to design service systems.

Human Error Analysis in a Permit to Work System: A Case Study in a Chemical Plant

  • Jahangiri, Mehdi;Hoboubi, Naser;Rostamabadi, Akbar;Keshavarzi, Sareh;Hosseini, Ali Akbar
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • Background: A permit to work (PTW) is a formal written system to control certain types of work which are identified as potentially hazardous. However, human error in PTW processes can lead to an accident. Methods: This cross-sectional, descriptive study was conducted to estimate the probability of human errors in PTWprocesses in a chemical plant in Iran. In the first stage, through interviewing the personnel and studying the procedure in the plant, the PTW process was analyzed using the hierarchical task analysis technique. In doing so, PTWwas considered as a goal and detailed tasks to achieve the goal were analyzed. In the next step, the standardized plant analysis risk-human (SPAR-H) reliability analysis method was applied for estimation of human error probability. Results: The mean probability of human error in the PTW system was estimated to be 0.11. The highest probability of human error in the PTW process was related to flammable gas testing (50.7%). Conclusion: The SPAR-H method applied in this study could analyze and quantify the potential human errors and extract the required measures for reducing the error probabilities in PTW system. Some suggestions to reduce the likelihood of errors, especially in the field of modifying the performance shaping factors and dependencies among tasks are provided.

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

Estimation of RTP Accuracy Based the International Reference Level (국제기준을 적응한 치료계획시스템 정확성 평가)

  • Oh, Young-Kee;Kim, Ki-Hwan;Jeong, Dong-Hyeok;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • In this study, we have estimated error of calculation results for 5-type RTP systems and investigated a toleration for error of the RTPs referenced from the evaluation items of AAPM Report-62. For this study, we have introduced the concept of 'normal dose rate(NDR)' and compared the results of experiment and calculation from RTPs at the same reference level. The results from all RTPs were satisfied at various field shapes and heterogeneous phantom materials except the surface irregularity.

  • PDF

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Physicians' perception of and attitudes towards patient safety culture and medical error reporting (환자안전 문화와 의료과오 보고에 대한 의사의 인식과 태도)

  • Kang, Min-Ah;Kim, Jeong-Eun;An, Kyung-Eh;Kim, Yoon;Kim, Suk-Wha
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.110-135
    • /
    • 2005
  • The objectives of this study were (1) to describe doctors' perception and attitudes toward patient safety culture and medical error reporting in their working unit and hospitals, (2) to examine whether these perception and attitudes differ by doctors' characteristics, such as sex, position, and specialties, and (3) to understand the relationship between overall perception of patient safety in their working unit and each sub domain of patient safety culture. A survey was conducted with 135 doctors working in a university hospital in Korea. After descriptive analyses and chi-square tests of subgroup differences, a multivariate-regression of overall perception of patient safety in their unit with sub-domains of patient safety culture was conducted. Overall, a significant proportion of doctors expressed negative perception of their working units' patient safety culture, many reporting potentials for patient safety problems to occur in their unit. They also negatively viewed their hospital leadership's commitment on patient safety. Regarding the patient safety in their working unit, doctors were most worried about staffing level and observance of safety procedures. Most doctors did not know how and which medical error to report. They also perceived that medical errors would work against them personally and penalize them. About 22 percent of respondents believed that even seriously harmful medical errors were not reported.

Overview on Inborn Error of Metabolism involving Hepatic System (간기능 이상을 초래하는 유전성 대사질환)

  • Yoo, Han-Wook
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2013
  • Inborn error of metabolism usually presents with a constellation of clinical pictures involving multiorgan systems. Because of its rarity and clinical diversity, it is difficult to make diagnosis accurately and efficiently. Many inborn error of metabolism shows predominantly hepatic symptoms and signs. The onset of symptoms is also varying depending the disease. The onset might be even prenatal, either neonatal or infantile, and late childhood. The major manifestation patterns are jaundice or cholestasis, hepatomegaly with or without splenomegaly, hypoglycemia and acute or chronic hepatocellular dysfunction. Based on pronounced hepatic symptoms and onset of symptoms, differential diagnosis can be more easily made with subsequent further laboratory investigation. In this review paper, major inborn error of metabolism with hepatic symptoms are described from the perspective of mode of clinical presentations.

  • PDF

Medication Errors in Chemotherapy Preparation and Administration: a Survey Conducted among Oncology Nurses in Turkey

  • Ulas, Arife;Silay, Kamile;Akinci, Sema;Dede, Didem Sener;Akinci, Muhammed Bulent;Sendur, Mehmet Ali Nahit;Cubukcu, Erdem;Coskun, Hasan Senol;Degirmenci, Mustafa;Utkan, Gungor;Ozdemir, Nuriye;Isikdogan, Abdurrahman;Buyukcelik, Abdullah;Inanc, Mevlude;Bilici, Ahmet;Odabasi, Hatice;Cihan, Sener;Avci, Nilufer;Yalcin, Bulent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1699-1705
    • /
    • 2015
  • Background: Medication errors in oncology may cause severe clinical problems due to low therapeutic indices and high toxicity of chemotherapeutic agents. We aimed to investigate unintentional medication errors and underlying factors during chemotherapy preparation and administration based on a systematic survey conducted to reflect oncology nurses experience. Materials and Methods: This study was conducted in 18 adult chemotherapy units with volunteer participation of 206 nurses. A survey developed by primary investigators and medication errors (MAEs) defined preventable errors during prescription of medication, ordering, preparation or administration. The survey consisted of 4 parts: demographic features of nurses; workload of chemotherapy units; errors and their estimated monthly number during chemotherapy preparation and administration; and evaluation of the possible factors responsible from ME. The survey was conducted by face to face interview and data analyses were performed with descriptive statistics. Chi-square or Fisher exact tests were used for a comparative analysis of categorical data. Results: Some 83.4% of the 210 nurses reported one or more than one error during chemotherapy preparation and administration. Prescribing or ordering wrong doses by physicians (65.7%) and noncompliance with administration sequences during chemotherapy administration (50.5%) were the most common errors. The most common estimated average monthly error was not following the administration sequence of the chemotherapeutic agents (4.1 times/month, range 1-20). The most important underlying reasons for medication errors were heavy workload (49.7%) and insufficient number of staff (36.5%). Conclusions: Our findings suggest that the probability of medication error is very high during chemotherapy preparation and administration, the most common involving prescribing and ordering errors. Further studies must address the strategies to minimize medication error in chemotherapy receiving patients, determine sufficient protective measures and establishing multistep control mechanisms.