• Title/Summary/Keyword: Medical Device Management

검색결과 288건 처리시간 0.021초

콜라겐제제 봉합제 사용으로 인한 우측 대퇴동맥, 우측 슬와동맥 혈전증의 수술적 치료 (Surgical Treatment of Femoral & Popliteal Arteries Thrombosis Caused by Collagen Material Closure Device - A case report -)

  • 조태준
    • Journal of Chest Surgery
    • /
    • 제38권5호
    • /
    • pp.396-399
    • /
    • 2005
  • Manual or mechanical compression followed by 4 to 8 hours of bed rest is still the standard technique for accessing site management of the femoral arterial puncture site. But these methods are often uncomfortable and delay hospital discharge. Recently, a number of new devices to achieve hemostasis have been developed. These devices uses collagen to facilitate local hemostasis. But many complications associated with the use these devices have been reported internationally. We present a case of successful treatment of Rt. femoral and Rt. popliteal arteries thrombosis caused by Angioseal.

호흡동조 방사선치료에 사용되고 있는 RPM (Real-time Position Management) Respiratory Gating System의 호흡변화에 따른 정확성에 대한 고찰 (Consideration of the Accuracy by Variation of Respiration in Real-time Position Management Respiratory Gating System)

  • 나준영;강태영;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 2013
  • 목 적: 본원에서 시행하고 있는 호흡동조 방사선치료(Respiratory Gated Radiation Therapy, RGRT)는 RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)을 이용하여 실시하고 있다. 본 연구는 호흡변화에 따른 방사선치료의 정확성을 분석하고 평가하고자 한다. 대상 및 방법: 움직임을 임의로 조정할 수 있는 구동 팬텀(Motion Phantom)인 QUASAR Programmable Respiratory Motion Phantom (Moudus Medical Device Inc. CANADA)을 이용하였다. 폐암과 간암 환자 50명의 호흡을 분석하여 호흡의 변화를 관찰한 결과를 기준으로 주기 3초, 진폭 1.5 cm인 총 60초간의 기준호흡에서 매번 기저호흡(Baseline)을 기울기를 갖고 점진적으로 내려가는 경우와, 간헐적으로 기준 기저호흡 보다 더 내려가는 경우의 호흡 모양을 만들어 본원에서 사용되고 있는 Phase gating, 보통 30~70% gating 치료 방법과 동일하게 방사선을 조사하였다. 결 과: 점진적으로 매번 기저호흡이 0.01 cm, 0.03 cm, 0.05 cm씩 내려가는 호흡의 경우 모든 조건에서 방사선이 조사되었다. 간헐적으로 기저호흡이 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm 내려가는 경우도 모든 조건에서 방사선이 조사되어 RPM Respiratory Gating System에서 Phase gating 방식은 기저호흡 변화에 대하여 방사선이 모두 조사되었다. 결 론: 최적의 방사선치료를 위해 종양의 움직임을 고려하여 시행하는 호흡동조 방사선치료에서 RPM Respiratory Gating System의 Phase gating 방식은 본 연구에서와 같이 기저호흡의 변화가 호흡동조에 정확히 반영되지 않음을 알 수 있었다. 이에 호흡동조 방사선치료에는 무엇보다 환자의 호흡 관찰이 중요하다고 사료되며 호흡의 변화가 관찰되었다면 즉시 방사선치료를 멈추고 호흡을 관찰한 후 변화된 호흡상태에서 투시를 시행하여 치료부위를 다시 확인한 후에 치료를 재개하여야 한다고 사료된다.

  • PDF

초보자에서 후두튜브기도기와 후두마스크기도기의 삽관 비교 - 마네킨 연구 - (Comparison between laryngeal tube suction II and laryngeal mask airway in novice users - A manikin study -)

  • 황지영;조근자
    • 한국응급구조학회지
    • /
    • 제16권3호
    • /
    • pp.19-28
    • /
    • 2012
  • Purpose : The present study was designed to provide basic data for advanced pre-hospital airway management by comparing the insertion time and success rate between laryngeal tube suction II (LTS II) and laryngeal mask airway (LMA) in a manikin. Methods : A total of 32 participants were novice users to both of devices among paramedic students. After taking the introductory lecture and demonstrations, the participants made an attempt to insert the LTS II and LMA to compare the insertion time and success rate. They marked the easiness of insertion of the score ranged from 1 to 10 score scale and preference of the two devices. Results : The insertion time of the LTS II was significantly shorter than that of the LMA (p =.000). There was no significant difference between LTS II and LMA in the success rate. In the easiness of insertion, the score of LTS II $(8.47{\pm}1.41score)$ was significantly higher than that of LMA $(7.19{\pm}1.98score)$(p =.001). The preference of LTS II (75%) was much higher than that of LMA (25%). Conclusion : The manikin study data showed that the LTS II may be a good alternative airway device for providing and maintaining a patent airway.

U-Healthcare 환경에서 환자정보보호를 위한 전자차트 부분 암호화 기법 설계 (A Design of Electronic Health Records Partial Encryption Method for Protecting Patient's Information on the U-Healthcare Environment)

  • 신선희;김현철;박찬길;전문석
    • 디지털산업정보학회논문지
    • /
    • 제6권3호
    • /
    • pp.91-101
    • /
    • 2010
  • By using the U-Healthcare environment, it is possible to receive the health care services anywhere anytime. However, since the user's personal information can be easily exposed in the U-Healthcare environment, it is necessary to strengthen the security system. This thesis proposes the technique which can be used to protect the personal medical records at hospital safely, in order to avoid the exposure of the user's personal information which can occur due to the frequent usage of the electronic chart according to the computerization process of medical records. In the proposed system, the following two strategies are used: i) In order to reduce the amount of the system load, it is necessary to apply the partial encryption process for electronic charts. ii) Regarding the user's authentication process for each patient, the authentication number for each electronic chart, which is in the encrypted form, is transmitted through the patient's mobile device by the National Health Insurance Corporation, when the patient register his or her application at hospital. Regarding the modern health care services, it is important to protect the user's personal information. The proposed technique will be an important method of protecting the user's information.

국내 운반형인공호흡기 안전성 확보를 위한 분류체계 및 평가기준 제안 (A Proposal for a Classification System and Evaluation Standards for Ensuring the Safety of Transport Ventilator in Korea)

  • 김지현;조성구
    • 보건의료산업학회지
    • /
    • 제11권4호
    • /
    • pp.189-202
    • /
    • 2017
  • Objectives : This study aims to present a new classification system using evaluation standards to ensure the safety of transport ventilators used in Korea. Due to the rapid advancement of technology, various types of ventilators have been developed and as the range of application increases, so does demand. With quick access to information and a growing economy, the technology used in Korean hospitals is equivalent to that of other countries; however, regulatory and safety consciousness are still lagging in Korea. Methods : Based on researching overseas cases, reference data and standards for improving the current system in Korea are proposed. Results : According to the review of transport ventilator use in Korea, it was found that concerns about safety is due to the absence of a standardized classification system for evaluating the safety and effectiveness of transport ventilators. Conclusions : In order to improve the safety of patients and the quality of medical care, it is essential to establish guidelines and assessment standards guaranteeing the safety of transport ventilators in Korea. Clear definitions and classifications for devices must precede the application of such standards. In addition, effective evaluation standards should be developed in order to resolve problems and improve upon the current system through continuous validation.

한 종합병원의 MRI 채산성 사례 연구 (A Case Study on the MRI Profitability of a General Hospital)

  • 강창렬;송성호;임경태
    • 보건의료산업학회지
    • /
    • 제4권1호
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

고혈압 환자를 위한 블루투스 기반의 포터블 헬스케어 게이트웨이 개발 (Bluetooth based Portable Healthcare Gateway Development for Hypertention Patients)

  • 김종탁;소재영;김종훈;강운구
    • 디지털융복합연구
    • /
    • 제11권12호
    • /
    • pp.339-344
    • /
    • 2013
  • 최근 만성질환자의 증가로 생활 속에서 건강관리의 중요성이 증대되고 있다. 일상생활 중에 사용자에 의해서 측정된 생체신호가 특정 건강관리 디바이스에 의해서 자동으로 건강관리센터의 서버에 전송된다면 환자의 건강증대 및 건강관리 서비스의 확산에 기여할 것으로 예상된다. 본 논문에서는 사용자가 휴대 가능한 포터블 헬스케어 게이트웨이(Portable Healthcare Gateway)를 개발한다. 본 게이트웨이는 USB형으로 설계되고 표준화된 데이터 전송이 가능하여 사용자의 위치 및 PHD(Personal Health Device)에 제약을 받지 않고 데이터 전송이 가능하다. 개발된 포터블 헬스케어 게이트웨이는 유비쿼터스 환경에서 고객의 건강을 증진시킬 수 있는 효과적인 서비스를 제공한다.

진단용 엑스선 장치의 안전관리 검사에 관한 연구 (A Study on Safety Management Inspection of Diagnostic X-ray System)

  • 이후민;김현주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.887-893
    • /
    • 2018
  • 본 연구는 병원 및 대학교 등에 설치된 X선 발생장치를 대상으로 진단용 방사선 발생장치의 품질관리 항목을 적용하여 성능 비교를 하여 주기적인 성능관리의 중요성을 인식시켜 성능유지 및 관리에 도움을 주고자 한다. 우선 재현성 및 직선성 실험결과 모든 실험조건에서 합격기준에 부합되었으며 주기적인 정도관리가 부족한 GX-650장치의 경우 재현성 평가의 백분율 오차가 높았으며 직선성 평가에서는 관전압을 100 kVp로 설정 시 0.105로 백분율 오차에서 벗어나게 측정되었다. 또한 관전압 및 관전류의 정확도 평가결과 상대적으로 X선 발생횟수가 낮은 장치에서 백분율 오차가 낮은 것을 알 수 있었다. 반가층 실험은 모든 장치에서 관전압 별 반가층 기준에 모두 포함되었다. 따라서 병원용, 실습용 구분보다는 모든 장치의 정도관리의 중요성을 인식하고 적극적으로 장치의 성능관리를 시행하여 장치를 유지 관리해야 할 것이며 특수의료장비처럼 짧은 주기의 정도관리 제도를 마련해야 할 것으로 사료된다.

상태정보에 따른 체내삽입형 장치를 부착한 유-헬스케어 환자의 프라이버시 보호 프로토콜 (U-Healthcare user's privacy protection protocol with Implantable medical Device of State Information)

  • 정윤수;이상호
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.297-306
    • /
    • 2012
  • 최근 유헬스케어 시스템은 IT 기술과 의료서비스가 접목되면서 사용 범위가 점점 넓어지고 있다. 그러나 유헬스케어 시스템 중 체내삽입형 장치를 사용하는 환자의 경우, 환자의 프라이버시 예방과 안전한 접근 제어에 대한 대비책이 마련되어 있지 않아 그에 따른 프라이버시 보호 문제가 대두되고 있다. 본 논문에서는 체내삽입형 장치를 사용한 환자의 프라이버시를 보장하기 위해서 환자 정보를 가상화한 후 환자의 상태값과 수행값을 동기화함으로써 제3자의 불법적 접근을 예방할 수 있는 환자 프라이버시 보호 프로토콜을 제안한다. 제안된 프라이버시 보호 프로토콜은 사전에 관리 서버에 등록된 병원(의사, 간호사, 약국 등)의 권한정보에 따라 체내삽입형 장치를 부착한 환자의 개인정보의 열람범위를 제한하여 병원관계자의 불법적 업무 수행을 예방한다. 특히, 체내삽입형 장치와 게이트웨이 역할을 하는 가상장치는 접근 허가가 승인된 환자 정보 이외에 허가받지 않은 정보에 대해서 제 3자가 쉽게 접근하지 못하도록 환자의 상태값과 수행값을 동기화함으로써 환자의 프라이버시 관리의 효율성을 향상시키고 있다.

침도 침술시 부작용과 예방법에 관한 연구 (Clinical Characteristics of Poor Responders to Acupotomy and Safety Pretreatment Management)

  • 김성철
    • Journal of Acupuncture Research
    • /
    • 제25권4호
    • /
    • pp.117-125
    • /
    • 2008
  • Objectives : Analyze according to types of event causing the adverse outcome due to acupotomy, and discuss problems and safety reqirements to using this therapy in Korea. Methods : Based upon the indication, contraindication, treatment procedures, clinical obsevations, acupotomy-related adverse outcome case reports, the factors of damaging event were classified. Results : The main factors of adverse outcome by acupotomy were anatomical ignorance, contamination of device or hospital staff, failure to notice preexisting disease(cardiovascular disease, hypertension, renal failure, hemophilia, chronic Liver Disease, etc.), unskilled treatment procedures(massive bleeding) and techniques(nerve injury, hepatic and splenic injury, Pneumothorax). Conclusions : It is mandatory to prepare adequate sterilie aseptic technique. The clinician should ensure understand genernal health state of patient and anatomical direction.

  • PDF