• Title/Summary/Keyword: Medical Device Industry

Search Result 164, Processing Time 0.02 seconds

The Realization on GAS Sensor Module for Inteligent Wireless Communication (지능형 무선통신용 가스 센서 모듈 구현)

  • Kim, Hyo-Chan;Weon, Young-Su;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.123-132
    • /
    • 2012
  • Gas sensors has been used very differently that depending on following purposes; Automotive (exhaust gas, fuel mixture gas, oxygen, particulates), agriculture / food industry (fresh, stored, CO2, humidity, NH3, nitrogen oxide gas, organic gas, toxic gas emitted from pesticides and insecticides), industrial / medical (chemical gas, hydrogen, oxygen and toxic gases), military (chemical weapon), environmental measurements (CO and other air pollution consisting of sulfur and nitrogen gas), residential (LNG, LPG, butane, indoor air, humidity). The types of industrial toxic substances are known about 700 species and many of these exist in gaseous form under normal conditions. he multi-gas detection sensors will be developed for casualties that detect the most important and find easy three kinds of gases in marine plant; carbon dioxide(CO2), carbon(CO), ammonia(NH3). Package block consists of gas sensing device minor ingredient, rf front end, zigbee chip. Develope interworking technology between the sensor and zigbee chip inside a package. Conduct a performance test through test jig about prototype zigbee sensor module with rf output power and unwanted emission test. This research task available early address when poisonous gas leaked from large industrial site and contribution for workers' safety at the enclosed space.

Integrative medicine rehabilitation of simultaneous intra-dermal acupuncture (IDA) and neurodevelopmental treatment (NDT) for children with cerebral palsy: Pilot Study of Functional Near-Infrared Spectroscopy (뇌성마비 소아에 대한 중추신경계재활치료 및 피내침 병용치료에 관한 연구 - 기능성 적외선 분광법(fNIRS)를 이용한 예비 연구 -)

  • Chang, Seok Joo;Nam, Yeon Gyo;Kim, Ji Hyun;Ko, Mun Jung;Kwon, Bum Sun;Lim, Chi-Yeon;Min, Sang Yeon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.139-147
    • /
    • 2021
  • Objectives The purpose of this study is to investigate differences in brain activities when Neurodevelopmental treatment (NDT) is used alone compare to NDT is combined with intradermal acupuncture (IDA) treatment, using functional infrared spectroscopy (fNIRS) Methods Three children less than 7 year-old with cerebral palsy were participated. On their first visit, only NDT was used. After a week, they were treated with both NDT and IDA. During the treatment, fNIRS was used to measure any changes in their brain activities. Results In first patient with NDT, oxyhemoglobin level was increased during Standing exercise and Gait training compared to resting state. When the patient was treated with NDT and IDA, oxyhemoglobin level was decreased during Standing exercise and Gait training compared to resting state, and the result was significant (p<0.05). In second patient, oxyhemoglobin level was decreased in Gait training compared to resting state when NDT was used, but the level was increased when NDT and IDA were used in Gait training compared to resting state (p<0.05). In third patient, the difference in oxyhemoglobin levels between Gait training and resting state was significant (p<0.05). Conclusions Treatment involving both NDT and IDA has more potential to improve brain activities compared to that of NDT alone, and no adverse effect was reported. In order to confirm the finding, larger scale randomized controlled trials are needed.

Evaluation of Albumin Creatinine Ratio as an Early Urinary Biomarker for Chronic Kidney Disease in Dogs

  • Hyun-Min Kang;Heyong-Seok Kim;Min-Hee Kang;Jong-Won Kim;Dong-Jae Kang;Woong-Bin Ro;Doo-Won Song;Ga-Won Lee;Hee-Myung Park;Hwi-Yool Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.399-407
    • /
    • 2023
  • Chronic kidney disease (CKD) occurs in more than 15% of the dogs over 10 years of age and causes irreversible renal function deterioration. Therefore, it is important to diagnose CKD early and treat the disease properly. The purpose of this study aimed to to evaluate the clinical utility of urine albumin/creatinine ratio (ACR) using POC (point-of-care) device as an early detection urinary biomarker in CKD dogs and to confirm the correlation between ACR and other known CKD biomarkers. Urine and serum samples were obtained from 50 healthy dogs and 50 dogs with CKD. Serum blood urea nitrogen (BUN), creatinine, and symmetric dimethylarginine (SDMA) concentrations, and urine protein creatinine ratio (UPC) were measured. Urine specific gravity (USG) was evaluated using refractometer, and ACR was measured using an i-SENS A1Care analyzer. The ACR values of dogs with CKD were significantly different from those of healthy dogs (p < 0.001), as with other renal biomarkers. ACR showed significant differences between healthy dogs and dogs with CKD at every IRIS stage (p < 0.005), whereas no significant differences were observed between dogs with CKD IRIS stage I and healthy dogs with UPC. There are significant positive correlation between ACR and BUN (r = 0.611, p < 0.001), creatinine (r = 0.788, p < 0.001), SDMA (r = 0.747, p < 0.001), and UPC (r = 0.784, p < 0.001), and significant negative correlation between ACR and USG (r = -0.700, p < 0.001). In receiver operator characteristic curve analysis, the area under the curve (AUC) was 0.982 (95% CI 0.963-1.000, p < 0.001), with an optimal cut-off value of 64.20 mg/g (94% sensitivity and 94% specificity). Thus, ACR is a useful urinary biomarker for the early diagnosis of proteinuria in CKD and combined use of ACR and other renal biomarkers may be helpful for early diagnosis and prevention of CKD in dogs.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF