• 제목/요약/키워드: Median power

검색결과 192건 처리시간 0.022초

등장성 수축운동시 표피근전도의 주파수파라미터와 근지구력시간과의 상관성 (Relationship between Endurance Times and Frequency Parameters in Surface EMG during Isotonic Contraction Exercises)

  • 이상식;고재욱;장지훈;박원엽;이기영
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권3호
    • /
    • pp.135-140
    • /
    • 2012
  • Previous investigators have shown that the frequency compression is related to the muscle fatigue and the decreasing conduction velocity of muscle fibers. The aim of the present study was to investigate the relationship between endurance times and frequency parameters such as mean power frequency and median frequency in the surface EMG signal during isotonic contractions. Eight healthy subjects performed voluntary isotonic contractions of biceps Brachii muscle until their endurance times which were determined when the subject could no longer follow the contraction cycle. The regressive slopes of mean power frequency and median frequency were used to describe the frequency compression of the surface EMG signal, and to test the predictability of endurance time. As results of experiment, significant correlations were found between endurance time and the regressive slopes of mean power frequency and mean frequency computed over 50%Tend of endurance time.

Median Frequency Analysis of Shoulder Muscles Using EMG Power Spectrum Analysis After Rotator Cuff Repair

  • Kang, Jeong-Il;Moon, Young-Jun
    • International Journal of Contents
    • /
    • 제10권3호
    • /
    • pp.90-95
    • /
    • 2014
  • The purpose of this study was to analyze the changes in muscle fatigue by using electromyography (EMG) measurements of the median frequency of shoulder muscles of patients who underwent rotator cuff repair, and to provide basic data for efficient exercise methods during rehabilitation after the repair. In the study, 24 male and 8 female patients who underwent rotator cuff repair performed continuous passive shoulder joint motion for 3 weeks and the median frequency of their shoulder muscles before and after the repair were compared using measurements by EMG. The infraspinatus, supraspinatus, and serratus anterior muscles showed significant differences in the changes in the median frequency before and after the repair. Significant differences were also found in the median frequency of the three muscles both before and after the repair. Additionally, the middle deltoid muscle had a lower median frequency than the supraspinatus muscle before the repair and the infraspinatus muscle had a lower median frequency than the middle deltoid muscle after the repair. It is expected that these results will serve as important data in developing rehabilitation exercise programs for the infraspinatus, supraspinatus, and serratus anterior muscles by compensating the middle deltoid muscle with the lowest muscle fatigue after the rotator cuff repair erase.

롤러 슈즈 착용 후 보행시 근피로 상태에서 하지근의 근전도 Power Spectrum 분석 (EMG Power Spectrum Analysis of Wearing Roller Shoes on Muscle Fatigue in the Lower Extremity during Walking)

  • 김연정;윤창진;채원식;이민형;김헌수;정미라
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.239-245
    • /
    • 2007
  • The purpose of this study was to compare the electromyography signal's power spectrum mean and median tendencies appearing in the lower extremity during walking while wearing roller shoes. 9 male subjects volunteered who have no experience riding inline-skate or roller-skate, and have no record of musculoskeletal disorder. Subjects walked on treadmill twice for an hour (Once a week, one trial with the roller on and the other without roller, Walking velocity = 1.39 m/s). Electromyography was measured every 15 minute (0, 15, 30, 45, 60 minutes). Surface electrode sticked muscle at rectus femoris(R.F.), vastus lateralis(V.L.), vastus medialis(V.M.), biceps femoris(B.F.), tibialis anterior(T.A.), gastrocnemius lateralis(G.L.), gastrocnemius medialis(G.M.). At Rectus femoris, Vastus Lateralis, Vastus medialis, and Biceps femoris showed no statistically significant decrease of median frequency or mean edge frequency as time passes. Also, between two treatments (wearing the roller shoes vs not wearing the roller shoes), no statistically significant difference. After 60 minutes, mean edge frequency showed statistically significant decrease at tibalis anterior and after 45 minutes, mean edge frequency showed statistically significant decrease compared to wearing roller shoes without the wheels at gastrocnemius lateralis. At gastrocnemius medialis after 30 minutes, median frequency showed statistically significant decrease, and showed statistically significant difference compared to the control group. Wearing the roller shoes with wheels for a long time resulted in statistically significant decrease of mean edge frequency and median frequency in lower extremity, especially in shank muscles. Increase of wearing time of roller shoes and walking on a bumpy road wearing roller shoes with wheels result fatigue and thus, danger of injury.

Electromyographic analysis according to shoe weight during ambulation

  • Lee, Eunsang;Lee, Byunghoon;Cho, Juchul;Lee, Yongwoo;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • 제4권2호
    • /
    • pp.115-120
    • /
    • 2015
  • Objective: To examine the effects of different shoe weights on lower leg muscle fatigue when walking by electromyographic (EMG) analysis due to the most effective weight for loading not being established. Design: Cross-sectional study. Methods: Thirty healthy university students (15 male, 15 female) were enrolled and randomly assigned into three conditions, which included wearing athletic shoes with an addition of 300 g, 500 g, and 1,000 g weights respectively. Prior to walking, all subjects were instructed to sit in a chair for 10 minutes. All subjects walked at a speed of 3.6 m/s on a treadmill for 20 minutes without rest. EMG measurements were taken using the median power frequency to assess for the effect of the different weight of shoes on muscle fatigue of the soleus, gastrocnemius, and tibialis anterior while walking on a treadmill in an upright posture. EMG measurements were taken during the first and last 30 seconds of walking. Results: In terms of muscle fatigue, for the soleus, the median power frequency was significantly lower with 1,000 g compared with 300 g and 500 g (p<0.05). For the tibialis anterior, the median power frequency was significantly lower with 1,000 g than 300 g and 500 g (p<0.05). For the gastrocnemius, the median power frequency was significantly lower with 1,000 g compared with 300 g (p<0.05). Conclusions: Increased shoe weight increases soleus, gastrocnemius, and tibialis anterior muscle fatigue during ambulation.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

충청남도 내 산업단지 주변에 거주하는 주민들의 요중 비소 농도 (Urinary Arsenic Concentrations among Residents in the Vicinity of a Chungcheongnam-do Province Industrial Complex Area)

  • 김희찬;노상철
    • 한국환경보건학회지
    • /
    • 제42권3호
    • /
    • pp.224-233
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the relationship between residential surroundings, such as a power plant, steel mill and petrochemical facilities, and urinary arsenic concentrations in Chungcheongnam-do Province, Korea. Methods: Stratified by fish consumption and residential district, median and maximum block sampling was applied. A total of 346 spot urine samples were speciated for $As^{5+}$, $As^{3+}$, monomethylarsonic acid(MMA), dimethylarsonic acid (DMA) and arsenobetaine (AsB). Exposure assessment was based on questionnaires including data on sex, age, current tobacco use, fish consumption, type of water consumed, and occupational category. Results: Urinary $As^{5+}+As^{3+}+MMA+DMA$ concentrations of people living in the vicinity of a power plant ($GM=50.39{\mu}g/g$) were 61% higher than those of people living in the inland area according to median block sampling. Urinary $As^{5+}+As^{3+}+MMA+DMA+AsB$ concentrations of people living in the vicinity of industrial complex area were higher than those of people living in the inland area according to block sampling by median and maximum. Conclusion: Urinary arsenic concentrations of people living in vulnerable areas such as around industrial complexes, especially power plants, were higher than those of people living in an inland area.

음향방출을 이용한 유리의 비커스 압입 균열 특성 (Characteristics of Cracks under Vickers Indentation in Glass Using Acoustic Emission)

  • 박혜연;이종규;박흥일;이병우
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.72-77
    • /
    • 2012
  • Acoustic emission (AE) is known to be sensitive to fracture process and so it was expected that AE data may propose as a means of monitoring the fracture information. The aim of this study is to analyze the characteristic of AE signal emitted from glass during Vickers indentation. To observe AE characteristics by surface effect, both glass and coating glass were studied. During Vickers indentation loading, AE signal resulted from penny-like crack is detected. During Vickers indentation unloading, AE signal resulted from both radial/median crack and lateral crack is detected. In case of indentation on glass, the emission energy(${\epsilon}$) is found to be approximately proportional to the fourth power of the crack length. In case of indentation on coating glass, the emission energy(${\epsilon}$) is approximately proportional to the crack length.

Analysis of the Likelihood of Internal Radiation Exposure When Decommissioning a Nuclear Power Plant in Korea

  • Jiung Kim;Tae Young Kong;Seongjun Kim;Jinho Son;Changju Song;Jaeok Park;Seungho Jo;Hee Geun Kim
    • 방사선산업학회지
    • /
    • 제18권2호
    • /
    • pp.141-145
    • /
    • 2024
  • In Publication No. 66 of the International Commission on Radiological Protection, an activity median aerodynamic diameter (AMAD) of 5 ㎛ is considered in internal exposure dose assessment owing to inhalation of radionuclides in a workplace. However, analysis of aerosols generated during dismantling experiments, such as in the oxy-cutting of a reactor vessel conducted in Korea, revealed that the radioactive aerosols have AMAD ranging from 0.024 to 0.064 ㎛. Such extremely fine aerosols can induce internal exposure if inhaled. In particular, alpha radionuclides in aerosols can lead to significantly higher levels of radiation exposure than beta and gamma radionuclides, thus highlighting the need to establish appropriate internal exposure radiation protection programs and monitoring systems that specifically address alpha radionuclides when decommissioning nuclear power plants in Korea.

동적 GPS 간섭신호 제거에 효율적인 주파수 영역에서의 K-median 필터를 이용한 문턱치 설정 기법 (The Spectral Domain K-median Threshold Filtering Method for the Dynamic GPS Interference Excision)

  • 김준오;이상정
    • 한국항행학회논문지
    • /
    • 제21권3호
    • /
    • pp.243-250
    • /
    • 2017
  • GPS 신호체계는 대역확산 방식을 사용하며, 신호의 크기는 시스템 잡음수준 이하이므로 외부 전파 간섭신호에 매우 취약하며, 이는 GPS를 이용하는 선박 또는 항공기 에 대한 안전 운항을 제한 할 수 있다. 본 논문은 이러한 GPS 간섭 신호 제거를 위한 K-median 방식의 문턱치 설정 방식을 적용한 주파수 영역의 신호 처리 기법을 제안하며, 이는 기존에 보편적으로 사용되는 시간 영역에서의 간섭신호 제거 방식보다, 시간에 따른 신호 변화가 큰 간섭신호를 인가한 조건에 대해서 상대적으로 우수한 성능을 가짐을 확인하였다.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.