• Title/Summary/Keyword: Medial loop

Search Result 9, Processing Time 0.026 seconds

Medial Loop of V2 Segment of Vertebral Artery Causing Compression of Proximal Cervical Root

  • Park, Sung Bae;Yang, Hee-Jin;Lee, Sang Hyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.513-516
    • /
    • 2012
  • Objective : It is rare that the medial loop in the V2 segment of the vertebral artery (VA) causes compression of the proximal cervical root of the spinal cord without leading to bony erosion and an enlarged foramen. We evaluated the clinical significance and incidence of the medial loop in the V2 segment of the VA. Methods : We reviewed the records from 1000 consecutive patients who had undergone magnetic resonance imaging evaluation of the cervical spine between January 2005 and January 2008. The inclusion criteria were that over a third of the axial aspect of the VA located in the intervertebral foramen was inside the line between the most ventral points of the bilateral lateral mass, and that the ipsilateral proximal root deviated dorsally because of the medial loop of the VA. We excluded cases of bone erosion, a widened foramen at the medial loop of the VA, any bony abnormalities, tumors displacing VA, or vertebral fractures. The medical records were reviewed retrospectively to search for factors of clinical significance. Results : In six patients (0.6%), the VA formed a medial loop that caused compression of the proximal cervical root. One of these patients had the cervical radiculopathy that developed after minor trauma but the others did not present with cervical radiculopathy related to the medial loop of the VA. Conclusion : The medial loop of the VA might have a direct effect on cervical radiculopathy. Therefore, this feature should be of critical consideration in preoperative planning and during surgery.

$Co_2$ Corrosion Mechanism of Carbon Steel in the Presence of Acetate and Acetic Acid

  • Liu, D.;Fu, C.Y.;Chen, Z.Y.;Guo, X.P.
    • Corrosion Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.227-232
    • /
    • 2007
  • The corrosion behavior of carbon steel (N80) in carbon dioxide saturated 1%NaCl solution with and without acetic acid or acetate was investigated by weight-loss test, electrochemical methods (polarization curve, Electrochemical impedance spectroscopy). The major objective is to make clear that the effect of acetic acid and acetate on the corrosion of carbon steel in $Co_2$ environments. The results indicate that either acetic acid or acetate accelerates cathodic reducing reaction, facilitates dissolution of corrosion products on carbon steel, and so promotes the corrosion rate of carbon steel in carbon dioxide saturated NaCl solution. All Nyquist Plots are consisting of a capacitive loop in high frequency region, an inductive loop in medial frequency region and a capacitive arc in low frequency region. The high frequency capacitive loop, medial frequency inductive loop and low frequency capacitive arc are corresponding to the electron transfer reaction, the formation/adsorption of intermediates and dissolution of corrosion products respectively. All arc of the measured impedance reduced with the increase of the concentration of Ac-, especially HAc. However, the same phenomenon is not notable after reducing pH value by adding HCl. HAc is a stronger proton donor and can be reduced directly by electrochemical reaction firstly. Ac- can't participate in electrochemistry reaction directly, but $Ac^-$ an hydrate easily to create HAc in carbon dioxide saturated environments. HAc is as catalyst in $Co_2$ corrosion. As a result, the corrosion rate was accelerated in the presence of acetate ion even pH value of solution increased.

Anatomical knowledge of zygomatico-buccal plexus in a cadaveric study

  • Sukanya Uruwan;Chalermquan Rungsawang;Tawiwan Sareebot;Tanvaa Tansatit
    • Anatomy and Cell Biology
    • /
    • v.56 no.3
    • /
    • pp.313-321
    • /
    • 2023
  • The details of the facial nerve pattern were clearly explained in the parotid gland (PG), lateral area of the face, and periorbital areas to prevent the unexpected outcome of medical intervention. However, it remains unclear whether information about the zygomatico-buccal plexus (ZBP) in the masseteric and buccal regions. Therefore, this study aimed to help clinicians avoid this ZBP injury by predicting their common location. This study was conducted in forty-two hemifaces of twenty-nine embalmed cadavers by conventional dissection. The characteristics of the buccal branch (BB) and the ZBP were investigated in the mid-face region. The results presented that the BB gave 2-5 branches to emerge from the PG. According to the masseteric and buccal regions, the BB were arranged into ZBP in three patterns including an incomplete loop (11.9%), a single-loop (31.0%), and a multi-loop (57.1%). The mean distance and diameter of the medial line of the ZBP at the corner of the mouth level were 31.6 (6.7) and 1.5 (0.6) mm respectively, while at the alar base level were 22.5 (4.3) and 1.1 (0.6) mm respectively. Moreover, the angular nerve arose from the superior portion of the ZBP at the alar base level. The BB formed a multiloop mostly and showed a constant medial line of ZBP in an area approximately 30 mm lateral to the corner of the mouth, and 20 mm lateral to the alar base. Therefore, it is recommended that physicians should be very careful when performing facial rejuvenation in the mid-face region.

Additional Report of the Genus Asthena (Lepidoptera: Geometridae) from Korea

  • Kim, Nang-Hee;Choi, Sei-Woong;Kim, Sung-Soo
    • Animal Systematics, Evolution and Diversity
    • /
    • v.34 no.2
    • /
    • pp.92-95
    • /
    • 2018
  • After the revision of the Korean species of Asthena $H{\ddot{u}}bner$, we additionally added one new species, Asthena koreana sp. nov. and two new records, Asthena hamadryas Inoue and Asthena sachalinensis (Matsumura) from Korea. Asthena koreana sp. nov. can be characterized by the white forewing with a costally bifurcated, loop-shaped antemedial line, black minute discoidal dot and single postmedial line and white hindwing with straight antemedial line and black discoidal dot. Asthena hamadryas Inoue can be distinguished by a white forewing with a costally loop-shaped antemedial line and undulating, double lines of the postmedial line, as well as a white hindwing with four light ochreous waved lines without discoidal dots. Asthena sachalinensis can be distinguished by their whitish forewing with thick light brownish postmedial lines and minute black discoidal dot on the costal loop of the antemedial line and whitish hindwing with light brownish medial lines with minute black discoidal dot. Currently, eight species of the genus are known in Korea. We provided a revised key to the Korean species of the genus.

ELECTRICAL STIMULATION FOR THE RESTORATION OF GAIT FUNCTION IN HEMIPLEGIC PATIENTS (일측 마비환자의 전기자극에 의한 보행기능의 회복)

  • Jeong, D.H.;Park, B.R.;Kim, S.S.;Lee, C.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.203-208
    • /
    • 1992
  • In order to restore the gait function by functional electrical stimulation(FES) in hemiplegic patients, an electrical stimulator and foot sensor were developed on the basis of optimal parameters which resulted from animal experiments. Physical properties of the soleus muscle were quite different from those of themedial gastrocnemius muscle, that is, the former had a characteristic or slow muscle and the letter had a characteristic of fast muscle in rats. Optimal parameters for electrical stimulation were 0.2ms of pulse width and 20Hz of frequency in the soleus muscle and 0.3ms, 40Hz in the medial gastrocnemius muscle. Amplitude modulated electrical stimulator with -15V of maximal output was made and automatic on-off time if the stimulator was 5 seconds. The foot sensor composed of 3 sensors in 3 pressure points of the foot was made in order to control the gai t function by closed loop feedback system. The gait function was improved by using the stimulator and foot sensor in peroneal palsy. These results suggest that the electrical stimulator with closed loop feedback system may restore the gait function in hemiplegic patients.

  • PDF

Peripheral osteoma on the medial eyebrow successfully extracted while preserving supratrochlear nerve

  • Sim, Ho Seup;Lee, Dong Gyu;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.421-424
    • /
    • 2019
  • Osteomas are benign, slow-growing osteogenic lesions frequently found in the craniomaxillofacial region. They can be classified as peripheral, central, or extraskeletal. Reactive mechanisms to trauma or infection, as well as muscle traction, are thought to play a major role in the development of peripheral osteomas. In the present report, a 41-year-old woman presented with a slowgrowing, painless mass on her left eyebrow. She had suffered trauma 15 years prior. In the computed tomography scan, a 2.5×2×0.7-cm radio-opaque tumor was detected just medial to the left supraorbital foramen, and a peripheral osteoma was clinically diagnosed. An elective operation under general anesthesia was planned. Following a suprabrow incision, subcutaneous and intramuscular dissection was performed. In the surgical plane deep to the corrugator muscles and superficial to periosteum, a branch of the supratrochlear nerve was encountered and preserved using a vessel loop. The osteoma beneath the periosteum was extracted in multiple fragments using a chisel and mallet to minimize trauma to the nerve. Contour and facial symmetry were corrected. To use a suprabrow incision, the surgeon must understand neighboring anatomical structures, including the course of the supratrochlear and supraorbital neurovascular bundles. When these structures are located adjacent to tumor lesions, careful surgical maneuvers should be performed to preserve them.

Modified Inside-Out Suture Technique for Meniscus Repair (변형된Inside-Out 술식을 이용한 반월상 연골 봉합술)

  • Ahn Jin-Hwan;Wang Joon-Ho;Yoo Jae-Chul;Kim Hyung-Gun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.118-123
    • /
    • 2002
  • Purpose: To report modified technique of inside-out suture in repair of tear of postero medial corner of medial meniscus. Operative technique: Arthroscope is placed through anterolateral portal. Suture hook is delivered through anteromedial portal. By rotating the suture hook, it penetrates the inner portion of the torn meniscus from femoral surface to tibial surface of the meniscus for vertically oriented suture. A PDS suture is delivered through the lumen of suture hook, and the suture hook is withdrawn. The both ends of the suture are retrieved through anteromedial portal by a retriever, either grasper or crochet hook.A Zone-specific cannula is positioned below the inferior surface of the meniscus through anterolateral portal. The Looped Needle designed by the authors is delivered through the lumen of the Zone-specific cannula. The suture end of the tibial surface is placed in the loop of the Looped Needle and pulled out to the surface of posteromedial joint line. The suture end of the femoral surface is pulled out in same manner. A transverse skin incision of 1cm size is made adjacent to pulled out suture and the suture is tied. Discussion: Even though modified inside-out suture technique requires longer operation time than conventional inside-out technique, it provides vertically oriented suture and good tissue coaptation. The authors recommend this modified inside-out suture technique to be good alternative in repairing tear of the posteromedial corner of medial meniscus.

  • PDF

A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads

  • Kang, Minsuk;Nam, Yong Seok;Kim, In Jong;Park, Hae-Yeon;Ham, Jung Ryul;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.307-314
    • /
    • 2022
  • Objective : The percutaneous thread transection technique is a surgical dissecting method using a dissecting thread inserted through a needle under ultrasound guidance without skin incision. As the new dissecting threads were developed domestically, this cadaver study was conducted to compare the effectiveness and safety between the new threads (ultra V sswire and smartwire-01) and a pre-existing commercial dissecting thread (loop & shear) by demonstrating a modified looped thread cubital tunnel release. Methods : The percutaneous cubital tunnel release procedure was performed on 29 fresh cadaveric upper extremities. The pre-existing commercial thread was used in 5 upper extremities. The two newly developed threads were used in 24 upper extremities. Two practitioners performed the procedures separately. After the modified looped thread cubital release, anatomical and histological analyses were performed by a blinded anatomist. The presence of the dissected cubital tunnel and damaged adjacent soft tissue was assessed. Results : Out of the 29 cadaveric upper extremities, 27 specimens showed complete dissection of the Osborne ligament and the proximal fascia of the flexor carpi ulnaris muscle. One specimen was incompletely dissected in each of the ultra V sswire and smartwire-01 groups. There were no injuries of adjacent structures including the ulnar nerve, ulnar artery, medial antebrachial cutaneous nerve, or flexor tendon with either the commercial thread or the newly developed threads. The anatomical analysis revealed clear and sharp incisional margins of the cubital tunnel in the Smartwire-01 and loop & shear groups. All three kinds of threads maintained proper linear elasticity for easy handling during the procedure. The smartwire-01 provided higher visibility in ultrasound than the other threads. Conclusion : The newly developed threads were effective and safe for use in the thread cubital tunnel release procedure.

Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) - (내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) -)

  • Ahn, Jin-Hwan;Ha, Chul-Won;Kim, Ho;Kim, Sung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 1999
  • Purpose : The importance of meniscal repair is well recognized. But transeciton of the posterior horn of the medial meniscus at the posterior tibial attachment is rarely documented and known irreparable. We experienced 9 cases of transection, and present clinical features and pull out suture technique. Methods and Materials : There were 9cases of transection of the posterior horn of medial meniscus from September 1998 to July 1999 in our hospital. Age was 59.3 years in average and ranged from 38 to 70years. Clinical features and MRI made diagnosis in all cases. We confirmed the diagnosis with arthroscopy and repaired the transection with pullout suture technique. Clinical features : Transection of the posterior horn of the medial meniscus at the posterior tibia attachment occurred frequently in middle aged people. They complained posterior knee pain, but they have no history of definitive trauma. Characteristically they had difficulty in full flexion of the knee and in having a squatting position. MRI is very important in diagnosis of transection, especially in coronal view, there is separation of the posterior horn of the meniscus from the posterior tibial attachment. Surgical technique : Pullout suture technique includes debridement of fibrous or scar tissue, exposure of the subchondral bone of the posterior tibial attachment site, suture the transected end of the meniscus with PDS suture, bone tunnel formation from the anteromedial aspect of the proximal tibia, insertion of wire loop through the tibia tunnel, pull the PDS suture through the tibia tunnel out of the joint and stabilize the PDS with post-tie technique to the proximal tibia. Conclusion : Transection of the posterior horn of the medial meniscus at the posterior tibial attachment is not common clinically and rarely documented. Clinical features and MRI are very important in diagnosis of this type tear. Arthroscopic pullout sutures is useful for treatment of this type tear of the meniscus.

  • PDF