• Title/Summary/Keyword: Media Flow

Search Result 944, Processing Time 0.029 seconds

Case Studies for Nanomaterials' Exposure to Environmental Media (나노물질의 환경 매질별 노출 사례 조사)

  • Umh, Ha Nee;Roh, Jinkyu;Lee, Byoung-Cheun;Park, Sumin;Yi, Jongheop;Kim, Younghun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1056-1063
    • /
    • 2012
  • Recent rapidly growth in nanotechnolgies is promised novel benefits through the exploitation of their unique industrial and biomedical applications. With increasing utilization of nanomaterials in consumer products, the potential release of nanomaterials into the environment and their impacts on the ecosystem and human health have been the issues of concern. Nanomaterials that was exposed unintentionally in environment might be accumulated in various environmental media, and finally it will be influenced to human and ecosystems. Therefore, it is important to understand the fate and behavior of nanoparticles for understanding effects on environmental media (air, water, and soil phase). Therefore, in this work, we investigated the several cases for environmental exposure of nanomaterials and suggested the direction of further research. In workplace, exposure to air media is dominant, but finally waste and wastewater was moved to the water and soil phase. In addition, we found the existing sewage treatment plant was not suitable to remove completely nanomaterials in wastewater flow. To deeper study, environmental monitoring tool must be developed additionally and we suggested the several analyzing method for aged and pristine physicochemical properties of nanomaterials exposed into environmental media. This review for nanomaterials' exposure to environmental media will be helpful to investigate the environmental fate of nanomaterials and define the suitable treatment method for nano-waste.

A Method of Pedestrian Flow Speed Estimation Adaptive to Viewpoint Changes (시점변화에 적응적인 보행자 유동 속도 측정)

  • Lee, Gwang-Gook;Yoon, Ja-Young;Kim, Jae-Jun;Kim, Whoi-Yul
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.409-418
    • /
    • 2009
  • This paper proposes a method to estimate the flow speed of pedestrians in surveillance videos. In the proposed method, the average moving speed of pedestrians is measured by estimating the size of real-world motion from the observed motion vectors. For this purpose, a pixel-to-meter conversion factor is introduced which is calculated from camera parameters. Also, the height information, which is missing because of camera projection, is predicted statistically from simulation experiments. Compared to the previous works for flow speed estimation, our method can be applied to various camera views because it separates scene parameters explicitly. Experiments are performed on both simulation image sequences and real video. In the experiments on simulation videos, the proposed method estimated the flow speed with average error of about 0.08m/s. The proposed method also showed promising results for the real video.

A Study on Performance Characteristics of an Evaporative Heat Exchanger with Mini-channels (환경조절장치용 미세유로형 증발열교환기의 성능특성 연구)

  • Lee, Hyung-Ju;Yoo, Young-June;Min, Seong-Ki;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.247-253
    • /
    • 2011
  • An experimental study on performance characteristics of an evaporative heat exchanger based on tests for various operating conditions was presented. The heat exchanger maximizes the heat transfer rate per unit volume by applying mini-channels for both the air and coolant flow paths, and minimizes the amount of the coolant by using its latent heat of evaporation. The heat exchanger was manufactured by etching the flow paths, brazing the heat exchange plates, and welding the in/out ports of the media. The basic performance test has confirmed that the heat exchanger met its design requirements, and the results of the map test were analyzed to produce the performance characteristics quantitatively depending on the air inlet temperature, the air flow rate, and the coolant flow rate.

  • PDF

The Effects of 4CID Model based Robot Programming Learning on Learners' Flow Level (4CID 모델 기반 로봇 활용 프로그래밍 학습의 몰입 효과 분석)

  • Lee, EunKyoung;Lee, YoungJun
    • The Journal of Korean Association of Computer Education
    • /
    • v.11 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • Using robots in the programming classes may help to induce learners' interest and motivation. However, simple introduction of new media, such as robots, may cause to increase learners' interest level temporarily, but also may give cognitive overload and offense against learning motivation. We developed a robot programming course to induce intrinsic motivation and to reduce cognitive load for learners in the programming education. And then, we implemented the developed course in college programming classes and analysed the educational effects of robot programming learning on novice learners' flow level. We found that robot programming course was helpful in enhancing novice learners' flow level. Especially, the element of 'autotelic experience', which explains an intrinsic motivation, was higher than conventional programming course group. It means that the developed strategies for robot programming course provides positive effects on learners' intrinsic motivation.

  • PDF

Experimental and computational analysis of behavior of three-way catalytic converter under axial and radial flow conditions

  • Taibani, Arif Zakaria;Kalamkar, Vilas
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.134-142
    • /
    • 2012
  • The competition to deliver ultra-low emitting vehicles at a reasonable cost is driving the automotive industry to invest significant manpower and test laboratory resources in the design optimization of increasingly complex exhaust after-treatment systems. Optimization can no longer be based on traditional approaches, which are intensive in hardware use and laboratory testing. The CFD is in high demand for the analysis and design in order to reduce developing cost and time consuming in experiments. This paper describes the development of a comprehensive practical model based on experiments for simulating the performance of automotive three-way catalytic converters, which are employed to reduce engine exhaust emissions. An experiment is conducted to measure species concentrations before and after catalytic converter for different loads on engine. The model simulates the emission system behavior by using an exhaust system heat conservation and catalyst chemical kinetic sub-model. CFD simulation is used to study the performance of automotive catalytic converter. The substrate is modeled as a porous media in FLUENT and the standard k-e model is used for turbulence. The flow pattern is changed from axial to radial by changing the substrate model inside the catalytic converter and the flow distribution and the conversion efficiency of CO, HC and NOx are achieved first, and the predictions are in good agreement with the experimental measurements. It is found that the conversion from axial to radial flow makes the catalytic converter more efficient. These studies help to understand better the performance of the catalytic converter in order to optimize the converter design.

Hazard Prevention Using Multi-Level Debris Flow Barriers (다단식(多段式) 유연성 토석류 방지시설에 관한 적용성 검토 연구)

  • Baek, Yong;Choi, Youngchul;Kwon, Oil;Choi, Seungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.15-23
    • /
    • 2010
  • Debris flows are a natural hazard which looks like a combination of flood, land and rock slide. Large rainfall in July 2006 produced several large scale debris flows and many small debris flows that resulted in loss of life and considerable property and railway damage, as was widely reported in the national media. The hazard "debris flow" is still insufficiently researched. Furthermore debris flows are very hard to predict. Flexible Ring net barriers are multi-functional mitigation devices commonly applied to rock fall or floating wood protection in floods, snow avalanches and also mud flows or granular debris flows, if properly dimensioned for the process or processes for which they are intended. Overtopping of the barriers by debris flows and sediment transport is possible, supporting the design concept that a series of barriers may be used to stop volumes of debris larger than are possible using only one barrier. The future for these barrier concepts looks promising because these barriers represent the state of art for such applications and are superior to many other available options.

Simulation study of DAF flotation basin using CFD (전산유체해석기법을 이용한 용존공기부상공정의 유동해석)

  • Park, Byungsung;Woo, Sungwoo;Park, Sungwon;Min, Jinhee;Lee, Woonyoung;You, Sunam;Jun, Gabjin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.

Analysis of Membrane Integrity and Mitochondrial Activity in Fresh and Cryopreserved Boar Sperm Using Flow Cytometry

  • Park C. S.;Li Z. H.;Sung N. D.;Jin D. I.;Cong P. Q.;Kim E. S.;Song E. S.;Yi Y. J.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.4
    • /
    • pp.253-257
    • /
    • 2005
  • This study was carried out to evaluate the effects of washing medium, breed and washing temperature of fresh and frozen-thawed boar sperm on mitochondrial activity and membrane integrity by flow cytometry. More than $80\%$ of fresh sperm washed with mTLP-PVA medium at $20^{\circ}C$ exhibited an intact membrane and a functional mitochondrion. With frozen-thawed samples, a large number of sperm showed both damaged membrane $(36.4\~46.9\%)$ and nonfunctional mitochondrion $(55.1\~71.1\%)$ in the mTLP-PVA and BTS washing media at $20^{\circ}C$. There were no breed effects of fresh and frozen-thawed sperm on mitochondrial activity and membrane integrity. The percentages of damaged membrane of fresh and frozen sperm, respectively, were higher at $4^{\circ}C$ washing temperature than at $20^{\circ}C$ washing temperature in the mTLP-PVA medium. We found that washing medium and washing temperature of fresh and frozen-thawed boar sperm were important for the analyses of mitochondrial activity and membrane integrity by flow cytometry.

The involvement of ginseng berry extract in blood flow via regulation of blood coagulation in rats fed a high-fat diet

  • Kim, Min Hee;Lee, Jongsung;Jung, Sehyun;Kim, Joo Wan;Shin, Jae-Ho;Lee, Hae-Jeung
    • Journal of Ginseng Research
    • /
    • v.41 no.2
    • /
    • pp.120-126
    • /
    • 2017
  • Background: The present study investigated the effect of ginseng berry hot water extract (GBx) on blood flow via the regulation of lipid metabolites and blood coagulation in rats fed a high-fat diet (HFD). Methods: Sixty rats were divided into five groups in descending order of body weight. Except for the control group, the other four groups were fed a HFD containing 45% kcal from fat for 11 wk without GBx. GBx groups were then additionally treated by gastric gavage with GBx dissolved in distilled water at 50 (GBx 50) mg/kg, 100 (GBx 100) mg/kg, or 150 (GBx 150) mg/kg body weight for 6 wk along with the HFD. To investigate the effects of GBx on rats fed a HFD, biochemical metabolite, blood coagulation assay, and histological analysis were performed. Results: In the experiments to measure the serum levels of leptin and apolipoprotein B/A, GBx treatment attenuated the HFD-induced increases in these metabolites (p < 0.05). Adiponectin and apolipoprotein E levels in GBx-treated groups were significantly higher than the HFD group. Prothrombin time and activated partial thromboplastin time were increased in all GBx-treated groups. In the GBx-treated groups, the serum levels of thromboxane $A_2$ and serotonin were decreased and concentrations of serum fibrinogen degradation products were increased (p < 0.05). Moreover, histomorphometric dyslipidemia-related atherosclerotic changes were significantly improved by treatment with GBx. Conclusion: These results suggest the possibility that GBx can ameliorate blood flow by decreasing intima-media thickness via the regulation of blood coagulation factors related to lipid metabolites in rats fed a HFD.

On-site Evaluation of Rainwater Harvesting Device for Securing Irrigation Water in Small Fields (소규모 밭 관개용수 확보를 위한 소류천 빗물 집수장치의 현장 평가)

  • Choi, Yonghun;Kim, Youngjin;Kim, Minyoung;Jeon, Jonggil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.1
    • /
    • pp.31-36
    • /
    • 2018
  • A rainwater harvesting device was developed for runoff flow harvesting in a small stream or channel and its performance was evaluated in small fields. The rainwater harvesting device has slits on its side of cylindrical volume in 15 cm diameter and 70 cm length, which is designed to increase its water flow harvesting capacity. The maximum collectable water quantity was about 0.0022 ton/sec (130 L/min). Rainwater harvesting device were installed in two locations (P1, P2). P1 is a point for rainfall runoff flow harvesting. P2 is a point for ordinary flow harvesting. During this study, total rainfall depth was 334.5 mm. Runoff of 1,722 ton and 7,984 ton occurred in P1 and P2, and 273 ton and 125 ton were collected by this rainwater harvesting device. Harvesting efficiency was calculated as 15.85 % and 1.57 % in P1 and P2. Clogging of screen filter media in the cylinder due to soil and suspended solids has lowered the harvesting efficiency. However, it was possible to harvest 30 ton/month of rainwater harvesting and it is expected that it will help to solve short-term water shortage.