• 제목/요약/키워드: MedX

검색결과 70건 처리시간 0.025초

신경회로망을 이용한 흉부 X-선 영상에서의 폐 영역분할 (Lung Area Segmentation in Chest Radiograph Using Neural Network)

  • 김종효;박광석;민병구;임정기;한만청;이충웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 춘계학술대회
    • /
    • pp.33-37
    • /
    • 1990
  • In this paper, a new method for lung area segmentation in chest radiographs has been presented. The movivation of this study is to include fuzzy informations about the relation between the image date structure and the area to be segmented in the segmentation process efficiently. The proposed method approached the segmentation problem in the perspective of pattern classification, using trainable pattern classifier, multi-layer perceptron. Having been trained with 10 samples, this method gives acceptable segmentation results, and also demonstrated the desirable property of giving better results as the training continues with more training samples.

  • PDF

Mn-Mg-Fe 계 산화물 조성의 저항-온도 특성 (Resistivity-Temperature Properties of Mn-Mg-Fe Oxide Systems)

  • 이승관;김종령;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 2000
  • (M $n_{l-x}$M $g_{l-x}$)F $e_{2+x}$ $O_4$(x=0.0, 0.025, 0.1, 0.2) for NTC(negative temperature coefficient) thermistor was prepared by calcining at 80$0^{\circ}C$ and sintering at from 1100 to 130$0^{\circ}C$ with 5$0^{\circ}C$ intervals while x was varied from 0.0 to 0.025, 0.1 and 0.2. The best linear property was obtained in the based specimen sintered at 120$0^{\circ}C$ with x=0.1 composition. Thermistor parameter, $B_{25~85^{\circ}C}$, was in the range of 5000~ 7300 [K]. Temperature coefficient of resistance, $\alpha$$_{25^{\circ}C}$, was -5.2 %/$^{\circ}C$. The results showed the possibility that Mn-Ni-Co based thermistor could be substituted by the composition used in this study was confirmed.med.d.

  • PDF

X-band PSInSAR를 위한 고정산란체 추출 및 네트워크 분석 기법 (Persistent Scatterer Selection and Network Analysis for X-band PSInSAR)

  • 김상완;조민지
    • 대한원격탐사학회지
    • /
    • 제27권5호
    • /
    • pp.521-534
    • /
    • 2011
  • 최근 TerraSAR-X SAR, TanDEM-X 또는 COSMO-SkyMed와 같은 1 m 급의 고해상도 X-band SAR 센서를 탑재한 인공위성이 발사되어 운행되고 있다. 국내에서도 X-band를 탑재한 1m 급의 고해상도 위성 레이더인 KOMPSAT-5가 발사될 예정에 있다. 본 연구는 X-band SAR 영상을 이용한 PSInSAR 기법 적용에 보다 적합한 고정산란체 추출 및 네트워크 생성 기법을 개발하였다. 새로운 PSC 추출 알고리즘은 다음 두 단계로 구성되어 있다. 첫 번째 진폭분산지수, 평균반사강도, 평균긴밀도를 복합적으로 이용하여 초기 PSC를 선출한다. 두 번째 초기 선출된 PSC의 네트워크 분석을 통해 추정된 각 PSC에서의 시계열 긴밀도를 직접 이용하여 최종 추출한다. 또한 PSC를 이용한 네트워크 분석의 안정성을 높이기 위한 multi-TIN 구성 기법과 비 도심지역에서 분석 신뢰도를 높이기 위한 복합 네트워크를 제안하였다. 개발된 알고리즘을 뉴올리언즈 지역에서 획득된 21개의 TerraSAR-X SAR 자료에 적용한 결과, 기존의 PSInSAR 기법으로는 관측되지 않았던 비 도심지역에서 다수의 PS가 추출되어 변위 속도 분석이 가능하였다. 이러한 결과는 주로 도심지역에서 널리 사용되어 왔던 PSInSAR 기법을 비 도심지역으로까지 확대하는 것으로, 향후 KOMPSAT-5를 활용한 한반도 지역 상시 모니터링에 기여할 것이다.

DEM 품질에 따른 고해상도 SAR 영상의 지형 보정 정확도 평가 (Accuracy Evaluation of Terrain Correction of High Resolution SAR Imagery with the Quality of DEM)

  • 이경엽;변영기;김윤수
    • 한국측량학회지
    • /
    • 제30권6_1호
    • /
    • pp.519-528
    • /
    • 2012
  • SAR는 기상상태와 태양고도 제약을 받지 않고 영상을 취득할 수 있는 장점을 갖지만 측면 관측 촬영방식으로 인해 고도에 의한 왜곡이 발생하여 광학영상과의 통합적 활용을 위해서는 지형 보정 작업이 필수적이다. 일반적으로 SAR 영상의 지형보정은 대상지역의 수치표고모델(Digital Elevation Model, DEM)을 사용하여 수행되기 때문에 DEM 품질이 지형보정 정확도에 미치는 영향에 대한 평가가 이루어져야 한다. 이를 위해 본 연구에서는 1:5000 수치지도로부터 제작한 DEM, LiDAR DEM, ASTER GDEM, SRTM DEM을 비교 분석하여 고해상도 SAR 영상의 지형보정에 적합한 DEM을 탐색하였다. 실험데이터로는 KOMPSAT-5호와 동일한 고해상도 X-band SAR 시스템을 장착한 TerraSAR-X와 Cosmo-SkyMed 영상을 사용하였다. 지형보정 결과 평가를 위해 동일지역의 KOMPSAT-2 정사영상과의 정량적 비교평가를 수행하였다. 실험결과 수치지도로 제작한 DEM이 가장 정확한 지형보정 결과를 보였으며 현업에서 가장 많이 활용되고 있는 SRTM DEM의 경우 고해상도 SAR 영상의 지형보정에는 부적합 하였다.

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

X선 CT화상을 이용한 사상체질의 형태학적 특징 파라메타의 제안 (Suggestion of the morphological characteristic parameters according to the Lee's physical constitution theory using X-ray computed tomography)

  • 조봉관;배종일;고병희;제등정남
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.13-16
    • /
    • 1993
  • In this paper the morphological characteristic parameters according to the Lee's physical constitution theory are suggested using the X-ray computed tomography. The Lee's physical constitution theory is classify into 4 physical constitutional types by the relative degree of visceral function: those are macro-negative(strong liver- weak lung), micro-negative(strong kidney- weak spleen), micro-positive(strong spleen- weak kidney) and macro-positive(string lung- weak liver). The morphological characteristic parameters are the following. The AA-line is the distance between Rt. & Lt. acupuncture point keug-cheun. The BB-line is the length of lung. The CC-line is the longest width of thorax. The DD-line is the vertical distance between the CC-line and the EE-line. The EE-line is the distance between the Rt. and Lt. anterior superior iliac spines. As the results macro-negative(strong liver-weak lung) has the longest CC-line and the short BB-line. Micro-negative(strong kidney-weak spleen) has the longest EE-line and the short CC-line. Micro-positive(strong spleen-weak kidney) has the longest DD-line and the short BB-line. And macro-positive(strong lung-weak kidney) has the longest BB-line and the short EE-line.

  • PDF

위성 SAR 영상과 AIS을 활용한 선박 탐지 (Vessel Detection Using Satellite SAR Images and AIS Data)

  • 이경엽;홍상훈;윤보열;김윤수
    • 한국지리정보학회지
    • /
    • 제15권2호
    • /
    • pp.103-112
    • /
    • 2012
  • SAR(Synthetic Aperture Radar) 영상과 AIS(Automatic Identification System) 자료를 활용하여 선박 탐지 실험을 수행하였다. 2010년 5월, 2주간 서해안(인천 근해)의 다중시기 해외위성 SAR 영상인 TerraSAR-X, Cosmo-SkyMed(X-밴드), Radarsat-2(C-밴드)와 AIS 자료를 이용하였다. SAR 영상 분석을 위해 해양과 선박의 산란 특성과 SAR 영상과 AIS 자료의 기초 처리 방법을 기술하였다. 선박 식별을 위해서 임계값 설정 기법을 사용하였다. 선박 탐지 결과로 시계열 변화 탐지와 AIS 연동 선박 탐지 사례를 보인다. 이 결과를 통해 위성 SAR 영상과 AIS를 이용한 선박 탐지는 해양 관리에 유용하게 사용될 수 있을 것으로 사료된다.

도심지역 DSM을 이용한 고해상도 InSAR 위상 시뮬레이션 (High Resolution InSAR Phase Simulation using DSM in Urban Areas)

  • 윤근원;김상완;이용웅;이동천;원중선
    • 대한원격탐사학회지
    • /
    • 제27권2호
    • /
    • pp.181-190
    • /
    • 2011
  • 현재 공간해상도 약 1 m 의 고해상도 X-band SAR 위성인 독일의 TerraSAR-X와 TanDEM-X, 이탈리아의 COSMO-SkyMed가 성공적으로 발사되어 운용되고 있으며 분석 결과 우수한 성능을 보이고 있다. 국내에서도 최고 공간해상도 약 1 m 의 X-band SAR 위성인 KOMPSAT-5가 향후 발사될 예정이다. 이러한 고해상도 SAR 영상 활용이 가능해짐에 따라 SAR Interferometry(InSAR) 기술을 이용한 도심지역 모니터링이 더욱 관심을 받고 있다. 하지만 기존의 InSAR 위상 시뮬레이션 알고리즘은 도심지역에 분포하는 빌딩과 같은 인공구조물 객체에 의해 나타나는 layover 현상과 빌딩 벽면에서 산란되는 신호를 충분히 고려하지 못한다. 본 연구에서는 기존 알고리즘의 한계점을 극복하기 위하여 LIDAR DSM을 이용한 정밀 InSAR 위상과 SAR 반사강도 영상 시뮬레이션 알고리즘을 개발하였다. 대전 지역에서 획득된 TerraSAR-X spotlight 영상과 비교 분석을 통해 개발된 알고리즘의 타당성 분석을 수행하였다. 시뮬레이션 결과로 생성된 InSAR 위상과 SAR 반사강도 영상은 실제 TerraSAR-X spotlight SAR 자료로부터 생성된 결과와 매우 유사하였다. 이러한 결과는 향후 고해상도 SAR 영상을 이용한 도심지역 변화 및 변위탐지 모니터링 연구에 활용될 것이다.