• 제목/요약/키워드: Mechanism of monitoring

검색결과 664건 처리시간 0.033초

음향방출을 이용한 콘크리트 부재의 미시적 파괴특성의 On-Line Monitoring (On-Line Monitoring of Microscopic Fracture Behavior of Concrete Using Acoustic Emission)

  • 이준현;이진경;장일영;윤동진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.677-682
    • /
    • 1998
  • Concrete is an inhomogeneous material consisting of larger aggregates and sand embedded in a cement paste matrix. In this study, an acoustic emission technique has been used to clarify the microscope failure mechanisms of concrete under three point bending test. AE source location has also been done to monitor the activities of internal damage and the progress of microscopic failure path during the loading. The relationship between AE characteristic and microscopic and microscopic failure mechanism is discussed.

  • PDF

Abrasive Waterjet 세라믹 Drilling가공시 Acoustic Emission 신호를 이용한 On-Line Monitoring에 대한 연구 (On-Line Monitoring of Abrasive Water Jet Drilling of Refractory Ceramics Using Acoustic Emission Sensing Technique)

  • Kwak, Hyo-Sung;Rodovan Kovacevic
    • 한국정밀공학회지
    • /
    • 제15권6호
    • /
    • pp.48-57
    • /
    • 1998
  • Abrasive waterjet(AWJ)은 가공시 열에 의한 가공경화가 없기 때문에 유리, 세라믹, 타이타늄및 금속복합재료와 같은 난삭재의 가공기술로 사용이 증가되었다. Acoustic emission(AE)신호에 의한 AWJ 세라믹 drilling가공시 On-Line Monitoring의 가능성이 고찰되었다. 기계 적인 물성이 서로 상이한 3종류의 세라믹이 본 연구에서 사용되었으며, AE신호는 AWJ drilling의 깊이를 monitoring하는데 유용함을 알 수 있었고 또한 세라믹의 material removal mechanisms을 규명하였다.

  • PDF

Caisson식 방파제의 손상 모니터링 기법 (Damage monitoring scheme of caisson-type breakwaters)

  • 박재형;이병준;이용환;김주영;김정태
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.151-156
    • /
    • 2004
  • 최근 국내외에서 국제무역 물량의 증대에 따라 대규모 항만 건설 공사가 진행되고 있으며, 이에 경제성, 시공성이 뛰어난 Caisson 형식의 구조물이 많이 사용되어지고 있다. 특히 항만 및 어항의 외곽시설인 방파제는 계류선박의 안전과 하역 및 적화를 용이하게 하는 중요한 구조물이다. 따라서, 본 연구에서는 Caisson식 방파제에 태풍, 충격력과 같은 몇 가지 외력 조건에 대하여 구조 해석을 실시하여 손상메커니즘을 분석하였다 이러한 손상 메커니즘에 따라 손상을 인위적으로 발생시켜 손상 위치 탐색을 수행하였다.

  • PDF

A LOCAL-GLOBAL VERSION OF A STEPSIZE CONTROL FOR RUNGE-KUTTA METHODS

  • Kulikov, G.Yu
    • Journal of applied mathematics & informatics
    • /
    • 제7권2호
    • /
    • pp.409-438
    • /
    • 2000
  • In this paper we develop a new procedure to control stepsize for Runge- Kutta methods applied to both ordinary differential equations and semi-explicit index 1 differential-algebraic equation In contrast to the standard approach, the error control mechanism presented here is based on monitoring and controlling both the local and global errors of Runge- Kutta formulas. As a result, Runge-Kutta methods with the local-global stepsize control solve differential of differential-algebraic equations with any prescribe accuracy (up to round-off errors)

케이블-기반 개폐식 지붕의 모니터링을 위한 영상 전송 장치 개발 (Development of Video Transmission Device for Monitoring of a Cable-Based Retractable Roof)

  • 안수홍;손수덕;이승재;강주원
    • 한국공간구조학회논문집
    • /
    • 제19권4호
    • /
    • pp.103-110
    • /
    • 2019
  • The cable-based retractable membrane roof makes it impossible to maintain its shape and stiffness during driving process, unlike the hard-type retractable roof. Consequently, monitoring using a relatively simple wireless video transmission device is required. However, since video data has a bigger transmission rating than other monitoring data in terms of the structure velocity or acceleration, there is a need to develop transmission device that is easy to install and entails low maintenance cost. This paper studies on a real-time video transmission system for monitoring the cable-based retractable membrane roof while driving. A video transfer software, using the mobile network, is designed and the embedded system is constructed. Ultimately, the data transmission server is tested. Connecting a trolley to the system allows testing of the validity and efficiency of the developed system through the video data transmitted in the driving process. Result of the test shows that the developed system enables multi-device data transfer with monitoring via the mobile network.

다중 분류 시스템을 이용한 가전기기 식별 알고리즘 (Appliance identification algorithm using multiple classifier system)

  • 박용순;정태윤;박성욱
    • 대한임베디드공학회논문지
    • /
    • 제10권4호
    • /
    • pp.213-219
    • /
    • 2015
  • Real-time energy monitoring systems is a demand-response system which is reported to be effective in saving energy up to 12%. Real-time energy monitoring system is commonly composed of smart-plugs which sense how much electrical power is consumed and IHD(In-Home Display device) which displays power consumption patterns. Even though the monitoring system is effective, users should themselves match which smart plus is connected to which appliance. In order to make the matching work to be automatic, the monitoring system need to have appliance identification algorithm, and some works have made under the name of NILM(Non-Intrusive Load Monitoring). This paper proposed an algorithm which utilizes multiple classifiers to improve accuracy of appliance identification. The algorithm proposes to understand each classifiers performance, that is, when a classifier make a result how much the result is reliable, and utilize it in choosing the final result among result candidates from many classifiers. By using the proposed algorithm this paper make 4.5% of improved accuracy with respect to using single best classifier, and 2.9% of improved accuracy with respect to other method using multiple classifiers, so called CDM(Commitee Decision Mechanism) method.

가전제품 화재 메커니즘 재현 및 분석을 위한 인프라 구축 (The Infrastructure Case for Reproduction or Analysis of The Mechanism on The Fire of The Electrical Appliances)

  • 장인혁;이창훈;이영주;임홍우
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.60-66
    • /
    • 2015
  • In this paper, The infrastructure case for reproduction or analysis of the mechanism on the fire or the electrics shock of the electrical appliances is proposed. The various electrical appliances(Washing machine, Ballast, Electric heaters, Electronic switches, Mobile phone chargers) used in the home can be tested on the high voltage and over current test through the implementation of the infrastructure. The electrical tests of fire and electric shock consists of the high voltage of maximum 5000 V and over current test of 3 steps(90 A, 60 A, 40 A) and noise test. The mechanism of the fire and the electric shock tests reproduced are analyzed through the monitoring system and the oscilloscope. The electronics manufacturers can prevent accidents through the tests of the electronics factor reproduced and the analysis of the infrastructure designed.

환청의 기전과 신경해부학 (Mechanism and Neuroanatomy of Auditory Hallucination)

  • 이승환;서광윤
    • 수면정신생리
    • /
    • 제8권2호
    • /
    • pp.98-106
    • /
    • 2001
  • Auditory hallucinations are cardinal feature of psychosis. But the mechanism of hallucinated speech is unknown. The hypothesis that these hallucinations arise from pathologically altered brain monitoring system underlying speech perception is influential. With the help of rapidly developing neuroimaging study technologies, many researchers have been finding new organic deficits in the hallucinated schizophrenic patient's brain. In this article, we reviewed the general appearance of hallucination, a computer simulation model of hallucination and several neuroimaging study findings on hallucinating schizophrenic patients. In conclusion, we presented the presumptive mechanism of hallucination based on the anatomical dysfunction of schizophrenia.

  • PDF

원전 펌프의 성능저하 특성 (Degradation characteristics of pumps in nuclear power plants)

  • 이도환;박성근;홍성대;이병학
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.593-598
    • /
    • 2008
  • In the present study, degradation characteristics of pumps in nuclear power plants were investigated to provide the information of degradation mechanism and stressors. The failure records of pumps for the periods 2000 to 2006 on INPO(Institute of Nuclear Power Operations) EPIX(Equipment Performance and Information Exchange System) DB were reviewed. The 1,834 failure records reveal that the critical areas of pump failures are bearing, mechanical seal, gasket/o-ring, shaft, impeller, coupling and packing. Based on the failure rate of critical areas, the important degradation mechanism and stressors were determined. Additionally, the relationship between degradation mechanism and stressors such as wear was examined. Finally, the monitoring parameters related to degradation and stressors were discussed for the future development of degradation evaluation and prognosis technology of pumps.

  • PDF

무선 센서 네트워크에서 트래픽 적응적인 wakeup 제어 메커니즘 (Traffic Adaptive Wakeup Control Mechanism in Wireless Sensor Networks)

  • 김혜윤;김성철;전준헌;김중재
    • 한국멀티미디어학회논문지
    • /
    • 제17권6호
    • /
    • pp.681-686
    • /
    • 2014
  • In this paper, we propose a traffic adaptive mechanism that controls the receiver's wakeup periods based on the generated traffic amounts. The proposed control mechanism is designed for military, wild animal monitoring, and forest fire surveillance applications. In these environments, a low-rate data transmission is usually required between sensor nodes. However, continuous data is generated when events occur. Therefore, legacy mechanisms are ineffective for these applications. Our control mechanism showed a better performance in energy efficiency compared to the RI-MAC owing to the elimination of the sender node's idle listening.