• Title/Summary/Keyword: Mechanical recovery system

Search Result 308, Processing Time 0.108 seconds

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Separate type heat pipe performance comparison by the heat exchanger shapes (열교환기 형상에 따른 분리형 히트파이프 성능 비교)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.723-729
    • /
    • 2016
  • This study compared fin-tube and parallel-flow heat pipes for their sensible heat exchange rate, heat recovery amount, and air-side pressure drop. Tests were done with different refrigerant charging rates of 40-60% vol. and air flow rates of 300-1,400. The sensible heat exchange rate was highest for both types of heat pipes at a working fluid charge of 40% vol. and low flow rate. For the parallel-flow heat pipe, the 60% vol. charge is too high and results in a low sensible heat exchange rate. The reason is that the thicker liquid film of the tube wall deteriorates the heat transfer effect. Hence, the optimal charging rate is 40 to 50% vol. The evaporator heat pipe has a larger air-side pressure drop than the condenser section heat pipe. The reason is considered to be condensation water arising from the evaporator surface. Compared to the fin-tube heat pipe, the parallel-flow heat pipe showed better performance with a working fluid charging rate of 48%, volume of 41%, and an air-side pressure drop about 37%.

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

Preparation of Pt Catalysts for 2-propanol Dehydrogenation using Sol-gel Method (솔-젤법을 이용한 2-propanol 탈수소화 반응 Pt 촉매의 제조)

  • Lee, Yeong-Kweon;Lee, Hwaung;Song, Hyung Keun;Na, Byung-Ki
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.328-334
    • /
    • 2007
  • Chemical heat pump system of 2-propanol/acetone/hydrogen is most suitable to the recovery of waste heat of power plant. various types of 5 wt% Pt-alumina catalysts were prepared for 2-propanol dehydrogenation using sol-gel method. The characteristics and the dehydrogenation reaction rate of each catalyst were investigated. Pt-alumina xerogel catalyst has excellent reaction rate and good durability in comparison with the existing alumina supported Pt catalysts. Pt-alumina aerogel catalyst had the highest reaction rate in all prepared catalysts, but sufficient aging time was necessary to maintain its reaction rate. A potential advantage of the aerogel catalyst is the fact that the high temperature heat treatment is not required. Without heat treatment or with low temperature heat treatment, the Pt-alumina aerogel catalyst has excellent reaction rate as well as durability and this gives us the economic advantage. Alumina xerogel supported Pt catalyst prepared by incipient wetness method showed good reaction rate, and had good mechanical strength. Blank alumina xerogel prepared by sol-gel method can be used for the support of metal catalysts.

Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

  • Kim, Tae-Hun;Park, Kay-Hyun;Yoo, Jae Suk;Lee, Jae Hang;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Background: With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. Materials and Methods: A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. Results: The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: $11.0{\pm}7.8%$ in the complex AVR group and $12.3{\pm}8.0%$ in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass ($152.4{\pm}52.6$ minutes vs. $109.7{\pm}22.7$ minutes, p=0.001), the quantity of allogenic blood products did not differ ($13.4{\pm}14.7$ units vs. $13.9{\pm}11.2$ units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ${\geq}5$ units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ${\geq}24$ hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. Conclusion: AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

Multisystem Inflammatory Syndrome in Children (MIS-C) (소아 다기관 염증 증후군)

  • Lee, Joon Kee;Cho, Eun Young;Lee, Hyunju
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.66-81
    • /
    • 2021
  • The coronavirus disease 2019 pandemic has been continuously spreading throughout the world. As of July 15, 2021, there have been more than 188 million confirmed cases and more than 4.06 million deaths. Although the incidence of severe infections is relatively low in children and adolescents compared to adults, a complication called multisystem inflammatory syndrome in children (MIS-C) may occur in some cases at approximately 2-6 weeks after severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection. MIS-C can be seen in patients of various ages, from young infants to adolescents, and may present with diverse clinical manifestations. While fever present in a great majority of patients, symptoms suggesting the involvement of the digestive or nervous system and the skin and mucous membranes (Kawasaki disease-like symptoms) also appear in many cases. Cardiac involvement may also be observed, including left ventricular dysfunction, myocarditis, coronary artery dilatation, and coronary aneurysm. In some cases, hypotension or shock can occur, and mechanical ventilation or treatment in the intensive care unit may be necessary. Fortunately, recovery is generally reported after appropriate treatment. MIS-C is a rare but important complication of SARS-CoV-2 infection in children and adolescents. As such, it is important to recognize the clinical symptoms and provide appropriate treatment at an early stage. In this review, the epidemiology, clinical symptoms, suggested pathophysiology, diagnostic approach, and treatment of MIS-C will be discussed.

Improvement of the Efficacy Test Methods for Hand Sanitizers (Gel, Liquid, and Wipes): Emerging Trends from in vivo/ex vivo Test Strategies for Application in the Hand Microbiome (손소독제(겔형, 액제형, 와이프형)의 효능 평가법 개선: 평가 전략 연구 사례 및 손 균총 정보 활용 등 최근 동향)

  • Yun O;Ji Seop Son;Han Sol Park;Young Hoon Lee;Jin Song Shin;Da som Park;Eun NamGung;Tae Jin Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Skin sanitizers are effective in killing or removing pathogenic microbial contaminants from the skin of food handlers, and the progressive growth of consumer interest in personal hygiene tends to drive product diversification. This review covers the advances in the application of efficacy tests for hand sanitizers to suggest future perspectives to establish an assessment system that is optimized to each product type (gel, liquid, and wipes). Previous research on the in vivo simulative test of actual consumer use has adopted diverse experimental conditions regardless of the product type. This highlights the importance of establishing optimal test protocols specialized for the compositional characteristics of sanitizers through the comparative analysis of test methods. Although the operational conditions of the mechanical actions associated with wiping can affect the efficacy of the removal and/or the inactivation of target microorganisms from the skin's surface, currently there is a lack of standardized use patterns for the exposure of hand sanitizing wipes to skin. Thus, major determinants affecting the results from each step of the overall assessment procedures [pre-treatment - exposure of sanitizers - microbial recovery] should be identified to modify current protocols and develop novel test methods. The ex vivo test, designed to overcome the limited reproducibility of in vivo human trials, is also expected to replicate the environment for the contact of sanitizers targeting skin microorganisms. Recent progress in the area of skin microbiome research revealed distinct microbial characteristics and distribution patterns after the application of sanitizers on hands to establish the test methods with the perspectives on the antimicrobial effects at the community level. The future perspectives presented in this study on the improvement of efficacy test methods for hand sanitizers can also contribute to public health and food safety through the commercialization of effective sanitizer products.

Early Result of Surgical Management of the Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery (관상동맥-폐동맥 이상 기시증에 대한 수술의 조기 결과)

  • Yoon Yoo Sang;Park Jeong Jun;Yun Tae Jin;Kim Young Hwue;Ko Jae Kon;Park In Sook;Seo Dong Man
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.18-27
    • /
    • 2006
  • Background: Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital anomaly, but is one of the most common causes of myocardial ischemia which would result in high mortality within the first year of life. This is our early result of the surgical management for these patients. Material and Method: From June 1989 to July 2003, 6 patients with ALCAPA and one patient with ARCAPA (Anomalous origin of the Right coronary artery from the pulmonary artery) underwent surgical repair. We have reviewed the all medical records, electrocardiogram, chest X-ray and echocardiography retrospectively. Result: Three of the patients were boys and four were girls. The median age at the operation was 5.4 months (Range: 3$\∼$33 months). The average body weight of at the operation was 6.7 kg (Range: 3.7$\∼$11.3 kg). A mean follow up period was 18 months. Only 3 patients were initially diagnosed as ALCAPA. And 3 patients had moderate mitral regurgitation. Immediate coronary artery reimplantation on diagnosis with the aim of restoring a two-coronary system circulation was done. The average bypass time was 114$\pm$37 minutes, and the average aortic cross clamping time was 55$\pm$22 minutes. The average stay of intensive care unit was 5$\pm$3 days, the mean mechanical ventilator time was 38$\pm$45 hours and the hospital stay after operation was 12$\pm$5 days. There were significant improvements in electrocardiogram and chest X-ray of the all patients except one late death patient. The ventricular function showed almost normal recovery after operation; the EF (Ejection Fraction) increased from 41.2$\pm$ 10.3$\%$ to 60.5$\pm$ 15.8$\%$ within 1 month and to 59.8$\pm$13.9$\%$ within 1 year after operation, the SF (Shortening Fraction) increased from 23.6$\pm$4.7$\%$ to 38.6$\pm$8.4$\%$ within 1 month and to 37.4$\pm$7.9$\%$ within 1 year after operation, LVEDDI (Left Ventricular End-diastolic Dimension Index) decreased from 100.8$\pm$25.6 mm/$m^{2}$ to 90.3$\pm$ 19.2 mm/$m^{2}$ within f month and to 79.3$\pm$ 15.8 mm/$m^{2}$ within 1 year after operation. Concomitant mitral repair was done in two patients with anterior mitral leaflet prolapse. In every patient, mitral valve showed less than mild regurgitation during follow up. One late death occurred in which patient Dor procedure was applied 10 months after initial operation due to the dilated cardiomyopathy Conclusion: In the management of this rare and could be fatal Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA), early suspicion and correct diagnosis is of most important. But, after diagnosis, immediate restoration of 2 coronary systems could result in good outcome.