• Title/Summary/Keyword: Mechanical amplifier

Search Result 145, Processing Time 0.028 seconds

Analysis of Laser Weldment Distortion in the EDFA LD Pump Packaging (광신호 증폭기 EDFA LD 펌프 패키징 레이저 용접부 변형 해석)

  • Gang, Dae-Hyeon;Son, Gwang-Jae;Yang, Yeong-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.1
    • /
    • pp.139-146
    • /
    • 2001
  • This paper presents a study on heat transfer and residual distortion analysis of laser welded EDFA(Erbium Doped Fiber Amplifier) LD(Laser Diode) Pump using the finite element method. In the production process of LD Pump in light-wave communication system, ferrule and saddle are welded by Nd-YAG laser. These parts experience thermal and mechanical effect during heating and cooling cycle with the laser welding. Thus distortion happens in the laser-welded packaging, and it makes an error in detecting the light signal translate through optical fiber in LD Pump. The amount of final displacement produced by the laser welding is predicted using the finite element method. And the optimal shape of saddle is proposed with the results of numerical analyses to minimize the displacement.

  • PDF

A Study on Pressure Drop in Vortex Amplifier (와류증폭기에서의 압력강하에 관한 고찰)

  • Park, Jun Sang
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • An analysis on pressure drop in vortex amplifier has been performed. Based on theoretical approach with flow physics on well-known firm ground from previous studies, two dimensional flow model, which is very useful to calculate pressure drop of vortex amplifier, is proposed. Parametric studies on inlet and outlet boundary conditions also have been performed so that it found the most influential parameter is the inlet swirl velocity condition. Finally, a simple formulation is given to calculate total pressure drop.

The King Sejong′s String Clepsydra: (2) Bay and Night Time Announcing System (세종의 자격루 : (2)자격보시장치)

  • 남문현;서문호;한영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.702-706
    • /
    • 1996
  • The King Sejong's Striking water-clock was named for its distictive day and night time announcing system. Its time announcing system generates acoustic and visual signals for the twelve double hour, and combinations of two different acoustic signals for the five night watches, The mechanism of this signal generation system is triggered by a copper ball which is mechanically digitized time keeping signal, and is generated from the water clock. The time announcing system consisted four parts: 1) the mechanical amplifier which changes small copper to heavy steel ball, 2) day time announcing system, 3) night time announcing system, 4) sounding mechanism. The time announcing system of King Seong's Striking Clepsidra is remotely related to the Arabic clock system, however, it does have world-widely distictive mechanisms of its era, such as mechanical amplifier, self-weight rachet mechanism, and resetable mechanical computer etc.

  • PDF

3-DOF Parallel Micromanipulator : Design Consideration (3차원 평형 마이크로조정장치 : 설계 고려사항)

  • Lee, Jeong-Ick;Lee, Dong-Chan;Han, Chang-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.13-22
    • /
    • 2008
  • For the accuracy correction of the micro-positioning industrial robot, micro-manipulator has been devised. The compliant mechanisms using piezoelectric actuators is necessary geometrically and structurally to be developed by the optimization approaches. The overall geometric advantage as the mechanical efficiencies of the mechanism are considered as objective functions, which respectively art the ratio of output displacement to input force, and their constraints are the vertical notion of supporting leg and the structural strength of manipulation. In optimizing the compliant mechanical amplifier, the sequential linear programming and an optimality criteria method are used for the geometrical dimensions of compliant bridges and flexure hinges. This paper presents the integrated design process which not only can maximize the mechanism feasibilities but also can ensure the positioning accuracy and sufficient workspace. Experiment and simulation are presented for validating the design process through the comparisons of the kinematical and structural performances.

Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter (가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계)

  • Shim, Jae-Hyeok;Lee, Chang-Yeol;Kim, Seul-Gi;Kim, In-Dong;Moon, Won-Kyu;Lee, Jong-Hyeon;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.

Performance Evaluation of a Piezostack Single-stage Valve at High Temperatures (고온 환경에서의 압전작동기를 이용한 1단 밸브의 성능 평가)

  • Han, Chulhee;Kim, Wan Ho;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.168-174
    • /
    • 2017
  • In this work, a piezostack single-stage valve (PSSV) system is proposed and its control performance is experimentally evaluated at high temperature up to $150^{\circ}C$. In order to achieve this goal, a PSSV system is designed and operating principle and mechanical dimensions are discussed. A displacement amplifier and an adjust bolt are used to generate target displacement and to compensate thermal expansion. Then, an experimental apparatus is constructed to evaluate control performance of the PSSV system. The experimental apparatus consists of a heat chamber, a hydraulic circuit, a pneumatic circuit, pneumatic-hydraulic cylinders, thermal insulator, electronic devices, sensors, data acquisition (DAQ) board and a voltage amplifier. The flow rate and displacement control performance of the valve system are evaluated via experiment. The experimental results are evaluated and discussed at different temperatures and frequencies showing the controlled flow rate and spool displacement.

A Sensorless and Versatile Temperature-Control System for MEMS Microheaters (온도센서를 사용하지 않는 MEMS 마이크로히터 온도제어시스템)

  • Bae, Byung-Hoon;Yeon, Jung-Hoon;Flachsbart Bruce R.;Shannon Mark A.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.544-547
    • /
    • 2006
  • In this paper, we present a temperature-controlled system for MEMS electrical resistance heaters without a temperature sensor. To rapidly control the heater temperature, the microheater system developed consists of a power supply, power amplifier, digital ${\underline{P}}roportional-{\underline{I}}ntegral-{\underline{D}}ifferential$ (PID) controller, and a quarter bridge circuit with the microheater and three resistors are nominally balanced. The microheaters are calibrated inside a convection oven to obtain the temperature coefficient with a linear or quadratic fit. A voltage amplifier applies the supply voltage proportional to the control signal from the PID controller. Small changes in heater resistance generate a finite voltage across the quarter bridge circuit, which is fed back to the PID controller to compare with the set-point and to generate the control signal. Two MEMS microheaters are used for evaluating the developed control system - a NiCr serpentine microheater for a preconcentrator and a Nickel microheater for ${\underline{P}}olymerase\;{\underline{C}}hain\;{\underline{R}}eaction$ (PCR) chip.

Dynamic Modeling and Control of Directional Control Valve Using Piezostack Actuator (압전 작동기를 이용한 방향 제어 밸브의 동적 모델링 및 제어)

  • Jeon, Juncheol;Han, Young-Min;Nguyen, Quoc Hung;Han, Seung-Hun;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.331-336
    • /
    • 2012
  • This paper proposes a new type of high-frequency directional valve controlled by the piezostack actuator associated with displacement amplifier. As a first step, a dynamic model of directional valve which can operate at 200 Hz with a flow rate of 12 l/min is derived by considering pressure drop and flow force. As a second step, an appropriate piezostack is selected by considering actuation force as well as field-dependent displacement. Subsequently, in order to control spool displacement and flow rate a proportional-derivative (PD) controller is designed based on the $3^{rd}$-order valve system. Control performances such as sinusoidal trajectory tracking of the spool displacement in time domain are evaluated. In addition, the field-dependent flow rate is also presented to verify the required performance of the valve system.

  • PDF

Fabrication of a Breathing Assist Device for Saxophone Players with Breathing Problems

  • Kato, Tomonori;Ashikari, Tadataka;Matoba, Chikara;Mawatari, Asashi;Thumwarin, Pitak
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.72-76
    • /
    • 2021
  • The aim of this study was to establish a breathing assist system for saxophone players with breathing problems. Although the saxophone is a popular wind instrument with a reed in its mouthpiece, it can be difficult for people with breathing problems to play this instrument, as it requires adequate breath support for deep and even long breaths. To solve this problem, the authors propose a breathing assist device, which functions like a pneumatic master-slave amplifier, for saxophone players with breathing problems. First, the proposed device is fabricated. Second, the effectiveness of the breathing assist device as a master-slave amplifier is confirmed through experiments. Third, the dynamic characteristics of the device are tested up to 10 Hz, and they demonstrate that the device responds well for up to approximately 5 Hz.