• Title/Summary/Keyword: Mechanical Loss

Search Result 2,452, Processing Time 0.035 seconds

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.

Experimental Research on the Power Improvement by Increasing Intake pressure in a 1.4 L Turbocharged CNG Port Injection Spark Ignition Engine (1.4L 급 터보 CNG 엔진에서 흡기압력 상승에 따른 출력 증대 효과에 관한 연구)

  • Lee, Jeong-Woo;Park, Cheol-Woong;Bae, Jong-Won;Kim, Chang-Gi;Lee, Sun-Youp;Kim, Yong-Rae
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.90-96
    • /
    • 2019
  • Natural gas has been regarded as one of major alternative fuels, because of the increment of mining shale gas and supplying PNG(Pipeline Natural Gas) from Russia. Thus, it needs to broaden the usage of natural gas as the increasing its supplement. In this situation, application of natural gas on the transport area is a good suggestion to reduce exhaust emissions such as CO2(carbon dioxides) and soot from vehicles. For this reason, natural gas can be applied to SI(spark ignition) engines due to its anti-knocking and low auto-ignitibility characteristics. Recently, since turbocharged SI engine has been widely used, it needs to apply natural gas on the turbocharged SI engine. However, there is a major challenge for using natural gas on turbocharged SI engine, because it is hard to make natural gas direct injection in the cylinder, while gasoline is possible. As a result, there is a loss of fresh air when natural gas is injected by MPI (multi-point injection) method under the same intake pressure with gasoline-fueled condition. It brings the power reduction. Therefore, in this research, intake pressure was increased by controling the turbocharger system under natural gas-fueled condition to improve power output. The goal of improved power is the same level with that of gasoline-fueled condition under the maximum torque condition of each engine speed. As a result, the maximum power levels, which are the same with those of gasoline-fueled conditions, with improved brake thermal efficiency could be achieved for each engine speed (from 2,000 to 6,000 rpm) by increasing intake pressure 5-27 % compared to those of gasoline-fueled conditions.

Changes of Neutrophil Count in Peripheral Blood of the Neonate with Periventricular Leukomalacia (신생아 백질연화증 환아 말초혈의 중성구 변화)

  • Lee, Hwan Seok;Park, Kyung Pil;Kim, Heng Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.966-971
    • /
    • 2003
  • Purpose : It is now well established that infection and inflammation play an important role in the pathogenesis of ischemic brain damage. The loss of neutrophils from systemic circulation is an associated finding in injury mediated by granulocyte. Periventricular leukomalacia(PVL) caused by ischemia is the principal form of brain injury in premature infants. This study was conducted to evaluate whether the low neutrophil count is associated with periventricular leukomalacia(PVL) in premature infants. Methods : Retrospective review of medical records was undertaken. Subjects were premature infants with a birth weight of less than 1,500 gm, admitted to the Neonatal Intensive Care Unit of Kyungpook University Hospital. A complete blood count of peripheral blood was done within the 1st hour of life. Neutropenia was defined as absolute neutrophil count < $1,500/mm^3$, PVL as increased periventricular echodensities followed by cyst formation on ultrasonography or corresponding signs on brain MRI. Results : Thirteen infants out of a total population of 37 revealed neutropenia. Respiratory distress syndrome and requirement for respiratory support were not different between infants with neutropenia( neutropenia group) and infants without neutropenia(control group). Intraventricular hemorrhage (IVH) and grade 3 and 4 IVH were more frequent in neutropenia group(P<0.05). There was no statistically significant increase of PVL in neutropenia group. The neutrophil count was $18,760.0{\pm}10,266.1/mm^3$, $7,272.0{\pm}7,435.0/mm^3$ infants with PVL and $11,131.7{\pm}3,386.5/mm^3$, $2,407.5{\pm}1,933.1/mm^3$ in infants without PVL, respectively. The frequency of mechanical ventilation and artificial surfactant therapy was higher in infants with PVL compared with infants without PVL, but statistical analysis was not performed due to small number of subjects. Conclusion : A low number of neutrophils in the systemic circulation was not associated with an increased risk of PVL in premature infants.

Construction of cDNA Library and EST Analysis Related to Seed-hair Characteristics in Carrot (당근 종모 형질 관련 cDNA Library 작성 및 EST 분석)

  • Oh, Gyu-Dong;Shim, Eun-Jo;Jun, Sang-Jin;Park, Young-Doo
    • Horticultural Science & Technology
    • /
    • v.31 no.6
    • /
    • pp.782-789
    • /
    • 2013
  • Carrot (Daucus carota L. var. sativa) is one of the most widely used crops in the world and is nutritionally important crop. However, seed-hair which is generated in epidermal cell of seeds causes the difficulty of the seedling process, because of the seed germination and absorption inhibitions. For these reasons, carrot seeds are commercialized after mechanical hair removal process. However, in this process, various damage and seed loss occur and breeding of hairless-seed carrot cultivar is needed to overcome these various weaknesses and additional seed production costs. In this study, cDNA libraries using 2 combinations, which were composed of short-hair seed CT-ATR 615 OP 666-13 & long-hair seed CT-ATR 615 OP 671-9, and short-hair seed CT-SMR 616 OP 659-1 & long-hair seed CT-SMR 616 OP 677-14, were constructed and EST sequences of each individuals were analyzed to reveal carrot seed-hair characteristics. Firstly, analyzed EST sequences were classified into FunCat functional categories. As a result, significant differences have been identified in metabolism category, protein folding and stabilization, protein binding, C-compound binding category from both of two combinations. Secondly, several candidate EST sequences related to seed trichome differentiation and cellulose biosynthetic process were selected based on GO data of EST sequences. These differences based on FunCat categories and candidate EST obtained by GO data analysis are thought to be involved in the formation of carrot seed hair. Finally, 741 SSR sites and 33 SNP sites were identified from analyzed EST sequences of two combinations. Then we designed SNP and SSR primer sets to develop molecular markers. These molecular markers will be used for classification of carrot cultivars and study seed-hair characteristic.

Secondary Drying Effects on Garlic Quality after Low Temperature Storage (마늘의 저온저장 후 2차 건조가 품질에 미치는 영향)

  • Ning, Xiao Feng;Kang, Tae Hwan;Park, Jong Won;Han, Chung Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.9
    • /
    • pp.1452-1460
    • /
    • 2013
  • The purpose of this study was to investigate secondary drying effects on garlic quality, and to define the optimal secondary drying conditions for garlic preservation. The secondary drying tests used garlic that was naturally dried once and stored at low temperature. After secondary drying, the garlic was stored in a warehouse at room temperature. Tests were performed at different low-temperature storage periods (60, 105, 150, 195, and 240 days), secondary drying temperatures (35 and $40^{\circ}C$), drying times (1, 2, 3 days), and room temperature storage periods (15, 30, and 45 days). The results were compared with a non-secondary drying condition control. In general, the $40^{\circ}C$-2 days dry conditions showed the lowest weight-loss rate (5%) and rotting rate during room temperature storage. The sprouting rate increased by 20% during the initial 15 day-room temperature storage, along with a small increase after 30 days of room temperature storage. Increases in drying temperature and the period of secondary drying conditions caused a decrease in firmness. In addition, the sprouting rate was 10% higher, and rotting rate 5~10% higher, for the non-drying condition, compared to drying conditions. Based on our results, the $40^{\circ}C$-2 days drying condition is the optimal secondary drying condition for garlic storage.

Variation in Pod Shattering in a RIL Population and Selection for Pod Shattering Tolerance in Soybean [Glycine max (L.) Merr] (콩 RIL 집단의 내탈립성 변이 탐색 및 유망계통 선발)

  • Seo, Jeong Hyun;Kang, Beom Kyu;Kim, Hyun Tae;Kim, Hong Sik;Choi, Man Soo;Oh, Jae Hyeon;Shin, Sang Ouk;Baek, In Youl;Kwak, Do Yeon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.414-421
    • /
    • 2019
  • Pod shattering during the maturing stage causes a serious yield loss in soybean. It is the main limiting factor of soybean cultivation and mechanization. It is important to develop varieties suitable for mechanical harvesting and to develop energy-efficient agricultural machinery to save labor and costs. 'Daewonkong,' developed by the National Institute of Crop Science (NICS) in 1997, is an elite cultivar that occupies more than 80% of the soybean cultivation area in Korea because of its strong tolerance to pod shattering. The objectives of this study were to investigate the variation in pod shattering degree in a RIL population developed from a 'Daewonkong' parent and to select promising lines with pod shattering tolerance. 'Daewonkong' demonstrated a high level of tolerance to pod shattering compared to the 'Tawonkong' and 'Saeolkong' varieties, with no shattered pods after 72 hours of drying. Screening of pod shattering showed a clear distinction between the tolerant and susceptible varieties. Also, the distribution of shattering pod ratio in the two populations showed a similar pattern for three years. The promising lines with pod shattering tolerance included 27 lines in the 'Daewonkong'×'Tawonkong' population and 21 lines in the 'Daewonkong'×'Saeolkong' population. The promising lines are expected to be widely used as breeding parents for creating soybean cultivars with pod shattering tolerance.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Investigation of Viscoelastic Properties of EPDM/PP Thermoplastic Vulcanizates for Reducing Innerbelt Weatherstrip Squeak Noise of Electric Vehicles (전기차 인너벨트 웨더스트립용 EPDM/PP Thermoplastic Vulcanizates 재료설계인자에 따른 점탄성과 글라스 마찰 소음 상관관계 연구)

  • Cho, Seunghyun;Yoon, Bumyong;Lee, Sanghyun;Hong, Kyoung Min;Lee, Sang Hyun;Suhr, Jonghwan
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.192-198
    • /
    • 2021
  • Due to enormous market growing of electric vehicles without combustion engine, reducing unwanted BSR (buzz, squeak, and rattle) noise is highly demanded for vehicle quality and performance. Particularly, innerbelt weatherstrips which not only block wind noise, rain, and dust from outside, but also reduce noise and vibration of door glass and vehicle are required to exhibit high damping properties for improved BSR performance of the vehicle. Thermoplastic elastomers (TPEs), which can be recycled and have lighter weight than thermoset elastomers, are receiving much attention for weatherstrip material, but TPEs exhibit low material damping and compression set causing frictional noise and vibration between the door glass and the weatherstrip. In this study, high damping EPDM (ethylene-propylene-diene monomer)/PP (polypropylene) thermoplastic vulcanizates (TPV) were investigated by varying EPDM/PP ratio and ENB (ethylidene norbornene) fraction in EPDM. Viscoelastic properties of TPV materials were characterized by assuming that the material damping is directly related to the viscoelasticity. The optimum material damping factor (tanδ peak 0.611) was achieved with low PP ratio (14 wt%) and high ENB fraction (8.9 wt%), which was increased by 140% compared to the reference (tanδ 0.254). The improved damping is believed due to high fraction of flexible EPDM chains and higher interfacial slippage area of EPDM particles generated by increasing ENB fraction in EPDM. The stick-slip test was conducted to characterize frictional noise and vibration of the TPV weatherstrip. With improved TPV material damping, the acceleration peak of frictional vibration decreased by about 57.9%. This finding can not only improve BSR performance of electric vehicles by designing material damping of weatherstrips but also contribute to various structural applications such as urban air mobility or aircrafts, which require lightweight and high damping properties.

Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position (구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구)

  • Soo-Young Hong;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.101-112
    • /
    • 2023
  • Purpose. This retrospective study was to investigate the survival and complication rates of posterior single implant according to the implant diameters, lengths and position. Materials and methods. Patients who had been restored single implant prosthesis in the posterior area by the three prosthodontists in the department of prosthodontics, Daejeon dental hospital of Wonkwang university, in the period from February 2014 to May 2018 were selected for the study. A total of 505 patients with 697 implants were observed. The survival and complications of implants were investigated using electronic medical records and radiographs. Fixture diameters, lengths, position, patient's sex and age were assessed as possible factor affecting the survival and complications of implants. Results. 3-year cumulative survival rates of posterior single implants were 98.5% and 5-year cumulative survival rates were 94.4%. 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm (97.0%) than implants with diameter ≤ 4.0 mm (89.5%), and in females (98.8%) than males (92.4%). There were statistically significant differences (P < .05). The mechanical complication rate was 20.1% and the biological complication rate was 4.7%. Complications occurred in order of abutment screw loosening (7.5%), decementation (6.3%), proximal contact loss (3.7%) and so on. Abutment screw loosening occurred more frequently in the lower molar region (10.5%), in males (9.5%) than females (5.1%), and in patients aged < 65 years (9.4%) than patients aged ≥ 65 years (5.1%). There were statistically significant differences (P < .05). Conclusion. The 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm than implants with diameter ≤ 4.0 mm and in females than males. Abutment screw loosening which was the most commonly occurring complication occurred more frequently in the lower molar region, in males than females, and in patients aged < 65 years than patients aged ≥ 65 years. There were statistically significant differences.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.