• Title/Summary/Keyword: Mechanical Loads

Search Result 1,767, Processing Time 0.025 seconds

Structural Analysis of a Suction Pad for a Removable Bike Carrier using Computational and Experimental Methods (탈착식 자전거 캐리어용 흡착 패드의 실험 및 전산적 방법을 활용한 구조해석)

  • Suh, Yeong Sung;Lim, Geun Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.622-628
    • /
    • 2016
  • As the suction pad-supporting bike carrier attached to a car may be subject to an excessive dynamic load due to random vibrations and centrifugal forces during driving, its structural safety is of great concern. To examine this, the finite-element method with a fluid-structure interaction should be used because the pressure on the pad bottom is changed in real time according to the fluctuations of the force or the moment applied on the pad. This method, however, has high computing costs in terms of modeling efforts and software expense. Moreover, the accuracy of computation is not easily guaranteed. Therefore, a new method combining the experiment and computation is proposed in this paper: the bottom pressure and contact area of the pad under varying loads was measured in real time and the acquired data are then used in the nonlinear elastic finite-element calculations. The computational and experimental results obtained with the product under development showed that the safety margin of the pad under the axial loading is relatively sufficient, whereas with an excessive rotational loading, the pad is vulnerable to separation or a local surface damage; hence, the safety margin may not be secured. The predicted contact behavior under the variation of the magnitude and type of the loading were in good agreement with the one from the experiment. The proposed analysis method in this study could be used in the design of similar vacuum pad systems.

Analytical and experimental study on the quality improvement of 2 cavity injection-molded LCD frame (2 캐비티 LCD 사출품의 품질향상에 관한 해석 및 실험적 연구)

  • Son, Jae-Hwan;Jang, Eun-Sil;Han, Chang-Woo;Son, Jae-Yong;Lee, Young-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3815-3821
    • /
    • 2012
  • The LCD frame is an important part which supports the BLU of medium/large sized TFT-LCD. To produce it efficiently, it is necessary to achieve the molding process improvement from 1 cavity to 2 cavity system. Because 2 cavity mold is compact and its hot-runner zone is broadened, it is difficult to control the temperature on the mold. In this study, injection molding analysis on the frame in 2 cavity process with FEA(Finite Element Analysis) software is carried out to estimate its quality. The calculated injection molding pressures and maximum deflection in 1 and 2 cavity processes are 41.13 MPa and 1.62 mm, 40.49 MPa and 1.66 mm respectively. The measured maximum flexure load and surface roughness of the left and right frame of 2 cavities are 209 N and 0.08 ${\mu}m$, 193 N and 0.10 ${\mu}m$ while those in 1 cavity are 140 N and 0.13 ${\mu}m$. Thermal image shows that the maximum standard deviation of the temperature on left and right side of 2 cavity mold is $1.23^{\circ}C$. The simulation and measurement results show that the quality of the frame in 2 cavity injection molding process as a whole is not worse than that of 1 cavity system. But maximum flexure loads of the frame in 2 cavity process are far greater than that in 1 cavity process.

Design Improvements for Preventing Crack of Equipment Mounting Structure in Rotary Wing Aircraft (회전익 항공기의 장비 장착 지지 구조물의 균열 방지를 위한 설계 개선)

  • Bang, Daehan;Lee, Sook;Lee, Sanghoon;Choi, Sangmin
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.28-35
    • /
    • 2020
  • This paper presents the design improvements made for the crack which is in the mounting structure of the mechanical structure of rotary wing aircraft. The doubler added to the mounting structure of rotary wing aircraft was designed and manufactured based on the load at the development stage, and a crack was found in the surface of doubler at a certain point during the operation of the aircraft. To identify the cause of the crack, the initial deformation of the structure, which may occur as a result of fastening condition, was considered and the dynamic analysis of the natural frequency of the structure comparing to the blade passing frequency of the aircraft were additionally reviewed. As a result of this study, a shim was added to remove the physical gap of the fastening area, and a doubler with thickened reinforcement was installed. The increase of structural strength is shown by reviewing the results of dynamic analysis for the structural verification of the improved design, and the fatigue evaluation complied to the requirement of the aircraft lifetime.

A study on the arrangement of integrated power system for warship (함정의 통합 전력시스템 구성에 관한 연구)

  • Baek, Hyun-Min;Jung, Kyun-Sik;Lee, Myung-Ho;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1070-1074
    • /
    • 2014
  • According to IEEE 1662(2009), IPS is a power system where all prime movers produce electrical power that is shared among propulsion, mission, and ship service loads. Discriminating attributes of integrated power systems are flexibility of movers' arrangements, mechanical decoupling between prime movers and propulsors, an increased level of energy conversion and transmission redundancy, and flexibility of redistributing available electrical power for future electronic weapons. IPS could have various steps of power that can be produced at optimal load of movers. In this study, an evaluation method for optimal arrangement of movers was investigated when an IPS warship is projected. The two factors are utilized for the quantitative analysis which are the weight of system as the fighting power and the fuel consumption per year as the economic feasibility. And also the ways for arrangement of system were studied according to existence of small diesel generator. The evaluation method that decides the optimization level is based on the DEA(Data Envelopment Analysis)

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

Sleep-Related Respiratory Disturbances (수면과 관련된 호흡장애)

  • Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.2 no.1
    • /
    • pp.55-64
    • /
    • 1995
  • During sleep, relatively major respiratory physiological changes occur in healthy subjects. The contributions and interactions of voluntary and metabolic breathing control systems during waking and sleep are quite different Alterations of ventilatory control occur in chemosensitivity, response to mechanical loads, and stability of ventilation. The activities of intercostal muscles and muscles involved in regulating upper airway size are decreased during sleep. These respiratory physiological changes during sleep compromise the nocturnal ventilatory function, and sleep is an important physiological cause of the nocturnal alveolar hypoventilation. There are several causes of chronic alveolar hypoventilation including cardiopulmonary, neuromuscular diseases. Obstructive sleep apnea syndrome (OSAS) is an important cause of nocturnal hypoventilation and hypoxia. Coexistent cardiopulmonary or neuromuscular disease in patients with OSAS contributes to the development of diurnal alveolar hypoventilation, diurnal hypoxia and hypercapnia. The existing data indicates that nocturnal recurrent hypoxia and fragmentation of sleep in patients with OSAS contributes to the development of systemic hypertension and cardiac bradytachyarrhythmia, and diurnal pulmonary hypertension and cor pulmonale in patients with OSAS is usually present in patients with coexisting cardiac or pulmonary disease. Recent studies reported that untreated patients with OSAS had high long-term mortality rates, cardiovascular complications of OSAS had a major effect on mortality, and effective management of OSAS significantly decreased mortality.

  • PDF

A Study on the Development of Plastic Floater for Solar Power Plant on a Body of Water (수상 태양광 발전을 위한 플라스틱 부유체 개발에 관한 연구)

  • Jeong, Kwang-Soo;Jung, In Jun;Shin, Dong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.283-290
    • /
    • 2020
  • In this study, a floater was developed for a frame-type solar power plant. The floater supports the frame and the solar panels. A finite element analysis was performed to design its shape and thickness, and the floater was manufactured by a rotational molding method using linear low-density polyethylene. It was found that the floater did not cause collapse and it maintained its stiffness even at 4 times the maximum load of 322.7 kgf. To perform a long-term compression test, a weight-type load application device that uses gravity was designed and manufactured. The amount of compressive deformation was measured for 7 days, and a long-term deformation equation was obtained. Even under small loads, continuous deformation was observed. However, the 10-year deformation amount for a constant load of 100 kgf was predicted to be small at about 4.64 mm. As a result, it was found that the developed floater could be used in a solar power plant on a body of water.

Development of Integrated Model of Boiler and Its Supporting Steel Structure of Coal-Fired Power Plant for Finite Element Analysis (유한요소해석을 위한 석탄화력발전소의 보일러와 지지 철골의 통합모델 개발)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.9-19
    • /
    • 2020
  • An integrated finite element model composed of a boiler and its supporting steel structure for a 375-MW coal-fired power plant was developed. This study used the developed model for seismic analysis using SAP2000 software. For the complex superheaters, reheaters, economizers, and membrane walls of the boiler, which consisted of numerous tubes, a method of modeling them by the equivalent elements in the viewpoint of stiffness and/or inertia was proposed. In addition, a method of modeling for the connection between the boiler and steel structure was proposed. Many hangers that connect the boiler to the girders of a steel structure were transformed into equivalent hangers by decreasing the number. The displacements of the boiler stoppers on the buckstay and the posts of the steel structure were coupled by considering their interface condition. Static analysis under the self-loading condition for the developed integrated model was implemented, and the results of deformation indicated that the behavior of the steel members and the major components of the boiler were appropriate. In conclusion, the integrated model developed in this study can be used to evaluate the safety of the boiler and steel structure under seismic loads.

A Study on Characteristics of an Integrated Urea-SCR Catalytic Filter System for Simultaneous Reduction of Soot and NOX Emissions in ECU Common-rail Diesel Engines (ECU 커먼레일 디젤기관에 있어서 매연 및 NOX 배출물 동시 저감용 일체형 요소-SCR 촉매필터 시스템의 특성에 관한 연구)

  • Bae, Myung-Whan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.111-120
    • /
    • 2014
  • The aim of this study is to develop an integrated urea-SCR catalytic filter system for reducing soot and $NO_X$ emissions simultaneously in diesel engines. In this study, the characteristics of exhaust emissions relative to reactive activation temperature under four kinds of engine loads are experimentally investigated by using a four-cycle, four-cylinder, direct injection type, water-cooled turbo intercooler ECU common-rail diesel engine with the integrated urea-SCR $MnO_2-V_2O_5-WO_3/TiO_2/SiC$ catalytic filter system operating at three kinds of engine speeds. The urea-SCR reactor is used to reduce $NO_X$ emissions, and the catalytic filter system is used to reduce soot emissions. The reactive activation temperature is very important for reacting a reducing agent with exhaust emissions. The reactive activation temperatures in this experiment is applied to 523, 573 and 623 K. The fuel is sprayed by the pilot and main injections at the variable injection timing between BTDC $15^{\circ}$ and ATDC $1^{\circ}$ according to experimental conditions. It is found that the $NO_X$ conversion rate is the highest as 83.9% at the reactive activation temperature of 523 K in all experimental conditions of engine speed and load, and the soot emissions shown by the average reduction rate of approximately 93.3% are almost decreased below 0.6% in all experimental conditions regardless of reactive activation temperatures. Also, the THC and CO emissions by oxidation reaction of Mn, V and Ti are shown in the average reduction rates of 70.3% and 38% regardless of all experimental conditions.

A Study on Development of ECS for Severly Handicaped (중증 장애인을 위한 생활환경 제어장치개발에 관한 연구)

  • 임동철;이행세;홍석교;이일영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.427-434
    • /
    • 2003
  • In this paper, we present a speech-based Environmental Control System(ECS) and its application. In the concrete, an ECS using the speech recognition and an portable wheelchair lift control system with the speech synthesis are developed through the simulation and the embodiment. The developed system apply to quadriplegic man and we evaluate the result of physical effect and of mental effect. Speech recognition system is constructed by real time modules using HMM model. For the clinical application of the device, we investigate the result applied to 54-years old quadriplegic man during a week through the questionnaires of Beck Depression Inventory and of Activity Pattern Indicator. Also the motor drive control system of potable wheelchair lift is implemented and the mechanical durability is tested by structural analysis. Speech recognition rate results in over 95% through the experiment. The result of the questionnaires shows higher satisfaction and lower nursing loads. In addition, the depression tendency of the subject were decreased. The potable wheelchair lift shows good fatigue life-cycle as the material supporting the upper wheelchair and shows the centroid mobility of safety. In this paper we present an example of ECS which consists of real-time speech recognition system and potable wheelchair lift. Also the experiments shows needs of the ECS for korean environments. This study will be the base of a commercial use.