• Title/Summary/Keyword: Meatus

Search Result 47, Processing Time 0.026 seconds

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

Reconstruction of Congenital Absence of Vagina using Vulvoperineal Fasciocutaneous Flap: A Case Report (외음회음 근막피부피판을 이용한 선천성 질결여증의 재건례)

  • Kim, Mi-Sun;Kim, Chul-Han;Lee, Yong-Sek;Kang, Sang-Gue;Tark, Min-Sung
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.831-834
    • /
    • 2010
  • Purpose: Congenital absence of the vagina is a rare case. It occurs as a result of Mullerian duct aplasia or complete androgen insensitivity syndrome. The reconstructive modality includes skin graft, use of intestine and various methods of flap. We report a patient who underwent vulvoperineal fasciocutaneous flap to reconstruct congenital absence of the vagina, while the external genitalia and ovaries are normal. Methods: A 26-year-old woman presented with vaginal agenesis. Under general anesthesia, a U-shaped incision was made between the urethral meatus and the anus. The new vaginal pocket was created up to the level of the peritoneal reflection between the urinary structures and the rectum. Next, the vulvoperineal fasciocutaneous flaps were designed in a rectangular fashion. Flap elevation was begun at the lateral margin which the adductor longus fascia was incised and elevated, and the superficial perineal neurovascular pedicle was invested by the fascial layer. The medial border was then elevated. A subcutaneous tunnel was created beneath the inferior of the labia to rotate the flaps. The left vulvoperineal flap was rotated counterclockwise and the right was rotated clockwise. The neovaginal pouch was formed by approximating the medial and lateral borders. The tubed neovagina was then transposed into the cavity. Results: In 3 weeks, the vaginal canal remained supple After 6 weeks, the physical examination showed normalappearing labia majora and perineum with an adequate vaginal depth. A year after the operation, the patient had a 7 cm vagina of sufficient width with no evidence of contractures nor fibrous scar formation. The patient was sexually active without difficulty. Conclusion: Although many methods were described for reconstruction of vaginal absence, there is not a method yet to be approved as a perfect solution. We used the vulvoperineal fasciocutaneous flap to reconstruct a neovagina. This method had a following merits: a single-stage procedure, excellent flap reliability, the potential for normal function, minimal donor site morbidity and no need for subsequent dilatation, stents, or obturators. We thought that this operation has a good anatomic and functional results for reconstruction of the vagina.

Retrospective Analysis of Cerebellopontine Angle Meningiomas (소뇌교각부 수막종의 후향적 분석)

  • Kim, Sang Hyo;Kim, Suk Chul;Jung, Shin;Kang, Sam Suk;Kim, Tae Sun;Lee, Jung Kil;Kim, Jae Hyoo;Kim, Soo Han;Lee, Je Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.30-36
    • /
    • 2001
  • Objective : To investigate the postoperative result and prognostic factors in cerebellopontine meningioma. Materials & Methods : During the years 1990 through 1999, a retrospective study of 17 cerebellopontine angle meningiomas was performed. The retromastoid approach was used in all cases : 14 tumors were excised totally and 3 tumors subtotally. Results : Fourteen patents were females with a median age of 58.7 years. The most common presenting complaints were 8th cranial nerve dysfunction and headache. Most of the tumors were large(>4cm) and extended into the tentorial regions. Histological examination revealed benign meningiomas in 16 patients and atypical in one patient. Tumors were located posterior to the internal auditory meatus in 11 cases and anterior in three cases with three cases of en-plaque type. Two of three patients whose tumors were subtotally excised received radiation therapy. Tumor has recurred in one patient. Postoperative result was good in 16 cases with one mortality case. Conclusion : This results suggest that site of 7th-8th cranial nerves complex, en-plaque type meningioma, and petroclival meningioma extended into the clivus were significant prognostic factors. Postoperative radiation therapy is recommended for cases of subtotal resection.

  • PDF

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Efficacy of Endoscopic Electrocauterization for Recurrent Posterior Epistaxis (반복되는 후방 비출혈에서 내시경 지혈술의 효과)

  • Lee, Jung Joo;Lee, Eunkyu;Ryu, Gwanghui;Seo, Min Young;Hong, Sang Duk;Kim, Hyo Yeol;Dhong, Hun-Jong;Chung, Seung-Kyu
    • Journal of Rhinology
    • /
    • v.25 no.2
    • /
    • pp.75-79
    • /
    • 2018
  • Background and Objectives: To investigate the common site of recurrent epistaxis after initial intervention such as packing and cauterization had failed and to evaluate the efficacy of surgical endoscopic electrocautery. Subjects and Method: Retrospective review of 47 patients with recurrent and uncontrolled idiopathic epistaxis between October 1995 and March 2016. All patients underwent endoscopic examination in the operating room after hospitalization. We performed electrocautery when a bleeding site was found. Results: The most common sites of bleeding were the inferior meatus (28%), sphenoethmoid recess (23%), superior septum around the olfactory cleft (13%), and the posterior end of the middle turbinate (15%). There was no serious complication during the one week after surgery. In 46 (98%) patients, refractory epistaxis was successfully controlled. One patient had recurrent epistaxis after electrocautery and underwent endoscopic sphenopalatine artery ligation. Conclusion: In patients with refractory idiopathic epistaxis after failure of first-line treatment, endoscopic examination through a surgical approach and electrocautery for suspected bleeding are effective.

Laryngeal height and voice characteristics in children with autism spectrum disorders (자폐스펙트럼장애 아동의 후두 높이 및 음성 특성)

  • Lee, Jung-Hun;Kim, Go-Woon;Kim, Seong-Tae
    • Phonetics and Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.91-101
    • /
    • 2021
  • The purpose of this study was to investigate laryngeal characteristics in children with autism spectrum disorders (ASD). A total of 50 children participated, including eight children aged 2 to 4 years old diagnosed with ASD and 42 normal controls at the same age. All children recorded X-ray images of the midsagittal plane of the cervical spine and larynx, and compared the laryngeal positions of ASD and control. In addition, samples of children with vowel prolongation were collected and analyzed for acoustic parameters. X-rays showed that the height of the hyoid bone in the normal group was the lowest at 3 years of age, and ascended at 4 years of age. Nevertheless, the distance from the external acoustic meatus to the hyoid bone was longest at age 4. 4-year-olds with explosive language development showed laryngeal height elevation and anteriorization. In contrast, the hyoid height of the ASD group of all ages was lower than that of the control group, and there was no difference in the hyoid position between the ages. As a result of acoustic evaluation, PFR, vFo, and vAm were significantly higher ASD than control. Low laryngeal height of ASD children may be associated with delayed language development. PFR, vFo, and vAm seem to be voice markers showing the difference between normal and ASD children.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).