• Title/Summary/Keyword: Measuring head

Search Result 411, Processing Time 0.024 seconds

Effects of the Method of Changing Compression Ratio on Engine Performance in an SI Engine (가솔린 엔진에서 압축비 변경 방법이 성능에 미치는 영향)

  • 이원근;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.27-33
    • /
    • 2001
  • In this study, it is observed that the distribution of combustion chamber volume affects the volumetric efficiency. The distribution ratio was adjusted by controlling combustion chamber volume of head and piston bowl one. Four cases were investigated, which are the combination of different distribution ratios and different compression ratios (9.8-10.0). A commercial SOHC 3-valve engine was modified by cutting the bottom face of the head and/or replacing the piston by the one that has different volume. The result shows that the less the head side volume, the more volumetric efficiency is achieved under the same compression ratio. It is also observed that increasing volumetric efficiency results in early knock occurrence due to increased "real" compression ratio. To consider reliability in estimating the volumetric efficiency, we examined the sensitivity of the AFR equation to possible errors in emission measurements. It is shown that the volumetric efficiency, which is calculated by measuring AFR and fuel consumption, can be controlled in 1% error. 1% error.

  • PDF

Characterizing Distribution the Head Width in a Holometabolous Insect Larvae (완전변태류 유충의 두폭분포 추정방법)

  • Ryoo Mun Il
    • Korean journal of applied entomology
    • /
    • v.22 no.1 s.54
    • /
    • pp.45-47
    • /
    • 1983
  • The d/w ratio, initially proposed for measuring resource utilization of an organism, was introduced for an objective description of the larval head width distribution in a holometabolous insect. The statistical method was successfully applicated in the case of Sitophilus oryzae, and, therefore, could be also used for characterizing the larval head width distribution of other insects.

  • PDF

The Tectonic Characteristics of ′KAN′ in the head residence of Uisong Kims (의성 김씨종택에 있어서 간의 건축적 특성)

  • 장선주;이강훈
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.11-19
    • /
    • 2004
  • The purpose of this study is to explain the tectonic characteristics of 'Kan' which is an unit of composition in the head residence of Uisong Kims. Here, the 'Kan' is assumed as a conceptual framework to organize a house and also a maneuvering tool to control the spatial order with relationship between the whole and the part. Not limited to the simple conceptual aspects, but the interrelated elements such as the site conditions, modules, functions, structure and aesthetic factors. Through the process of the study, the role of 'Kan' is proved to be a tectonic tool for self-regulating architectural order by relation matrix of elements. 'Kan' is not only a fixed measuring tool for functions and material of a house but also a flexible device to control the building composition. 'Kan' is certainly a relative subject for measurement of form, space and aesthetic quality.

Ballistocardiographical Heart Rate Measurement Using Head Mounted 6-axis Accelerometer (머리 착용형 6축 가속도계를 사용한 심탄도 심박수 측정)

  • Jinman Kim;Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.33-37
    • /
    • 2024
  • Recently, wearable virtual reality devices are widely used. These instruments include a 3-axis accelerometer. User's heart rate information in virtual reality contents can be useful for measuring user experience. In this paper, we propose a method to measure the heart rate through a 3-axis accelerometer based on the principle of ballistocardiography without additional sensors. The angular velocity was successively measured in a time series by the 3-axis accelerometer mounted to the head. The frequency of the maximum magnitude is determined as the heart rate through frequency transform and band pass filtering of the time series signal. For verification, the heart rate calculated from photoplethysmography sensors acquired at the same time was compared as ground-truth. In the virtual reality, the user's heart rate information can be extracted without additional heart rate sensor, and the emotional state and fatigue can be measured.

  • PDF

The effect of applying a head-weight device on cervical angle and pain of neck muscles

  • Kim, Jin-Hong;Kim, Jong-Gun;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • Objective: The purpose of this study was to measure the change in pain threshold of levator scapular muscle, carniovertebral angle, and head position angle when applying a head-weight device on healthy adult. Design: Cross-sectional study. Methods: This study was conducted with 21 healthy adult male and female who voluntarily agreed to participate in this study after being informed of the purpose and method of this study. After measuring the cervical angle and pain threshold of levator scapular muscle, subject was instructed to walk for 5 minutes on a treadmill at a speed of less than 5 km/h while wearing after wearing head-weight device of 0.5 kg. Then, cervical spine angle and pain threshold of levator scapula muscle were re-measured. Measurement of cervical spine angle was conducted with photo by using the Bluebeam Revu software and the pain pressure thresholds (PPTs) were measured using an electronic algometer over potential trigger points on the body. Results: The results cervical angle showed a significant change, from $49.62^{\circ}$ to $52.10^{\circ}$ (p<0.05). PPT showed a significant change, from 30.71 to 36.89 (p<0.05). Conclusions: These findings suggest that applying head-weight device has a positive influence on increasing cervical angle and reducing pain when applied as a therapeutic intervention method of forward head posture.

A Case of Oncocytic Lipoadenoma Arising in the Submandibular Gland (악하선에 발생한 호산성 지방선종 1례)

  • Lee, Bum Sang;Lee, Jong Kyu;Jang, Soo Kyung;Seo, Kang Hyun;Kim, Jin Hwan;Bang, Heejin;Lee, Dong Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.35 no.2
    • /
    • pp.35-38
    • /
    • 2019
  • Oncocytic lipoadenoma is a rare salivary gland tumor composed of adipose tissue and oncocytic epithelial cells in varied proportions. We report a case of an oncocytic lipoadenoma of the submandibular gland, which presented as a submandibular gland mass. The patient was a 65-year-old woman with a right submandibular mass measuring 2 × 2 × 1.6 cm. As a sonographic evaluation and computed tomograph scan gave us the impression of benign submandibular gland tumor such as pleomorphic adenoma, we resected the right side submandibular gland. Grossly, the tumor was well circumscribed with yellow to brown cut surface. Microscopically, the tumor was surrounded by a thin, fibrous capsule and composed of oncocytic epithelial cells admixed with mature adipose tissue. Final diagnosis was an oncocytic lipoadenoma. We discussed here radiologic and pathologic finding of this rare salivary gland tumor.

Electro-magnetic measuring system for head rotations (전자기학적 방법을 이용한 머리운동 측정 시스템)

  • 남문현;김정현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.652-657
    • /
    • 1986
  • 본 연구는 시야나 머리운동을 구속하지 않고 수평 및 수직 머리운동을 측정하여 처리하는 방법에 관한 것이다. 이를 위해 Helmholtz 코일을 적절히 구성하여 균일 자계를 발생시키고 탐지 코일을 이용하여 머리운동의 동적 특성을 검출하고, 검출된 신호는 신호처리 장치를 구성하여 처리하는 방법을 개발하고 다른 연구결과와 비료 고찰하였다.

  • PDF

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

Development of a system for measuring inside & outside diameters of automobile hub (자동차 허브 내.외경 측정 시스템 개발)

  • 윤규택;이동주;최만용;박혜원;박정학]
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.363-368
    • /
    • 2002
  • An automobile hub is composed of a hollow cylindrical part with inner and outer diameters. These hub diameters must be precise, as any irregularities in them (diameters) can influence/degrade the motion of an automobile with this problem. Highly accurate and reliable hub inner and outer diameters measurement systems are therefore required for inspection of the diameters. In this research, an automobile hub inner and outer diameters measurement system has been developed and tested. The system consists of measuring heads with LVDT sensors, and associated software for automatic measurement and calibration of the diameters and the sensors respectively. The system has been evaluated in comparison with an existing measurement system, and the following outcomes have been achieved; .Improved and guaranteed quality and reliability .Increased productivity and cost reduction. These results prove the system developed in this research to be suitable for automobile hub inspection.

  • PDF

Survey of Eye Movement Measuring Techniques (눈움직임 측정방법에 대한 연구)

  • 김유창
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.59-66
    • /
    • 1997
  • When using hazard machines such as automobiles, operators receive information through eye. The operater must process the information quickly and properly in order to perform the operation efficiently and safely. Therefore, several techniques to measure the eye movements have been developed. The choice of an optimum method for a situation depend on the type of data needed, the necessity of knowing the position of the observer's head, and the tradeoffs of precesion versus comfort. The goal of this study is to review the present status of the measure and the eye movement measuring techniques, to investigate the development trend, and to show that some measure and eye movement measuring techniques are adquate for some task.

  • PDF