• Title/Summary/Keyword: Measuring device

Search Result 1,514, Processing Time 0.031 seconds

Study on Temperature and Vibration of BLDC Motor (BLDC 모터의 온도 및 진동 특성 연구)

  • Ye, Jung-Woo;Son, Mun-Gyu;Choe, Myoung-Hwan;Kim, Dae-Hwa;Cho, Yeon-Su;Lee, Hyun-Seok;Shim, Jae-Sool
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.43-51
    • /
    • 2014
  • In this paper, transient temperature and vibration characteristics of a brushless DC (BLD(c) motor are studied for external load (165W~495W) and rotational speed (2000 rpm~4000 rpm). For experiment, a simple measurement system is developed to allow a change in load and speed for measuring transient temperature and vibration simultaneously. Temperature and vibration were also measured under the conditions of natural convection and forced convection. Vibrations in the directions of x-axis (#Ch1), y -axis (#Ch2) and z -axis (#Ch3) were obtained by three accelerometers and temperature was obtained by a thermo-couple with respect to time until the motor is steady. Experimental results show that the amplitude of vibration is higher in the order of z-axis (#Ch3), x -axis (#Ch1) and y-axis (#Ch2) and the amplitude of vibration at the forced convection conditions is 10.6% to 17.8% lower than that of vibration at the natural convection. However, the ratio of the vibration value is similar on average regardless of external convection condition.

CdSe Nanocrystal Quantum Dots Based Hybrid Heterojunction Solar Cell

  • Jeong, So-Myung;Eom, S.;Park, H.;Lee, Soo-Hyoung;Han, Chang-Soo;Jeong, So-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.93-93
    • /
    • 2010
  • Semiconductor nanocrystal quantum dots (NQDs) have recently attracted considerable interest for use in photovoltaics. Band gaps of NQDs can be tuned over a considerable range by varying the particle size thereby allowing enhance absorption of solar spectrum. NQDs, synthesized using colloidal routes, are solution processable and promise for a large-area fabrication. Recent advancements in multiple-exciton generation in NQD solutions have afforded possible efficiency improvements. Various architectures have attempted to utilize the NQDs in photovoltaics, such as NQD-sensitized solar cell, NQD-bulk-heterojuction solar cell and etc. Here we have fabricated CdSe NQDs with the band gap of 1.8 eV to 2.1 eV on thin-layers of p-type organic crystallites (1.61 eV) to realize a donor-acceptor type heterojuction solar cell. Simple structure as it was, we could control the interface of electrode-p-layer, and n-p-layer and monitor the following efficiency changes. Specifically, surface molecules adsorbed on the NQDs were critical to enhance the carrier transfer among the n-layer where we could verify by measuring the photo-response from the NQD layers only. Further modifying the annealing temperature after the deposition of NQDs on p-layers allowed higher conversion efficiencies in the device.

  • PDF

Boron doping with fiber laser and lamp furnace heat treatment for p-a-Si:H layer for n-type solar cells

  • Kim, S.C.;Yoon, K.C.;Yi, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.322-322
    • /
    • 2010
  • For boron doping on n-type silicon wafer, around $1,000^{\circ}C$ doping temperature is required, because of the relatively low solubility of boron in a crystalline silicon comparing to the phosphorus case. Boron doping by fiber laser annealing and lamp furnace heat treatment were carried out for the uniformly deposited p-a-Si:H layer. Since the uniformly deposited p-a-Si:H layer by cluster is highly needed to be doped with high temperature heat treatment. Amorphous silicon layer absorption range for fiber laser did not match well to be directly annealed. To improve the annealing effect, we introduce additional lamp furnace heat treatment. For p-a-Si:H layer with the ratio of $SiH_4:B_2H_6:H_2$=30:30:120, at $200^{\circ}C$, 50 W power, 0.2 Torr for 30 min. $20\;mm\;{\times}\;20\;mm$ size fiber laser cut wafers were activated by Q-switched fiber laser (1,064 nm) with different sets of power levels and periods, and for the lamp furnace annealing, $980^{\circ}C$ for 30 min heat treatment were implemented. To make the sheet resistance expectable and uniform as important processes for the $p^+$ layer on a polished n-type silicon wafer of (100) plane, the Q-switched fiber laser used. In consequence of comparing the results of lifetime measurement and sheet resistance relation, the fiber laser treatment showed the trade-offs between the lifetime and the sheet resistance as $100\;{\omega}/sq.$ and $11.8\;{\mu}s$ vs. $17\;{\omega}/sq.$ and $8.2\;{\mu}s$. Diode level device was made to confirm the electrical properties of these experimental results by measuring C-V(-F), I-V(-T) characteristics. Uniform and expectable boron heavy doped layers by fiber laser and lamp furnace are not only basic and essential conditions for the n-type crystalline silicon solar cell fabrication processes, but also the controllable doping concentration and depth can be established according to the deposition conditions of layers.

  • PDF

An Experimental Study on the Evaluaiton of Elastic-Plastic Fracture Toughness under Mixed Mode I-II-III Loading Using the Optical PSD (PSD를 이용한 혼합모드 하중하에서 탄소성 파괴인성평가에 관한 실험적인 연구)

  • Kim, Hei-Song;Lee, Choon-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1263-1274
    • /
    • 1996
  • In this paper, as elastic-plastic fracture toughness test under mixed mode loading was proposed using a single edge-cracked specimen subjected to bending moment(M), shearing force(F), and twisting moment(T). The J-integral of a crack in the specimen is expressed in the form J=$J_I$+ $J_II$$J_III$, where $J_I$, $J_II$ and $J_III$ are the components of mode I, mode II and mode III deformation, respectively. $J_I$, $J_II$ and $J_III$ can be estimated from M-$\theta$ ($\theta$;crack opening angle), F-U(U; crack shear displacement) and T-$\alpha$ ($\alpha$;crack twisting angle). In order to obtain the the M<-TEX>$\theta$, F-U and T-$\alpha$ diagram inreal time, a new deformaiton gage for mixed mode loading was proposed using the optical position sensing device(PSD). The elastic-plastic fracture toughness test was carried out with an aluminum alloy. The loading apparatus was designed and manufactured for this experiment. For the loading condition of the crack initatio in the mixed mode, the MMT -3(mode I+ mode II+ mode III) has the lowest values out of the all specimens. This implies that MMT-3 is possible of the crackinitation at lower load, if the specimen acts on together with the torque under the same loading condition. An elastic-plastic fracture toughness test using the PSD brings a successful experimentation in measuring the crack deformation(mode I+ mode II+ mode III).

Development of Thermocouple Sensor for Thermal Boundary Layer Measurement (온도 경계층 측정용 열전대 센서 개발)

  • Seo, Jongbeom;Han, S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.983-990
    • /
    • 2014
  • This research focused on designing an appropriate thermocouple sensor for a thermal boundary layer with a large temperature gradient. It was designed to minimize the conduction error from a constant temperature wall in a boundary layer. A $79.9-{\mu}m$ thermocouple was chosen, and a five-axis device jig was developed to fabricate a butt-welded thermocouple, which is different from arc-welded junction thermocouples. This was used to minimize the size of the thermocouple junction. In addition to fabricating butt-welded thermocouples, a thorough calibration was conducted to decrease the internal error of a multimeter to ensure that the data from the butt-welded and regular thermocouples were almost the same. Based on this method, a butt-welded thermocouple with a small junction was found to be suitable for measuring the temperature in a thermal boundary layer with very large thermal gradients. Using this thermal boundary layer probe, the thermal boundary layers in a turbine cascade were measured, and the Nusselt numbers were obtained for the turbine endwall.

Evaluation of Characteristics of Tack Coat for Porous Pavement using Direct Shear Test (직접 전단 실험을 통한 배수성포장용 택코트 특성 평가)

  • Kim, Nak-Seok;Hong, Eun-Cheol;Jo, Shin-Haeng
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • The main objective of this study is to develop a test for measuring the bond shear strength between pavement layers. The research is also conducted to evaluate tack coat materials and application rate in porous pavement. The experiment includes using two types of emulsions (RSC-4, Modified Emulsion) and a asphalt binder type (HM-1). HM-1 was developed to be applied in porous pavement. The bond shear strengths were measured by a direct shear type device under various test conditions. The shear strength may not be appropriate in the evaluation of the bond shear strength, while the toughness of the test may be useful. In case of the tack coat application rate in porous pavement, RSC-4 has to be used a minimum amount of $0.8l/m^2$ and modified emulsion asphalt has to be applied a volume of use $0.5{\sim}0.6l/m^2$. HM-1, asphalt cement type, is far stronger bond shear strength than emulsified asphalt tack coat and had showed the excellent trackless property.

A Mining-based Healthcare Multi-Agent System in Ubiquitous Environments (마이닝 기반 유비쿼터스 헬스케어 멀티에이전트 시스템)

  • Kang, Eun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2354-2360
    • /
    • 2009
  • Healthcare is a field where ubiquitous computing is most widely used. We propose a mining-based healthcare multi-agent system for ubiquitous computing environments. This proposed scheme select diagnosis patterns using mining in the real-time biosignal data obtained from a patient's body. In addition, we classify them into normal, emergency and be ready for an emergency. This proposed scheme can deal with the enormous quantity of real-time sensing data and performs analysis and comparison between the data of patient's history and the real-time sensory data. We separate Association rule exploration into two data groups: one is the existing enormous quantity of medical history data. The other group is real-time sensory data which is collected from sensors measuring body temperature, blood pressure, pulse. Proposed system has advantage that can handle urgent situation in the far away area from hospital through PDA and mobile device. In addition, by monitoring condition of patient in a real time base, it shortens time and expense and supports medical service efficiently.

A Study on the Technical Regulation of Weak Electric Filed Strength Radio Equipment about 58kHz Frequency Band (58kHz 대역 미약 전계강도 무선기기 기술 기준에 관한 연구)

  • Park, Hyoung-Keun;Kim, Sun-Youb;Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2319-2325
    • /
    • 2009
  • This paper compared the output limits value of the Korean weak electric field strength wireless device in the 58kHz band with the standard values of foreign countries. Through this, the study confirmed that the Korean regulation was lower by about 50dB than those of the USA or Europe. In order to prove this, the study measured outputs by entrusting the 58kHz EAS system to two measuring companies. As a result of these measurements, electric field strengths were shown to be $112dB{\mu}V/m$ and $08dB{\mu}V/m$ respectively, and these values were confirmed to exceed the current Korean standard of $102.7dB{\mu}V/m$. Accordingly, it is deemed necessary to review the specifications of the Korean standard in the 58kHz band.

COLOR ANALYSIS OF THE NATURAL TEETH WITH A MODIFIED INTRAORAL SPECTROPHOTOMETER (구내용 분광광도계를 이용한 자연치의 색상분석)

  • Cho, Kyung-Mo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.223-235
    • /
    • 1998
  • The recognition of the esthetics as well as their function of the teeth in the dental field is growing. Evaluating the esthetics of a tooth concerns shape, texture, and color. And among these, color has been the most difficult element to make natural expression. Color is a very subjective element affected by many different factor like light source, object, observer. Numerous efforts to quantifying color has been made. Currently the use of colorimeter and spectrophotometercolor that the color measuring device has been suggested. In this study, the normal range of the tooth color in canines, lateral incisors and central incisors for Koreans was evaluated with a modified spectrophotometer for intraoral use. The color differences in terms of teeth positions, age and area within the tooth was evaluated and comparatively analyzed. Results were as follow ; 1. In all age groups, the central incisors are most bright and least yellowish opposit to the canines are most dark and yellowish. The central incisors and lateral incisors showed the similar color patterns. 2. In the comparison between gender, it showed that in the 10' s group male have more yellowish, the 20's female have lighter and more redness, the 30's indicated more redness in female and in the 40's the lightness is more in female. 3. With aging, there was no significant change in $L^*$ and $a^*$ coordinates but a shift was in $b^*$ to yellowish in the 30' sand 40's in central incisors. Lateral incisors and canines showed a lighter and more yellowish tooth color with an irregular change of color coordinate in $a^*$. 4. In all teeth the middle and cervical portion showed close correlation with over 0.7(0.05>p) but color ($a^*$, $b^*$) showed higher correlation than lightness($L^*$). 5. It has been shown that through the regression test the cervical color could be calculated by the middle color value.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.