• 제목/요약/키워드: Measuring Valve

검색결과 128건 처리시간 0.021초

정상유동 장치에서 유동 특성 평가 방법에 대한 연구(5) - 평가위치의 영향 (Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(5)-Effect of Evaluation Position)

  • 조시형;엄인용
    • 한국자동차공학회논문집
    • /
    • 제25권2호
    • /
    • pp.179-189
    • /
    • 2017
  • This paper is the fifth investigation on the methods of evaluating flow characteristics in a steady flow bench. In previous studies, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation may lead to serious problems. In addition, though the velocity profiles were improved as the measuring position went downstream, the distributions were far from ideal regardless of the valve angle and evaluation position. The eccentricities were also not sufficiently small to disregard the effect on impulse swirl meter (ISM) measurement. Therefore, the effect of these distribution and eccentricity changes according to the positions needs to be analyzed to discuss the method of flow characteristics estimation. In this context, the effects of evaluation position on the steady flow characteristics were studied. For this purpose, the swirl coefficient and swirl ratio were assessed and compared via measurement of the conventional ISM and calculation based on the velocity by particle image velocimetry(PIV) from 1.75B, 1.75 times bore position apart from the cylinder head, to the 6.00B position. The results show that the swirl coefficients by ISM strictly decrease and the curves as a function of the valve lift become smooth and linear as the measuring position goes downstream. However, the values through the calculation based on the PIV are higher at the farther position due to the approach of the tangential velocity profile to ideal. In addition, there exists an offset effect between the velocity distribution and eccentricity in the low valve lift range when the coefficients are estimated based on the swirl center. Finally, the curve of the swirl ratio by ISM and by PIV evaluation as a function the measuring position intersect around 5.00B plane except at $26^{\circ}$ valve angle.

밸브 간극에 따른 밸브트레인 거동 연구 (Study of Valve Train Motion According to Valve Clearance)

  • 민선기
    • 한국융합학회논문지
    • /
    • 제8권10호
    • /
    • pp.193-199
    • /
    • 2017
  • 기계적 태핏은 유압 태핏과 비교하여 원가와 마찰 손실을 줄일 수 있어 사용된다. 그러나 기계적 태핏은 캠과 밸브 사이의 간극을 조절하는 기능이 없으므로 밸브의 열팽창을 고려하여 캠과 밸브 사이의 거리를 측정하여 선정된다. 그러므로 충분한 워밍 업 후에는 밸브 간극이 거의 없지만 그 전에는 밸브 간극이 존재한다. 특히 냉간 작동 조건에서는 비교적 큰 편이고 소음과 진동 같은 문제를 발생시킬 수 있다. 본 논문에서는 밸브 간극을 변경시켜 가며 각각의 조건에서의 밸브 리프트, 속도, 가속도, 시팅 속도, 바운싱 높이 등에 대하여 시험과 해석을 통하여 연구되었다. 밸브 간극이 증가할수록 램프 구간이 감소하게 되어 밸브의 거동에 좋지 않은 영향을 미치는 것을 확인할 수 있었다.

엔진 토크의 간접적(間接的)인 측정(測定) 방법(方法)에 관한 연구(硏究) (Evaluation of Indirect Methods of Engine Torque Measurement)

  • 류관희;강성봉
    • Journal of Biosystems Engineering
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 1991
  • This study was carried out to evaluate indirect methods of engine torque measurement. Three indirect methods based on throttle valve opening, exhaust gas temperature and inlet air pressure were compared. The indirect method based on throttle valve opening appeared to be the most satisfactory in terms of accuracy and response time. The discrepancies between the direct method and the indirect method based on throttle valve opening in measuring engine torque were 2% on t he average.

  • PDF

버터플라이 밸브의 유량측정 불확도에 대한 영향 (Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement)

  • 윤석호;이정호;유청환;박상진;정장환
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

실린더 헤드 스월 측정 및 자동화 방법에 관한 연구 (A Study on Measurement and Automation Method of Cylinder Head Swirl)

  • 이충훈
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

Multi-measuring기법을 이용한 원전 제어밸브의 누설진단 (Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring)

  • 김성영;김영범;김봉호;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

엔진내구시험을 통한 Valve Train 수명예측에 관한 연구 (2) (A Study of Valve-train Life Time Estimate in Engine Durability Test (2))

  • 김재진;이환희;명광희;민병두
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.75-80
    • /
    • 2014
  • In previous study, make an attempt to estimate exhaust valve seat and seat-ring wear acceleration factor for engine durability test with measuring and consideration of wear mechanism. But found abnormal initial wear rate in exhaust valve seat-ring. And have to improve exhaust valve seat-ring wear rate for reliability reason, because next GDI/Turbo engine is based on this engine and GDI/Turbo engine have higher combustion pressure and higher thermal load. In this study, Trying to find the cause of abnormal wear factor, improve valve-train durability by change specification & design of parts and verify variant parts for improving durability of valve-train. And then I would like to propose a design guide line of valve-train system in a reliability point of view, besides make a complement of previous study.

상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구 (A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve)

  • 김태준;이중섭;이치우
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.307-313
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.

비파괴법에 의한 선박용 디젤엔진 배기밸브의 열화도 평가에 관한 기초적 연구 (Fundamental Study on Degradation Evaluation of Marine Diesel Engine Exhaust Valve by Nondestructive Test)

  • 심규현;김현수;남기우
    • 동력기계공학회지
    • /
    • 제3권4호
    • /
    • pp.51-56
    • /
    • 1999
  • The ultrasonic method, which is well known as nondestructive test method, is widely used to evaluate the material damage due to degradation. However, this method is just used for measuring the crack size and the thickness loss of the tube. The purpose of this study is to investigate the applicability of the ultrasonic technique for the evaluation of marine diesel engine exhaust valve and to suggest the correlations between the ultrasonic characteristics and valve degradation. From the evaluation of the results obtained, the technique of using the ultrasonic property was founds to be a efficient method to evaluate the degree of marine diesel engine exhaust valve by nondestructive test.

  • PDF

공압서보밸브 KS규격 정립에 관한 연구 (A Study of Korean (Industrial) Standards for Pneumatic Servo Valve)

  • 김동수;이원희;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1231-1234
    • /
    • 2003
  • Pneumatic servo valve which is widely applied in industrial world is advanced technology compounded with electric, electronic and machine. And It is consist of Linear Force Motor. Spool Commutation Mechanism and Microprocessor. In this study, we accomplished test method of Linear Force motor test, Static characteristic test, Dynamic characteristic test for KS(Koran industrial standard) of Pneumatic servo valve. we accomplished study about the main item of Static characteristic test which is related to unload flow characteristic test. And Dynamic characteristic test was step input test and frequency response test. Specially about frequency response test, There was a difficulty resulting from the time delay problem caused by the basic compressibility of air. In order to solve the problem in this study. we proposed two methods. First, displacement of the servo valve spool was directly measured by using a laser sensor. Second, method of calculating control flow by measuring pressure and temperature of chamber.

  • PDF