• Title/Summary/Keyword: Measuring Tube

Search Result 344, Processing Time 0.026 seconds

Development of inside-out probes for both Nuclear Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy (핵자기공명 영상법과 핵자기공명 분광법을 위한 뒤집음-탐침의 개발에 대한 연구)

  • Lee, Dong-Hun;Go, Rak-Gil;Jeong, Eun-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.309-316
    • /
    • 1995
  • RF (radio-frequency) probes of Nuclear Magnetic Resonance are one of the important factors and should be designed and built properly depending upon the geometry of the samples and the information. In general there are two kinds of rf probes : one encircles the sample while the other is placed on the surface of the sample. However, in case that the samples on human internal organs have a tube shape, the two kinds of rf probes, as specified above, are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios (SNR's). In this case a probe should be positioned as close to the area as possible by putting the probe in the tubelike sample to improve filling factor In the present study inside-out probes have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SWR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high feasibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.

First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil (SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템)

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Kwon, H.;Kim, K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

A Study on the Improvement of Greenhouse Frame to Bear the Heavy Snow (적설하중 증가에 대비한 비닐하우스 골조 성능의 개선 연구)

  • Jung, Hyunjin;Yang, Sanghyun;Lee, Taehee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2242-2248
    • /
    • 2015
  • The damages from greenhouses collapsing due to heavy snowfall in winter are increasing, and the current frames of greenhouse are required to be improved. This study was conducted to seek solutions to improve intensities of greenhouse frame to bear heavy snows. We investigated a structural safety of greenhouses by calculating axial force, bending moment and combined stress when snow load was increased up to 30% of the current standard ground snow load of the conventional greenhouse types (07-single type 3, 07-single type 18) in the three regions (Gyeongju, Sokcho, and Gangneung) where were most damaged by recent heavy snows. In addition, we determined what structural type was most efficiently bear snow loads by measuring the differences between the load bearing strength according to the changes of tube diameter and thickness or the rafter spacing of greenhouses circular pipe. MIDAS GEN program was used in the analysis. As a result, with the snow load increase of 30%, greenhouse in Gyongju was still safe, but in Sokcho was at a risk, and in Gangneung was possible to be collapsed even in the current snow load. Increased pipe diameter than increased pipe thickness was more efficient in terms of improved performance of greenhouse structure. Accordingly, it is suggested to revise standards of greenhouse to increase pipe diameter of rafter for minimizing damages by heavy snow.

ADHESION OF CANDIDA ALBICANS ISOLATES TO ACRYLIC RESIN IN RELATION TO SALIVARY GLYCOPROTEINS IN DENTURE STOMATITIS PATIENTS (의치 구내염 환자에서 분리한 Candida albicans의 아크릴 수지에 대한 부착성과 타액 단백질과의 상호 관계)

  • Oh, Jung-Hwan;Choi, Boo-Byung;Choi, Dae-Gyun;Woo, Yi-Hyung;Lee, Sung-Bok;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.698-713
    • /
    • 1999
  • Adherence of Candida albicans(C. albicans) to the surface of a denture is believed to be an initial and essential step in the formation of denture-induced stematitis. Previous studies have provided enormous infomation on the relationship between composition of palatine gland/parotid saliva and upper denture stomatitis. Relatively little information is available on the correlation between lower denture stomatitis and sublingual-submandibular ( SLSM ) saliva. The plaque samples were collected from the two sites($100mm^2$) on the inner surface of lower partial denture corresponding to the stematitis and healthy region of the lower partial dentures of 12 denture stomatitis patients and 6 nor-mal persons who wore lower partial dentures. The samples were plated to isolate C. albicans on a selective Saboraud's dextrose agar plate and the isolates were identified by germ tube test and gram staining. The subjects were divided into group I (stomatitis with C. albican), group II (lesion without C. albicans), group III (no lesion but C. albicans), and group IV (normal and healthy denture wearer). Individual SLSM saliva($20{\mu}g$ of protein) was analyzed by SDS-PAGE (SDS -poly-acrylamide gel electrophoresis) with Coomassie brilliant blue and PAS(Periodic Acid Schinff) stain-ing. The salivary proteins separated in the polyacryamide gels were subjected to immunoblot anaysis using anti-lactoferrin, anti-sIgA, and anti-secretory component of sIgA. In this study using custom made acrylic denture resin beads(5mm in diameter) coated with stimulated individual SLSM saliva, the binding ability of individual C. albicans strains to the beads was observed. Levels of C, albicans adhered to the acrylic resin beads were determined by measuring the optical density of the bound C. albicans to the beads at 580nm. The results showed that a higher number of C. albicans was observed in the lesion site than healthy site. The saliva of group I contained more high molecular weight glycoprotein(mucin, MGI) as compared to group II, III and IV. And lactoferrin and sIgA affected to the binding ability of C. albicans to acylic resin beads. Binding ability of individual C. albicans to the acrylic resin coated with respective individual saliva was found to be greater in group I than the other 3 groups. And when bound cells of C. albicans isolated from individual subject #2 to the saliva coated beads were used binding ability of subject #2 saliva coated beads was founed to be greater than the other sutjects. These results suggested that denture induced stomatitis is related to individual patient's salivary protein composition, especially MG-1. Future studies will be directed toward saliva exam-ination of patients who have general disease and analysis of pellicles formed on prosthesis with respect to oral disease.

  • PDF

Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators (진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교)

  • Han, Beom-Hui;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;You, In-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.389-394
    • /
    • 2012
  • In this study, based on IEC 60601-2-54 standard load conditions presented in the limited interval over the air kerma at the absolute linearity closely evaluated by measuring the X-ray results were as follows: 10 units targeted all Diagnostic X-ray generating device (DR) presented in the IEC 60601-2-54 standard linearity of air kerma emerged as inappropriate, the general evaluation of the dose linearity from four in the top 50% and 80 kVp % of the two measurement series were as irrelevant all the rest from six of the top tube voltage of 50% and 80% of the two measurement series, appeared in all suitable. Presented in IEC 60601-2-54 standard dose linearity testing and conventional linearity tests showed many differences. IEC 60601-2-54 standard linearity in the proposed international standards of air kerma is the recommendation of the existing dose linearity considerably more feasible, and to quantify the amount of radiation as the standard suggested by the standard IEC 60601-2-54 air kerma of a diagnostic X-ray imaging device linearity performance management is considered key elements in the critical appraisal.

Study on Exposure Dose and Image Quality of Operator Using Shielding Material in Neuro Interventional Radiology (뇌혈관 중재적 시술에서 차폐체를 이용한 시술자의 피폭선량과 화질에 관한 연구)

  • Kim, Dae-ho;Kim, Sang-hyun;Lee, Young-jin;Lim, Jong-chun;Han, Dong-kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.579-587
    • /
    • 2017
  • Although interventional procedures use very low tube currents, there is a high risk of exposure to radiation as well as the operator due to long-term radiation exposure. The purpose of this study is to investigate the effects of radiation dose on the quality of the operator by measuring the dose received by the operator in the interventional procedure of the cerebral vascular system and finding the shielding material and shielding method which can effectively shield the exposure from the medical radiation. And to find a way to minimize it to the extent that it does not. As a result, when the newly designed shielding system with Nano Tungsten material was used, it was confirmed that the mean dose was reduced by 7.95% on average by the operator. Also, the PSNR results were measured to be 38.44 dB when using the designed shielding material, and it was confirmed that Nano Tungsten does not affect the image quality. In conclusion, the Nano Tungsten shielding material proved to be capable of significantly reducing the operator radiation dose, without affecting the image quality. The use of the above materials is expected to solve the problems related to the harmfulness and economical efficiency of the human body and the environment, which have recently become an issue of shielding materials.

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

THE SHEAR BOND STRENGTH BETWEEN DICOR AND SEVERAL VENEERING PORCELAINS (Dicor와 수종 전장도재간의 전단결합강도)

  • Ryoo, Kyung-Hee;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.165-179
    • /
    • 1993
  • Dicor has not been prescribed routinely, in spite of many advantages, because of esthetic limitations by excessive translucency and external shading. In an attempt to solve these problems, the technique of veneering Dicor by aluminous poreclain has been used and recently Dicor Plus system was developed. The purpose of this study was to evaluate the compatibility between Dicor and several veneering porcelains by measuring the shear bond strength and observing the failure mode and interface appearance with SEM. Total 55 Dicor disks(10.0mm diam. X 3.0mm thickness) were fabricated by lost wax technique and divided into five groups of 11. Veneering porcelains such as Dicor Plus, Vitadur Alpha, Vitadur N, Vivodent, and Ceramco II were built up over the center of the treated Dicor surface using paper tube(5.0mm diam. X 4.0mm height) and fired according to the manufacturesr’instructions. A representative sample from each group was completely embedded in epoxy resin and crosssectioned, and remaining 50 samples were embedded in epoxy resin with the bonded area perpendicular to table base. The shear bond strengths were measured by applying the shear load parallel to Dicor surface close to the bonded area. Failure modes and interface appearances were observed using SEM at 15 and 1000 magnification respectively. The obtained results were as follows : 1. The mean shear bond strengths showed Dicor-Dicor Plus(10.53 MPa); Dicor-Vitadur Alpha(8.84 MPa); Dicor-Vitadur N(7.37 MPa); Dicor-Vivodent(4.28 MPa); Dicor-Ceramco II(0.89 MPa). 2. The shear bond strength of Dicor-CeramcoII was significantly decreased compared with Dicor-Dicor Plus(p<0.01), but had no significant difference compared with Dicor-Vivodent(p>0.01). 3. The shear bond strengths of Dicor-Vitadur Alpha and Dicor-Vitadur N were not significantly different compared with Dicor-Dicor Plus(p>0.01). 4. SEM examination of bond failure modes revealed that Dicor-Dicor plus, Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited cohesive failure within Dicor and Dicor-Vivodent exhibited adhesive failure. And Dicor-Ceramco III exhibited adhesive failure and cohesive failure within CeramcoIII together. 5. SEM examination of interfaces revealed that Dicor-Dicor Plus exhibited the most tight contact and Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited acceptible contacts. But Vivodent exhibited discontinuous gap and Ceramco II exhibited large continuous gap.

  • PDF