• Title/Summary/Keyword: Measuring Station

Search Result 257, Processing Time 0.028 seconds

A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island (W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례)

  • Lee, Jong-Won;Park, Moon-Soo;Won, Wan-Sik;Son, Seok-Woo
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

Study on developing CSEM Sratch Tester of tongue rail (텅레일 밀착력 측정기 개발에 관한 연구)

  • Lee, Nam-Il;Ko, Yang-Ok;Jung, Ho-Hung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1663-1668
    • /
    • 2010
  • The terms of track is a train-only line for a train service, in premises of station of a station, that the unit over the track for turnout the track from one track to another track, which it changes the course from the main track that is used for operating a train to the side track, is called a turnout The stick strength of tongue rail is adjusting uniform pressure on the both sides, the adhesion strength between a basic rail and tongue rail has to maintain over 100kg of power value to open over 1mm the ends. This study suggested developing a measuring instrument that can measure a basic rail and the stick strength of a movable rail in according with a switch, such as a switch point, and a performance test. This study ties to be helped that it improves measuring usability for the maintainers through improving quality in a stick measuring instrument, that it solves a technique in the site difficulties through improving a measuring instrument, with reducing the obstacles and expenses.

  • PDF

The Development of Underwater Robotic System and Its application to Visual Inspection of Nuclear Reactor Internals (수중로봇 시스템의 개발과 원자로 압력용기 육안검사에의 적용)

  • 조병학;변승현;신창훈;양장범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1327-1330
    • /
    • 2004
  • An underwater robotic system has been developed and applied to visual inspection of reactor vessel internals. The Korea Electric Power Robot for Visual Test (KeproVt) consists of an underwater robot, a vision processor-based measuring unit, a master control station and a servo control station. The robot guided by the control station with the measuring unit can be controlled to have any motion at any position in the reactor vessel with $\pm$1 cm positioning and $\pm$2 degrees heading accuracies with enough precision to inspect reactor internals. A simple and fast installation process is emphasized in the developed system. The developed robotic system was successfully deployed at the Younggwang Nuclear Unit 1 for the visual inspection of reactor internals.

  • PDF

The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station (수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;CHUNG, JIN BAE;HONG, SUK JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.

Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400 (APR1400 원자로 내부구조물 종합진동평가 측정센서 선정)

  • Ko, Do-Young;Lee, Jae-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF

A Study on the Automatic Measurement at an Unmanned Measuring Station Using Image Processing and Wireless Networks (화상처리 및 무선네트워크를 이용한 무인 측정 지점에서의 원격 계측 자동화에 관한 연구)

  • Lee, Han-Jun;Cha, Myung-Suk;Lee, Choong-Hoon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.15-22
    • /
    • 2007
  • An automatic measurement system which collects experimental data at an unmanned station where the networking to the internet could not be accessed was developed. With a Robo-rail accessing to the unmanned station, wireless local networking between server PC at the Rob-rail and client PC at the unmanned station is possible within 30 m from an access point equipment located at the unmanned station. An algorithm for transferring the data file which is saved in the client PC at the unmanned station to the server PC in the Robo-rail was proposed. IEEE-1394 camera was used to collect the data at the client PC. An extracting program from the IEEE-1394 captured images to character data and number data was developed using image processing technique, which drastically reduces the size of data file comparing to that of the raw image file.

Development of IoT-based PM2.5 Measuring Device (사물인터넷 기반 초미세먼지(PM2.5) 측정 장치 개발)

  • Loh, Byoung Gook;Choi, Gi Heung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • An IoT-based particulate matter (PM2.5) sensing device (PSD) is developed. The PSD consists of a PM2.5 sensor, signal processing circuit, and wi-fi enabled-microprocessor along with temperature and humidity sensors. The PSD estimates PM2.5 density by measuring light scattered by PM2.5. To gauge performance of the PSD, PM2.5 density of open air was measured with the PSD and compared with that of the collocated-government-certified measuring station. Measurements were taken at a sampling frequency of 100 Hz and moving-averaged to remove measurement noise. When compared to the result of the measuring station, average percentile error of PM2.5 density from the PSD is found to be 31%. A correlation coefficient is found to be 0.72 which indicates a strong correlation. Instantaneous variation, however, may far exceed average errors, leading to a conclusion that the PSD is more suitable for estimating average trend of PM2.5 density variations than estimating instantaneous PM2.5 density.

An Examination of Customer Usage for Major Railway Station Buildings (주요 철도역사의 고객이용패턴 조사분석)

  • Lee, Jun-One;Bahn, Sang-Woo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.698-705
    • /
    • 2008
  • Under the rapid change in environment of our society and culture, it is also called for a reform in railway management that has traditionally focused on transportation service. Thus developing a business model to use station buildings as a new source of profit has become a promising core business of railway companies. This study aims to find a way to maximize profits by strategically utilizing station buildings and thereby increasing accessibility to customers and consolidating facilities as a key service point. The subjects of this study include eight station buildings that can represent three types of railway stations including departure stations, junction stations, and metro stations. The researcher conducted an analysis on moving lines for examining user distribution and facility utilization within the selected buildings, a survey for collecting basic information on usage and measuring customer satisfaction of facility in the buildings, and a sight analysis to examine accessibility to the station buildings. On the basis of these analyses, the researcher examined the correlations between convenience, visibility, recognizability and functionality with regard to commerce, amenities, couches, direction boards, etc. within station waiting rooms. On the basis of the above analyses, the researcher provides a scheme to increase profitability in railway operation business and customer benefits of using station buildings by drawing up a plan to improve usage of station buildings and maximize profit-making potential for each category of station buildings.

  • PDF

Analysis of Electrical Loads in the Urban Railway Station by Big Data Analysis (빅데이터분석을 통한 도시철도 역사부하 패턴 분석)

  • Park, Jong-young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.460-466
    • /
    • 2018
  • For the efficient energy consumption in an urban railway station, it is necessary to know the patterns of electrical loads for each usage in detail. The electrical loads in an urban railway station have different characteristics from other normal electrical load, such as the peak load timing during a day. The lighting, HVAC, communication, and commercial loads make up large amount of electrical load for equipment in an urban railway station, and each of them has the unique specificity. These loads for each usage were estimated without measuring device by the polynomial regression method with big data such as total amount of electrical load and weather data. In the simulation with real data, the optimal polynomial regression model was third order polynomial regression model with 9 or 10 independent variables.

A Study on the out-diameter measuring machine by the LVDT sensors (LVDT 센서를 이용한 외경 측정 방안에 대한 연구)

  • Hwang J.H.;Roh J.H.;Park Ki-Hong
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF