• Title/Summary/Keyword: Measurement standards

Search Result 1,400, Processing Time 0.026 seconds

Ultrafine Particle Toxicities, Current Measurement Techniques and Controls (Ultrafine Particle의 독성, 측정방법 및 관리)

  • Lee, Su-Gil;Kim, Seong-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.

Development of Conductivity Standards for Metals using the van der Pauw Method (van der Pauw method를 이용한 금속도전율 표준시편 개발)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Lee, Sang-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1617-1620
    • /
    • 2013
  • The widely-used measurement methods for conductivity of non-magnetic metals are van der Pauw method, Two Point Probe method and Eddy Current method. Among them a more simpler and easier method is the Eddy Current method and an instrument using the method is a Conductivity Meter which can measure a conductivity by contacting its probe on a sample surface. However, conductivity standards are essentially needed to confirm the meter's performance or to calibrate it. In this study, six kinds of the standards which are made of Cu, Al-1, Al-2, brass, Zn and SUS-316 are developed and conductivity ranges for the standards are 2.27 %IACS ~ 101.6 %IACS with measurement uncertainty of less than 0.3 %.

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

  • Kang, Ji Hwan;Kim, Yong Doo;Lee, Jinhong;Lee, Sangil
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.202-211
    • /
    • 2021
  • Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

Measurement of triple point of water temperature for improvement of the national standards and key comparison (국가표준향상과 핵심국제비교를 위한 물의 삼중점 온도 측정)

  • Yang, Inseok;Lee, Young Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-356
    • /
    • 2021
  • The Korea Research Institute of Standards and Science (KRISS), a National Metrology Institute of Korea, participated in the second-round of the international key comparison CCT-K7.2021 of triple point of water (TPW) cells. For the key comparison, three TPW cells, one of which had been used in the old CCT-K7 comparison, were assigned as the national standard of the TPW. The temperature difference (ΔT) between the average of the new and old national standards and ΔT between the new national standard and the transfer standard were measured. The comparison between the new and old national standards indicated a temperature increase of 69.5 µK after both the standards were corrected for the isotopic composition. The uncertainty of the national standard of the TPW temperature was 28 µK, and the uncertainty of ΔT was 14 µK. Three aspects of improvements in the new comparison compared to the old one were noted: (1) inclusion of two quartz cells in the national standard strengthens its long-term stability; (2) the standard deviation associated with the measurement of ΔT was reduced from 21 µK to 9.6 µK; (3) and the measured immersion profile of the TPW cells was much closer to the theoretically predicted dependence.

A Study on Work Measurement System Development Applying MODAPTS Technique (MODAPTS 기법을 이용한 작업시간 관리시스템에 관한 연구)

  • 신현표;송한상
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.16 no.27
    • /
    • pp.43-49
    • /
    • 1993
  • The purpose of this study is to develope a computer-generated work measurement system for creating and maintaining standard data as well as labor standards applying MODAPTS(Modular Arrangement of Predetermined Time Standards) technique. The system consists of three major parts. The first part is a work measurement program applying MODAPTS technique for work standards. The second part is a work scheduling program which calculate each operator's machine and job allocations, operation and load schedules, wage and wage incentives and direct labor costs etc. The last part is the case study application program for R-Instrument Manufacturing Industry. The whole system is programmed by dbase-Ⅲ and by pop-up mu for IBM PC compatibles.

  • PDF

Development of a V-Band Millimeter-Wave Source Module

  • Kwon, Jae-Yong;Lee, Dong-Joon;Bakti, Aditia Nur;Angin, Windi Kurnia Perangin
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.225-228
    • /
    • 2016
  • KRISS-V, a V-band millimeter-wave source module for a primary RF power standard and calibration system developed by the Korea Research Institute of Standards and Science is here presented. The output power of KRISS-V is several times higher than that of commercial amplifier/multiplier chains and is highly stable (the standard deviations of output power are less than 0.01% in the worst case). The spectral purity of KRISS-V is high enough to consider it a single-tone signal generator. We also added programmable attenuation capability to KRISS-V for remote power control. Moreover, the in-house source module is cost-effective and adaptable to various measurement schemes. The structure of the model as well as detailed component information are introduced so that it can be reproduced.

Development of Inner Pressure Measurement System for Hermetic Sealed Small Components (밀폐된 소형부품의 내부압력 측정장치 개발)

  • Hong, S.S.;Lim, I.T.;Lim, J.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • The measurement device of internal pressures of small components sealed hermetically was developed. The internal pressure of a sample measured with this device was 43.151 kPa, and the expanded uncertainty ($\kappa$=2) was 741 Pa. The resultant measurement ability of internal pressures in small vacuum components, which had been almost impossible previously, shows the possibility of internal vacuum detection of hermetically sealed parts.

Mass Standards Calibration through Internet (인터넷을 이용한 표준분동 교정 활용)

  • 이우갑;정진완;김광표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1109-1112
    • /
    • 2003
  • Information technology has enabled mass standards calibration to be performed through internet. For this, an automatic weight handler was manufactured. During the operation the images of weight operation and the system are provided via the measurement system and a web server. The measurement system consists of a balance, a weight handler, instruments for environment measurement and a PC. The weight handler automatically loads and unloads weights on and from the weighing pan. The weight handler allows 6 series weights to be operated for weight calibration of 100-50-20-20-10-10 gram series weight. This capability could be used for "remote training" for series weight calibration.

  • PDF

Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment (비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발)

  • Kim, In-Seon;Kim, Jin-Mok;Park, Yong-Ki
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

Magnetocardiogram Measurement of Laboratory Rat (백서를 이용한 심자도 신호 측정)

  • Kim, I.S.;Ahn, San;Kwon, H.C.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • We have developed a high-$T_c$ SQUID magnetocardiogram (MCG) system for small laboratory animals. White noise of the measurement system was about 30 fT/$Hz^{1/2}$ when measured in a magnetically shielded room. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 30 pT. We could observe well defined P-, QRS-, and T-waves from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of the heart disease model by using a laboratory rat.