• 제목/요약/키워드: Measurement of Stiffness

Search Result 465, Processing Time 0.019 seconds

A Recommendation of the Technique for Measurement and Analysis of Passive Surface Waves for a Reliable Dispersion Curve (신뢰성 있는 분산곡선의 결정을 위한 수동표면파 측정 및 분석기법의 제안)

  • Yoon, Sung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.47-60
    • /
    • 2007
  • Conventional active surface wave measurements performed using a transient or continuous source are often limited in the maximum depth of penetration due to the difficulty of generating low-frequency energy with reasonably portable sources. This limitation may inhibit accurate seismic site response calculations because of the inability to define deeper subsurface structure. By measuring surface wave generated by passive sources including microtremors and cultural noise, it is possible to overcome this problem and develop soil stiffness profiles to much larger depth. Reliability of dispersion estimates from the passive surface wave measurements is critical to present reliable shear wave velocity profiles and can be improved by the measurements and analyses of passive surface waves based on correct understanding of systematic errors included in passive dispersion data. In this study, the systematic errors caused by poor wavenumber resolution and energy leakage into sidelobes in passive tests are mainly explored. Recommendations for reliable passive surface wave measurements and dispersion estimates are presented and illustrated at a site in San Jose, California, U.S.

Study on Measuring Mechanical Properties of Sport Shoes Using an Industrial Robot (산업용 로봇을 이용한 스포츠화의 운동역학특성 측정에 관한 연구)

  • Lee, Jong-Nyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3833-3838
    • /
    • 2009
  • This paper introduces a measurement system for mechanical properties of sport shoes using an industrial robot. The robot system used in this paper is a commercial Puma type robot system(FARA AT2 made by SAMSUNG Electronics) with 6 joints and the end-effector is modified to produce a human walking motion. After analyzing human walking with a high speed video camera, each joint angle of the robot system is extracted to be used in the robot system. By using this system, ground impact forces were measured during stepping motion with 3 different shoe specimens made of 3 different hardness outsoles, respectively. As other mechanical properties, both bending moments to bend the toe part of the same specimen shoes and pronation quantities during walking motion were measured as well. In the impact test with the same depth of deformation under the ground level, the effect of the outsole hardness was clearly appeared such that the harder outsole produces the higher ground reaction force. The bending test and the pronation test also show proportional increments in the bending stiffness and the moment Mx according to the outsole hardness. Throughout such experiments, the robot system has produced consistent results so that the system could be used in obtaining valuable informations for a shoe designing process.

Characteristics of Sand-Silt Mixtures during Freezing-Thawing by using Elastic Waves (탄성파를 이용한 모래-실트 혼합토의 동결-융해 특성)

  • Kang, Mingu;Kim, Sangyeob;Hong, Seungseo;Kim, Youngseok;Lee, Jongsub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.47-56
    • /
    • 2014
  • In winter season, the pore water inside the ground freezes and thaws repetitively due to the cold air temperature. When the freezing-thawing processes are repeated on the ground, the change in soil particle structure occurs and thus the damage of the infrastructure may be following. This study was performed in order to investigate the stiffness change of soils due to the freeze-thaw by using elastic waves. Sand-silt mixtures are prepared with in the silt fraction of 40 %, 60 % and 80 % in weight and in the degree of saturation of 40 %. The specimens are placed into the square freezing-thawing cell by the temping method. For the measurement of the elastic waves, a pair of the bender elements and a pair of piezo disk elements are installed on the cell, and a thermocouple is inserted into soils for the measurement of the temperature. The temperature of the mixtures is decreased from $20^{\circ}C$ to $-10^{\circ}C$ during freezing, is maintained at $-20^{\circ}C$ for 18 hours, is gradually increased up to the room temperature of $20^{\circ}C$ to thaw the specimens. The shear waves, the compressional waves and the temperature are measured during the freeze-thaw process. The experimental result indicates that the shear and the compressional wave velocities after thawing are smaller than those of before freezing. The velocity ratio of after thawing to before freezing of shear wave is smaller than that of the compressional wave. As silt fraction increases from 40 % to 80 %, the shear and compressional wave velocities are gradually increased. This study suggests that the freezing-thawing process in unsaturated soil loosens the soil particle structure, and the shear wave velocity reflects the effect of freezing-thawing more sensitively than the compressional wave velocity.

Rheological Properties of Chitosan Manufactured from the Pens of Domestic (Todarodes pacificus) and Foreign (Ommastrephes bartrami) Squid (연안산 및 남미산 오징어 연골로부터 제조한 Chitosan의 레올로지 특성)

  • KIM Sang-Moo;PARK Seong-Min;CHOI Hyeon-Mee;LEE Keun-Tai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.5
    • /
    • pp.859-867
    • /
    • 1997
  • In order to utilize the processing wastes of squid, chitosans were manufactured from the pens of domestic squid, Todarbdes pacificus and foreign squid, Ommastrephes bartrami and then, its rheological properties were studied. The amounts of nitrogen and minerals of the domestic squid pens were $11.4\%\;and\;0.1\%$ respectively, whereas those of its chitosan were $7.5\%\;and\;0.2\%$. In case of foreign squid pen and chitosan, the amounts of nitrogen and minerals were $12.1\%,\;0.8\%\;and\;7.8\%,\;0.2\%$ respectively. Intrinsic viscosity $([\eta]) $ of domestic and foreign squid pen chitosans were decreased with increasing pH from 3.4 to 5.4 which might be due to the reduced repulsion in inter- of intra- chitosan molecules. Intrinsic viscosity of the domestic and foreign squid pen chitosans were decreased with increasing NaCl concentration thus indicated that the domestic and foreign squid pen chitosans were polyelectrolyte molecules and stiffness of squid pen thitosans were 0.11 similar to that of k-carrageenan. Flow type of squid pen chitosan solutions were pseudoplastic fluids without yield stress by the viscosity measurement. But the squid pen chitosan solutions showed newtonian fluid up to $0.15\~0.24\%$ concentration for domestic and $0.21\~0.24\%$ concentration for foreign at $10\~50\%$. Concentration dependence of consistency index in infinitive dilute domain (Kc) were higher in the dilute domain than entangled domain. Activation energies (Ea) of the squid pen chitosans were 3.7, 6.3, 3.6, 4.0 and 4.1 Kcal/g moi for domestic and 3.2, 3.1, 3.4, 3.8 and 3.6 Kcal/g mol for foreign at 0.1, 0.15, 0.25, 0.35 and $0.5\%$, respectively.

  • PDF

Ultrasound Measurement of Coracohumeral Distance in Patients with or without Subcoracoid Impingement (오구돌기하 충돌 증후군 유무에 따른 초음파를 이용한 상완오구돌기 계측)

  • Jang, Suk Hwan;Kim, Sang Bum
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate coracohumeral distance (CHD) in patients with or without subcoracoid impingement with hypothesis that patients with subcoracoid impingement would have narrower CHD. Materials and Methods: One hundred twenty-four patients with subacromial impingement were evaluated. The subjects with subcoracoid impingement which was affirmed clinically and confirmed by ultrasound guided subcoracoid injection (n=28) was compared with patients with subacromial impingement only (n=96). Patients with stiffness and rotator cuff tear were excluded. Absolute CHD was measured on magnetic resonance imaging (MRI) axial images and on ultrasound with the humerus in neutral position and internal rotation. Also relative ratio of distance difference (RRDD) defined as the difference of CHD in neutral position and internal rotation compared with absolute CHD in neutral on ultrasound was also measured. Results: The distance measured in neutral position was similar between US imaging and MRI (p>0.05) and both measurements did not have significant difference between the two groups (p>0.05). On ultrasound, the difference in CHD in internal rotation between the two groups nearly met the level of significance (p=0.07). No significant difference of CHD difference in two humeral positions was seen between the two groups. However, RRDD value was significantly greater in subcoracoid impingement group (p<0.05). Conclusion: No significant difference of CHD was seen between the subcoracoid impingement group and the control group. RRDD value was greater in subcoracoid impingement group suggesting that individualized coracohumeral distance in internal rotation should be taken into account when assessing patients with subcoracoid impingement.

  • PDF