• 제목/요약/키워드: Measurement of Step Difference

검색결과 111건 처리시간 0.023초

Effect of Forest Road Types on Salivary Cortisol, Blood Lactate and Heart Rate during Walking Exercise

  • JaeHeon Son;Junwon Min;KiHong Kim
    • International journal of advanced smart convergence
    • /
    • 제12권4호
    • /
    • pp.386-394
    • /
    • 2023
  • This study investigated changes in salivary cortisol, lactic acid, and heart rate along the route during walking exercise in a forest environment for the purpose of reducing stress. Walking exercise in a forest environment was conducted on a Hill Type (Distance: 800m, Average slope 25°, Altitude 112m) and Step Type (Distance: 800m, Average slope 25°, Altitude 114m) routes for 10 female college students in their 20s. The subjects were asked to walk at a speed of 60 bpm. The resulting changes in salivary cortisol, lactate, and average heart rate during exercise were compared and analyzed using Repeated Measurement two-way ANOVA, and the maximum heart rate during exercise and average heart rate at rest were compared and analyzed using paired t-test, and the following results were obtained. First, there was no significant difference in salivary cortisol depending on the type and period of the forest, but it tended to gradually decrease. Second, there was a significant difference in lactic acid depending on the type and period, and it was higher in Step Type. Third, there was a significant difference in the average heart rate during exercise, and it was higher in Step Type. Fourth, there was a significant difference in maximum heart rate during exercise, and it was higher in Step Type. Fifth, there was no significant difference in average heart rate during rest. In summary, walking exercise in a forest environment can be effective for stress reduction for female college students in their 20s, but it appears that forest routes should be selected according to physical strength level, and walking exercise in a forest environment for long periods of time is not recommended. For this purpose, it is suggested that it is appropriate to select the Hill Type route.

The effect of gait training with an elastic ankle-foot orthosis on balance and walking ability of persons with chronic stroke: a randomized controlled trial

  • Chi, Ming Hao;Yim, Jong Eun;Yi, Dong hyun
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.222-229
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of treadmill exercise on the posture and walking speed of chronic stroke survivors with an ankle-foot orthosis. Design: Randomized controlled trial. Methods: Twenty-four chronic persons with chronic stroke admitted to Bobath Memorial Hospital in Seongnam city were divided into two groups by random blind method. Treadmill exercise with an elastic ankle-foot orthosis was performed in the experimental group and treadmill exercise was performed in the control group. The experiment was carried out for 6 weeks, and the experiment was carried out three times a week for 20 minutes per session. To measure the effect, static balance was measured using the MTD system before and after training, and the Berg Balance Scale (BBS) was used to measure functional balance. Results: There was a statistically significant difference between the 2 groups in the BBS measurement results for confirming the functional balance (p<0.05). Also, there was a significant difference between the 2 groups in single limb support time, step time and step length (p<0.05). Conclusions: In this study, it was found that treadmill exercise with an elastic ankle-foot orthosis in persons with chronic stroke was effective in maintaining functional balance, walking ability, step length, and step time. Therefore, it is necessary to use a flexible ankle-foot orthosis with proper treadmill exercise as a method of improving balance and walking speed of chronic stroke survivors.

Assessment of Gait Ability of Subjects With Chronic Ankle Instability During an Inter-trial Variability Gait Task According to Changes in Gait Speed

  • Jeonghan Kwon;Jongduk Choi
    • 한국전문물리치료학회지
    • /
    • 제30권4호
    • /
    • pp.268-274
    • /
    • 2023
  • Background: Ankle sprains occur frequently among humans who undertake various body movements. Diverse walking environments and dual tasks, that can affect ankle sprains, have been studied. However, there is a lack of research on inter-trial variability according to the changes in gait speed. Objects: The purpose of this study was to compare the adaptive ability of walking between the subjects with chronic ankle instability and healthy adults while performing a walking task with different walking speeds. Methods: In this study, 24 people in the chronic ankle instability group and 24 people in the healthy ankle group were selected as subjects. The length of the pre-measurement and the actual walking measurement were both set to 4.6 m. Once the subjects entered the measurement section, they changed their gait speed according to the randomly assigned speed change. Gait was measured twice and the average value was used for the analysis. Results: The coefficient of variation (CV) of cycle time in subjects with chronic ankle instability showed a significant difference in all cases except when the subjects changed their speed from preferred to slow and from slow to preferred. The CV of step length demonstrated a significant difference in all cases except for the change from slow to preferred and from preferred to fast. The cycle time and step length differential showed a significant difference only when the subjects changed the speed from slow to fast. Conclusion: The subjects with chronic ankle instability were found to have significantly reduced walking adaptability while performing inter-trial variability tasks with different gait speeds compared to healthy subjects.

Walking Patterns According to the Room of Shoes Sizes - Focusing on Female Collegians on Busan -

  • Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제8권6호
    • /
    • pp.78-89
    • /
    • 2004
  • With 100 collegians residing in Busan, a shoes wearing survey was held. Out of the subjects, 50 women collegians showing some interest in fashion sneakers were chosen to reveal the effects of shoes size changes on walking patterns and wearing sense. This study focused on the fitness of sneakers produced the following results: 1. Survey Results of Shoes Wearing The subjects had some room in wearing sneakers or athletic shoes, including $20{\sim}30mm$ (33%). Just 25% of the subjects reported about the experience of falling, and 67.6% had difficulty walking on downhills. 50% felt feet fatigue difference when wearing fitting and unfitting shoes. 2. Analysis of Walking Patterns & Survey Results of Wearing Sense No significance was found among shoes sizes in left and right step angles. Step width measurement revealed no significance among shoes sizes. Significance ($p{\le}.05$) existed among shoes sizes in steps and strides. Significance ($p{\le}.001$) was noticed among shoes sizes in wearing sense.

스포츠윤리교육 프로그램의 교육만족도 측정도구 개발 (The Development of a Measurement Tool for Educational Satisfaction of Sport Ethics Program)

  • 최유리
    • 디지털융복합연구
    • /
    • 제16권8호
    • /
    • pp.381-391
    • /
    • 2018
  • 이 연구는 스포츠윤리교육 프로그램에 대한 교육만족도 측정도구를 개발하고 그 타당성을 검증하는 데 목적이 있다. 연구의 목적을 달성하기 위하여 연구절차는 다음과 같이 3단계로 이루어졌다. 1단계에서는 스포츠윤리교육 프로그램과 관련된 선행연구를 분석하고, 개방형 질문지를 통해 얻어진 응답 결과를 토대로 예비문항을 구성하였다. 2단계는 예비조사단계로서 1단계에서 진행된 측정도구의 탐색적 요인분석과 확인적 요인분석을 통해 구인타당성을 확보하였다. 3단계는 본 조사 단계로서 차이 검증을 통해 측정도구의 외적타당도를 확보하였으며, 이를 통해 도출된 내용을 중심으로 교육만족도측정을 위한 문항을 구성하였다. 그 결과 교육내용 6문항, 강사역량 5문항, 교육효과 6문항, 총 3개 영역 17개 문항으로 스포츠윤리교육 프로그램의 교육만족도 측정도구가 개발되었다. 이 연구는 실효성 있는 스포츠윤리교육 프로그램 개발을 위한 기초자료로 활용될 수 있으며, 이를 통해 윤리적인 소양을 지닌 스포츠선수로 성장할 수 있는 기반이 마련됨으로써 궁극적으로 스포츠계의 변화와 발전에 기여할 수 있기를 기대한다.

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

백색광 주사 간섭계의 측정 속도 개선을 위한 서브 샘플링 기법 연구 (Sub-sampling Technique to Improve the Measurement Speed of White Light Scanning Interferometry)

  • 천인범;주기남
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.999-1006
    • /
    • 2014
  • In this investigation, we explain the sub-sampling technique of white light scanning interferometry (WLSI) to improve the measurement speed. In addition to the previous work using Fourier domain analysis, several methods to extract the height from the correlogram of WLSI are described with the sub-sampling technique. Especially, Fourier-inverse Fourier transformation method adopting sub-sampling technique is proposed and the phase compensation technique is verified with simulation and experiments. The main advantage of sub-sampling is to speed up the measurements of WLSI but the precision such as repeatability is slightly poor. In case of measuring the sample which has high height step or difference, the proposed technique can be widely used to reduce the measurement time.

Two Step on-axis Digital Holography Using Dual-channel Mach-Zehnder Interferometer and Matched Filter Algorithm

  • Lee, Hyung-Chul;Kim, Soo-Hyun;Kim, Dae-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.363-367
    • /
    • 2010
  • A new two step on-axis digital holography (DH) is proposed without any assumptions, phase shifting, or complicated optical components. A dual-channel Mach-Zehnder interferometer was employed. Using that setup, the object field can be reconstructed requiring only two step measurements. To eliminate position difference between two charge-coupled device (CCD) cameras, a matched filter algorithm was used. Experimental results are compared to those of the traditional phase shifting technique. The proposed approach can also be applied to single-exposure on-axis DH for real time measurement.

제조부문과 사무간접/서비스부문의 6시그마 프로세스 개선활동 비교분석 (A Comparative Analysis between Manufacturing and Transactional/Service Processes of Six Sigma Quality Improvement)

  • 윤재욱;김보형
    • 품질경영학회지
    • /
    • 제36권4호
    • /
    • pp.37-46
    • /
    • 2008
  • There are big differences in six sigma projects between manufacturing processes and transactional/service processes. This paper analyzed the differences between the two areas by examining 18 six sigma case studies in Korean companies. To characterize six sigma case studies, step-by-step questions and check criteria were developed based on 12 step DMAIC methodology. On the basis of those characterized data, the differences between two areas were analyzed. Significant differences were found in the number of CTQs, validation of measurement systems, methods to determine improvement objectives, the methods to elicit improvement plans and types of control systems. The most significant difference was that statistical tools were widely used in manufacturing processes, but qualitative tools were used in transactional/service processes during improvement phase.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.