• Title/Summary/Keyword: Measurement locations

Search Result 582, Processing Time 0.027 seconds

Linear interrogation of fiber Bragg grating sensor array using a Etalon filter (에탈론 필터를 이용한 광섬유격자 센서의 선형 복조)

  • Jin, Zhong-Xie;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.74-77
    • /
    • 2006
  • A scanned Fabry-Perot(F-P) filter and a Multi-Channel Wavelength Locker(MCWL) were used to interrogate fiber Bragg grating sensor array. When the F-P filter scans over the MCWL which works as a multi-reference the temporal peaks profiles correspond to the locking wavelengths. To solve the linearity, stability, and accuracy problems caused by the nonlinear response of F-P filter, a polynomial fitting algerian was used to calculate the relationship between the peak locations and the wavelengths in all the scanning range. Then from the reflected peaks locations and the best fitting line, the Bragg wavelengths can be obtained. The measurement linearity was greatly enhanced with wavelength resolution of about 4 pm in 10Hz scanning frequency.

  • PDF

Chest Wall Thickness Measurement of the LLNL Phantom for Ce Detectors (Ce 검출기를위한 LLNL 팬텀의가슴벽두께측정)

  • Lee, Tae-Young;Lee, Jong-Il;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.3-9
    • /
    • 2000
  • The Korea Atomic Energy Research Institute acquired the Lawrence Livermore National Laboratory phantom for calibration of germanium detectors used for in vivo measurement of radionuclides deposited in human lungs. The manufacturer inscribed concentric circles as a phoswich detector positioning guides on the phantom's torso plate and its overlay plates, and provided the effective thickness of the chest wall for each plate measured at locations over the circles. However, since the germanium detectors are of different sizes, the areas considered for phoswich detectors were no. longer applicable for the locations of the germanium detectors on the phantom. Therefore, we re-evaluated the effective thickness of the phantom to determine if the manufacturer' s data are valid for germanium detectors in use for in vivo lung counting or if new values must be implemented. Differences no more than 3% in effective thickness were found between the germanium detector regions to be used at the Korea Atomic Energy Research Institute and the phoswich detector regions prescribed by the manufacturer.

  • PDF

Visual Precise Measurement of Pile Rebound and Penetration Movement Using a High-Speed Line-Scan Camera

  • Lim, Mee-Seub;You, Bum-Jae;Oh, Sang-Rok;Han, Song-Soo;Lee, Sang-Hun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.341-346
    • /
    • 2002
  • When a construction company builds a high structure. many piles should be driven into the ground by a hammer whose weight is 7,000 kg in order to make the ground under the structure safe and strong. So. it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously. Especially- by adopting a line-scan CCD camera whose line rate is 20 ㎑. the measurement performance of dynamic characteristics of the pile at impact instant is improved dramatically.

Temperature and Pressure Measurement on the Flame Deflector during KSLV-I Flight Tests (나로호 비행시험을 통한 화염유도로의 온도 및 압력 측정)

  • Jung, Il-Hyung;Moon, Kyung-Rok;Kang, Sun-Il;An, Jae-Chel;Ra, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.4
    • /
    • pp.378-384
    • /
    • 2011
  • During the flight test of KSLV-I, various sensors are installed in the launch pad and the flame deflector to measure the flame characteristics and their influences on the launch complex when a launch vehicle lifts off. Parameter Measurement System is responsible for acquiring the above flight test data. The measurement methodology such as the configuration of measurement system, sensor locations and data acquisition procedures are presented. And this paper compares and explains the characteristics of data sets measured during two flight tests.

Development of Profilometry based on a Curvature Measurement (곡률에 근거한 형상 측정기술 개발)

  • Kim, Byoung-Chang
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.130-134
    • /
    • 2007
  • I present a novel curvature profilometer devised fur the profile measurement of aspheric and free-form surfaces on the nanometer scale. A profile is reconstructed from measuring the curvature of a test part of the surface at several locations along a line. For profile measurement of free-farm surfaces, methods based on local part curvature sensing have strong appeal. Unlike full-aperture interferometry they do not require customized null optics. The measurement accuracy of the curvature profilometer was assessed by comparison with a well-calibrated interferometer in NIST. Experimental results prove that the maximum discrepancy turns out to be 37 nm on the 28 mm measurement range for the spherical mirror.

A study on the DGPS data errors correction through real-time coordinates conversion using the vision system (비젼 시스템을 이용한 DGPS 데이터 보정에 관한 연구)

  • Mun, Seong-Ryong;Chae, Jung-Su;Park, Jang-Hun;Lee, Ho-Soon;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2310-2312
    • /
    • 2003
  • This paper describes a navigation system for an autonomous vehicle in outdoor environments. The vehicle uses vision system to detect coordinates and DGPS information to determine the vehicles initial position and orientation. The vision system detects coordinates in the environment by referring to an environment model. As the vehicle moves, it estimates its position by conventional DGPS data, and matches up the coordinates with the environment model in order to reduce the error in the vehicles position estimate. The vehicles initial position and orientation are calculated from the coordinate values of the first and second locations, which are acquired by DGPS. Subsequent orientations and positions are derived. Experimental results in real environments have showed the effectiveness of our proposed navigation methods and real-time methods.

  • PDF

Example of Air Exposure Assessment for Fire Extinguishing Agent Residues (소화약제 잔류물질에 대한 공기 중 노출평가 사례)

  • Daesung Lim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.14-17
    • /
    • 2024
  • Objectives: This is a case of air exposure assessment conducted after researchers complained of headaches and odor due to residual substances from fire extinguishing agents spread throughout the laboratory due to a malfunction of the fire extinguishing facility. Methods: A component analysis was conducted on the residual substances of a fire extinguishing agent spread in a laboratory using Py-GC-MS (pyrolysis gas chromatography mass spectrometry) at the research institute's own central equipment research center. As a result of the component analysis, several types of substances were detected. Among these, five types of substances subject to work environment measurement in the aromatic hydrocarbon series, which can affect headaches and odor, were selected as substances subject to exposure assessment in the air, and the measurement and analysis methods of the target substances were conducted in accordance with the KOSHA Guide for each substance. Conclusions: The measurement results showed that all 5 types of substances were not detected at locations A, B, and C. This is believed to be the result of the residual substances in the fire extinguishing agent being measured when approximately two months had elapsed after being exposed to the test bench, and the substances already exposed had volatilized and disappeared. In this survey, it is believed that the measurement process is more important than the measurement results.

Temperature Distributions of the Lumbar Intervertebral Disc during Laser Annuloplasty : A Cadaveric Study

  • Lee, Min Hyung;Kim, Il Sup;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.559-563
    • /
    • 2016
  • Objective : Low back pain, caused intervertebral disc degeneration has been treated by thermal annuloplasty procedure, which is a non-surgical treatement. The theoretical backgrounds of the annuloplasty are thermal destruct of nociceptor and denaturization of collagen fiber to induce contraction, to shrink annulus and thus enhancing stability. This study is about temperature and its distribution during thermal annuloplasty using 1414 nm Nd : YAG laser. Methods : Thermal annuloplasty was performed on fresh human cadaveric lumbar spine with 20 intact intervertebral discs in a $37^{\circ}C$ circulating water bath using newly developed 1414 nm Nd : YAG laser. Five thermocouples were attached to different locations on the disc, and at the same time, temperature during annuloplasty was measured and analyzed. Results : Thermal probe's temperature was higher in locations closer to laser fiber tip and on lateral locations, rather than the in depth locations. In accordance with the laser fiber tip and the depth, temperatures above $45.0^{\circ}C$ was measured in 3.0 mm depth which trigger nociceptive ablation in 16 levels (80%), in accordance with the laser fiber end tip and laterality, every measurement had above $45.0^{\circ}C$, and also was measured temperature over $60.0^{\circ}C$, which can trigger collagen denaturation at 16 levels (80%). Conclusion : When thermal annuloplasty is needed in a selective lesion, annuloplasty using a 1414 nm Nd : YAG laser can be one of the treatment options.

Measurement of the Time Taken for Initial Water Discharge According to the Number of Kinks in the Fire Hose of the Indoor Hydrant System

  • Hong, Suk-Hwan;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.360-366
    • /
    • 2021
  • In this study, we tried to examine how the kinking of the fire hose affects the time taken for initial water discharge by measuring and analyzing the time taken for initial water discharge with different number of kinks at different locations of the hose. The average time taken for initial water discharge was obtained by measuring the time in the unkinked state of the fire hose. Based on this standard, we conducted the experiment by selecting the kinking locations in the hose near the water outlet and nozzle, and setting the number of kinks to 3, 6, 9, and 12. The results of this study are as follows: First, if the fire hose has 5 kinks or more near the nozzle, no water was released. Second, when comparing the case of no kinks and 4 kinks near the nozzle, there was no significant difference in the time taken for initial water discharge. Third, when the fire hose was kinked 10 times near the outlet, the time required for initial water discharge increased by 1.62 seconds on average compared to the case with no kinking, but there was no problem with water discharge. Lastly, regarding the kinking locations of the fire hose, it was found that the greater the number of kinks near the nozzle than near the outlet, the greater the effect on the discharge. As a result, it is concluded that it would be preferable to install non-kinking devices near the nozzle of the fire hose.

A Measurement of the Exposure Rates by Terrestrial y-rays in Taegu Area (대구지역(大邱地域) 지각(地殼) ${\gamma}$-선(線)의 조사선량율(照射線量率) 측정(測定))

  • Chang, Si-Ho;Jeong, Chun-Gyun;Kang, Hee-Dong;Lee, Mo-Sung;Choi, Mun-Kyu;Kim, Wi-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.121-132
    • /
    • 1994
  • This study concerns about the measurement and the investigation of environmental radiation characteristics which the components and the distribution of exposure rates by terrestrial y-rays in Taegu area. $4^{'}{\phi}{\times}4^{'}$ NaI(T1) scintillation detector with a multichannel analyzer was used in the measurement of y-rays as a part of in-situ spectrometry at twenty eight different locations in this area. The conversion into the exposure rate from the measured ${\gamma}-ray$ spectrum has been carried out leading to a net exposure rate and component ones by $^{40}K,\;^{238}U$ series and $^{232}Th$ series products which are known by the major parts in the terrestrial ${\gamma}-rays$ generally. As a result, the average exposure rate by the terrestrial ${\gamma}-rays$ in Taegu area is $9.4{\mu}R/h$ and the distribution of individual exposure rates shows more or less differences between these locations even after the consideration of diurnal and yearly variations which are always involved in these measurements. The component parts of exposure rates are distributed $^{40}K\;2.9{\sim}4.6{\mu}R/h,\;^{238}U$ series $1.2{\sim}3,\;1{\mu}R/h,\;^{232}Th$ series $2.5{\sim}5.0{\mu}R/h$ over the measured locations.

  • PDF