• 제목/요약/키워드: Measurement and verification

검색결과 924건 처리시간 0.036초

산림부문의 국가온실가스 배출·흡수계수 개발 필요 우선순위 및 정량평가 방법론 (Priority for Developing Emission Factors and Quantitative Assessment in the Forestry Sector)

  • 한승현;이선정;장한나;김성준;김래현;전의찬;손요환
    • 한국기후변화학회지
    • /
    • 제8권3호
    • /
    • pp.239-245
    • /
    • 2017
  • This study aimed to suggest priority for developing emission factor (EF) and to develop the methodology of quantitative assessment of EF in the forestry sector. Based on the stock-difference method, 17 kinds of EFs (27 EFs based on forest types) were required to calculate the carbon emission in the forestry sector. Priority for developing EFs followed the standards, which is a development plan by the government agency, importance of carbon stock for greenhouse gas, and EFs by the species. Currently, the most urgent development of EFs was carbon fraction in biomass and carbon stock in dead wood. Meanwhile, the quantitative assessment of EF consisted of 7 categories (5 categories of compulsory and 2 categories of quality evaluation) and 12 verification factors. Category in compulsory verification consisted of administrative document, determination methodology of emission factors, emission characteristic, accuracy of measurement and analysis, and data representative. Category in quality evaluation consisted of data management and uncertainty estimates. Based on the importance of factors in the verification process, each factor was scored separately, however, the score needs to be coordinated by the government agency. These results would help build a reliable and accurate greenhouse gas inventory report of Korea.

임상보고 가능범위의 실증적 연구 (An Empirical Study of the Clinically Reportable Range in Clinical Chemistry)

  • 장상우;이상곤;최호성;송은영;박용원;이인애
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

KSLV-I 킥모터 개발을 위한 고공환경모사시험용 추력측정장치 (Thrust Measurement System for High Altitude Simulation Test of the KSLV-I Kick Motor)

  • 이정호;조상연;조기주;정동호;이한주;오승협;윤경렬;김동철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.428-431
    • /
    • 2008
  • Korea Aerospace Research Institute(KARI) is achieving the Korea Space Launch Vehicle(KSLV) program according to National Space Technology Development Program. KSLV-I will be composed to liquid propellant(first stage) and solid propellant(second stage) propulsion system. The propulsion system of KSLV-I second stage is solid kick motor with high expansion ratio and its starting altitude is 300km high. In order to verify the performance of upper stage propulsion system designed to operate in the upper atmosphere, test facility which can simulate high altitude is needed. High Altitude Simulation Test Facility is composed to Thrust Measurement System, Control & Measurement system, Diffuser, SKID for cooling water supply to diffuser, CCTV, fire protection system and so on. This paper introduces TMS adapted to High Altitude Simulation Test for KSLV-I Kick Motor Development and results of hot firing test for its performance verification.

  • PDF

SAR 위성의 고주파 호환성 설계 및 검증 (RF Compatibility Design & Verification for the SAR Satellite)

  • 원영진;박홍원;문홍열;우성현;김진희
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.37-48
    • /
    • 2011
  • 영상 레이더(SAR)는 날씨나 밤낮에 관계없이 전천후로 고해상도의 지구 관측을 가능하게 하는 강력하고 잘 정립된 마이크로웨이브 원격 탐사 기술이다. 한국항공우주연구원에서는 올해 발사될 예정인 우리나라 최초의 영상 레이더 위성을 개발해오고 있다. 영상 레이더 위성은 크게 위성 본체와 SAR 탑재체로 이루어진다. SAR 탑재체는 고출력의 전력을 SAR 안테나를 통하여 방사하기 때문에 설계 단계에서의 고주파 호환성 있는 설계와 시험단계에서의 고주파 호환성 검증이 실제 궤도 상에서 성능 보장을 위해서 무엇보다 중요한 절차이다. 본 연구에서는 영상 레이더 위성의 고주파 호환성을 위한 설계 기준과 검증 절차에 대하여 기술한다. 부가적으로 본 논문은 영상 레이더 위성의 RF 성능의 강건성 검증을 위한 RF 전체 방사 시험(RF 자체 호환성 시험)과 시험 형상 그리고 시험 결과에 대하여 기술한다.

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

  • Moon, Sun Young;Jeong, EunHee;Lim, Young Kyung;Chung, Weon Kyu;Huh, Hyun Do;Kim, Dong Wook;Yoon, Myonggeun
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.213-219
    • /
    • 2016
  • The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this method is encumbered by the lengthy time interval required from film scanning to analysis, which makes real-time position verification difficult. In general, the source position accuracy is usually tested in a monthly quality assurance check. In this context, this study investigates the feasibility of the real-time position verification of the radiation source in high dose rate (HDR) brachytherapy with the use of scintillating fibers. To this end, we construct a system consisting of scintillating fibers and a silicon photomultiplier (SiPM), optimize the dosimetric software setup and radiation system characteristics to obtain maximum measurement accuracy, and determine the relative ratio of the measured signals dependent upon the position of the scintillating fiber. According to the dosimetric results based on a treatment plan, in which the dwell time is set at 30 and 60 s at two dwell positions, the number of signals is 31.5 and 83, respectively. In other words, the signal rate roughly doubles in proportion to the dwell time. The source position can also be confirmed at the same time. With further improvements in the spatial resolution and scintillating fiber array, the source position can be verified in real-time in clinical settings with the use of a scintillating fiber-based system.

IPTV 서비스 품질의 사전 관리를 위한 서비스 이용자 중심의 상시 측정 방안 구현과 검증 (Implementation and Verification of User Centric Constant Measurement for Pre-management of IPTV Service Quality)

  • 김범준;김진철;박재성
    • 정보처리학회논문지C
    • /
    • 제18C권1호
    • /
    • pp.23-30
    • /
    • 2011
  • 최근 네트워크의 광대역화에 따라 새로 등장한 대표적인 서비스로 IPTV(Internet Protocol Television) 서비스를 들 수 있다. 서비스 품질(Quality of Service; QoS)이 보장되지 못하는 인터넷을 통한 IPTV 서비스가 성공적으로 정착하여 활성화되기 위해서는 철저한 서비스 품질 관리가 필수적이다. 이를 위해서는 기존의 계측기에 의한 서비스 품질의 사후 관리는 향후 서비스 이용자가 서비스를 받는 중 이루어지는 실시간 측정 위주의 서비스 품질 관리로 바뀌어야 할 필요가 있다. 따라서 본 논문에서는 서비스 이용자 위주의 상시 품질 측정이 가능한 IPTV 서비스 품질 관리 방안을 제안한다. 제안된 방안의 구현을 위해 개발된 소프트웨어는 서비스 이용자 측의 셋톱박스에 설치되어 실시간으로 IPTV 서비스의 품질을 상시 측정하고 이를 보고할 수 있는 기능을 갖추고 있다. 구현된 소프트웨어의 신뢰성을 검증하기 위하여 다수 개의 중요 지표들에 대해서 대표적인 두 개의 상용 계측기와 비교하였고 그 결과 개발된 소프트웨어를 통한 측정 결과가 사용 계측기와 크게 다르지 않고 신뢰할 수 있음을 보였다.

광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정 (Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs))

  • 임인철;유윤식;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.86-92
    • /
    • 2011
  • 본 연구는 최근 생체내선량측정에서 유용성을 재평가 받고 있는 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)와 다이오드 검출기를 병행하여 직장암 방사선치료 환자의 피부선량을 측정하고 치료계획시스템 에서 계산 선량과 측정 선량을 비교하여 OSL 선량계의 임상적 유용성을 평가하고자 하였다. 각 OSL 선량계의 고유한 교정상수를 측정하고 10 명의 직장암 환자를 대상으로 3 부위를 설정하여 측정하였다. 기준 흡수선량 100 cGy에 대하여 OSL 선량계의 교정상수는 6 MV X-선의 경우 1.17, 10 MV X-선의 경우 1.28 이었다. 또한 직장암 환자들의 피부선량은 측정 부위별로 치료계획시스템에서 계산 선량과 비교하여 다이오드 검출기는 1.16 ~ 2.83%의 선량증가를 보였고 OSL 선량계는 1.36 ~ 2.17%의 선량증가를 보였다. 특히 피부면의 굴곡이 심한 회음부(perineum)에서 계산된 선량과 전달 선량간 차이가 증가되었으며 다이오드 검출기보다 OSL 선량계가 측정값의 변화가 상대적으로 작았다. 따라서 OSL 선량계는 기존에 사용하던 이온함 및 다이오드 검출기를 대신하여 방사선량학적 오차의 검증 및 생체내선량측정에서 임상적으로 적용이 가능하였으며 직장암 환자의 굴곡이 심한 회음부 주변의 선량 평가에 대한 연구가 계속되어야 할 것으로 판단된다.

3차원 자유곡면을 갖는 금형의 초기및 수정가공을 위한 컴퓨터 이용기술 (Computer application techniques of initial and modification machining for dies with 3-Dimensional scluptured surfaces)

  • 박정현;손주리;박삼진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.273-278
    • /
    • 1988
  • This paper represents the computer application techniques of initial and modification machining for dies with 3-dimensional scluptured surfaces. All procedures from die design to die machining and measurement are covered. The component of modelling is data management and modification (extrapolation and smoothing), surface modelling, and nc program preparation. Also this paper introduces the utility for successful and efficient operation of system such as map generation, data communication, tool path verification, contour map generation, graphic processing of extrapolation and smoothing results, and CAD/CAM system interface. Examples are given to illustrate the modelling.

  • PDF

저추력 액체로켓엔진의 추력 측정 장치에 대한 연구 (The Study on the Thrust Measurement System of Low Thrust Liquid Rocket Engine)

  • 이동형;이양석;고영성;김유;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.55-59
    • /
    • 2008
  • 액체로켓엔진의 성능 검증에 있어서 가장 큰 비중을 차지하는 것 중 하나는 정확한 추력 측정이다. 본 연구에서는 기존의 추력 측정 장치를 보완한 저추력 액체로켓엔진의 추력 측정 장치를 개발하여 작은 추력을 발생하는 로켓엔진의 보다 정확한 추력 측정을 가능하도록 하였다. 또한, 추력 측정 장치의 추력 측정 평가 시 고려되는 주요 인자들에 대한 연구를 수행하여 추력 측정 장치의 신뢰도 평가에 관한 기법 및 절차 수립의 기반을 마련하였다.

  • PDF

광파측거의의 기계정수에 관한 연구 (A Study on Mechanism Stated Number of Electro-Optical Distance Measuring Instrument)

  • Lee, Y.H.;Mun, D.Y.
    • 한국항만학회지
    • /
    • 제5권2호
    • /
    • pp.77-84
    • /
    • 1991
  • This paper is compared with fourier series and least square polynomial fit and interpolation to mechanism stated number in electro-optical distance measuring instrument. Systematic instrumental errors occurring in electro-optical systems include uncertainties in the position of the electrical center of the transmitter, uncertainties in the effective center of the reflectors. frequency drift and instrument nonlinearity. Microwave systems are affected by uncertainties in the electrical centers of the master and remote units and by a phenomenon called group swing or reflection. As the result of this study, mechanism stated number will be used as verification of electro0optical measuring instrument to distance measurement.

  • PDF