• Title/Summary/Keyword: Measurement accuracy

Search Result 4,008, Processing Time 0.036 seconds

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Diagnostic Value of Cyfra 21-1 in Differential Diagnosis of Pleural Effusion (흉수의 감별 전단으로 Cyfra 21-1의 진단적 가치)

  • Lee, Hak-Jun;Lee, Kwan-Ho;Shin, Kyeong-Cheol;Shin, Chang-Jin;Park, Hye-Jung;Mun, Yeung-Chul;Lee, Kyung-Hee;Chung, Jin-Hong;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.50-56
    • /
    • 1999
  • Background : Pleural effusion is a common clinical problem and many clinical and laboratory evaluations, such as tumor marks, have been studied to discriminate malignant pleural fluid from benign pleural fluid. However their usefulness in the diagnosis of pleural effusion is still not established fully. We studied the diagnostic value of cyfra 21-1 in diagnosis of malignant pleural effusion. Methods: Pleural fluid was obtained from 45 patients with malignant diseases(32 lung cancer patients, 13 metastatic malignant diseases) and 47 patients with benign diseases. The level of cyfra 21-1 in the pleural fluid and serum were determined using a CYFRA 21-1 enzyme immunoassay kit(Cis-Bio International Co.). The t-test was used for comparison between two diseases groups and receiver operating characteristic(ROC) curves were constructed by calculating the sensitivities and specificities of the cyfra 21-1 at several points to determine the diagnostic accuracy of the cyfra 21-1. Results: In patients with primary lung cancer, the level of cyfra 21-1 in the pleural fluid was significantly higher than those of patients with benign diseases and had positive correlations between the level of cyfra 21-1 in the pleural fluid and serum levels. In the ROC curve analysis of the pleural fluid, the curve for primary lung cancer group was located closer to the left upper comer and the cut off value, sensitivity and specificity of the cyfra 21-1 of the primary lung cancer group was determined as 22.25ng/ml, 81.8% and 78.7% respectively. Conclusions: Our data indicates that the measurement of cyfra 21-1 level in pleural effusion has useful diagnostic value to discriminate malignant pleural effusion in primary lung cancer from benign pleural effusion.

  • PDF

A Study on Relationships Between Environment, Organizational Structure, and Organizational Effectiveness of Public Health Centers in Korea (보건소의 환경, 조직구조와 조직유효성과의 관계)

  • Yun, Soon-Nyoung
    • Research in Community and Public Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.5-33
    • /
    • 1995
  • The objective of the study are two-fold: one is to explore the relationship between environment, organizational structure, and organizational effectiveness of public health centers in Korea, and the other is to examine the validity of contingency theory for improving the organizational structure of public health care agencies, with special emphasis on public health nursing administration. Accordingly, the conceptual model of the study consisted of three different concepts: environment, organizational structure, and organizational effectiveness, which were built up from the contingency theory. Data were collected during the period from 1st of May through 30th of June, 1990. From the total of 249 health centers in the country, one hundred and five centers were sampled non proportionally, according to the geopolitical distribution. Out of 105, 73 health centers responded to mailed questionnaire. The health centers were the unit of the study, and a various statistical analysis techniques were used: Reliability analysis(Cronbach's Alpha) for 4 measurement tools; Shapiro-Wilk statistic for normality test of measured scores of 6 variables: ANOVA, Pearson Correlaion analysis, regressional analysis, and canonical correlation analysis for the test of the relationships and differences between the variables. The results were. as follows : 1. No significant differences between forma lization, decision-making authority and environmental complexity were found(F=1.383, P=.24 ; F=.801, P=.37). 2. Negative relationships between formalization and decision-making authority for both urban and rural health centers were found(r=-.470, P=.002 ; r=-.348, P=.46). 3. No significant relationship between formalization and job satisfaction for both urban and rural health centers were found (r=-.242, P=.132, r=-.060, P=.739). 4. Significant positive relationship between decision - making authority and job satisfaction were found in urban health centers (r=.504, P=.0009), but no such relationship was observed in rural health centers. Regression coefficient between them was statistically significant($\beta=1.535$, P=.0002), and accuracy of regression line was accepted (W=.975, P= .420). 5. No significant relationships among formalization and family planning services, maternal health services, and tuberculosis control services for both urban and rural health centers were found. 6. Among decision-making authority and family planning services, maternal health services, and tuberculosis control services, significant positive relationship was found between de cision-making authority and family planning services(r=.286, P=.73). 7. A significant difference was found in maternal health services by the type of health centers (F=5.13, P=.026) but no difference was found in tuberculosis control services by the type of health centers, formalization, and decision-making authority. 8. A significant positive relationships were found between family planning services and maternal health services and tuberculosis control services, and between maternal health services and tuberculosis control services (r=-.499, P=.001 ; r=.457, P=.004 ; r=.495, P=.002) in case of urban health centers. In case of rural health centers, relationships between family planning services and tuberculosis control services, and between maternal health services and tuberculosis control services were statistically significant (r=.534, P=.002 ; r=.389, P=.027). No significant relationship was found between family planning and maternal health services. 9. A significant positive canonical correlation was found between the group of independent variables consisted of formalization and de cision-making authority and the group of dependent variables consisted of family planning services, maternal health services and tuberculosis control services(Rc=.455, P=.02). In case of urban health centers, no significant canonical correlation was found between them, but significant canoncial correlation was found in rural health centers(Rc=.578, P=.069), 10. Relationships between job satisfaction and health care productivity was not found significant. Through these results, the assumed relationship between environment and organizational structure was not supported in health centers. Therefore, the relationship between the organizational effectiveness and the congruence between environment and organizational structure that contingency theory proposes to exist was not able to be tested. However decision-making authority was found as an important variable of organizational structure affecting family planning services and job satisfaction in urban health centers. Thus it was suggested that decentralized decision making among health professionals would be a valuable strategy for improvement of organizational effectiveness in public health centers. It is also recommended that further studies to test contingency theory would use variability and uncertainty to define environment of public health centers instead of complexity.

  • PDF

Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy (폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가)

  • Jang, Hyeong Jun;Lee, Yeong Gyu;Kim, Yeong Jae;Park, Yeong Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • Purpose : This study will evaluate the clinical utility by applying clinical schematic that uses monoenergy or dual energy as according to the location of tumors to the stereotactic radiotherapy to compare the change in actual dose given to the real tumor and the dose that locates adjacent to the tumor. Materials and Methods : CT images from a total of 10 patients were obtained and the clinical planning were planned based on the volumetric modulated arc therapy on monoenergy and dual energy. To analyze the change factor in the tumor, Comformity Index(CI) and Homogeneity Index(HI) and maximum dose quantity were each calculated and comparing the dose distribution on normal tissues, $V_{10}$ and $V_5$, first ~ fourth ribs closest to the tumor ($1^{st}{\sim}4^{th}$ Rib), Spinal Cord, Esophagus and Trachea were selected. Also, in order to confirm the accuracy on which the planned dose distribution is really measured, the 2-dimensional ion chamber array was used to measure the dose distribution. Results : As of the tumor factor, CI and HI showed a number close to 1 when the two energies were used. As of the maximum dose, the front chest wall showed 2% and the dorsal tumor showed equivalent value. As of normal tissue, the front chest wall tumors were reduced by 4%, 5% when both energies were used in the adjacent rib and as of trachea, reduced by 11%, 17%. As of the dose in the lung, as of $V_{10}$, it reduced by 1.5%, $V_5$ by 1%. As of the rear chest wall, when both energies were used, the ribs adjacent to the tumors showed 6%, 1%, 4%, 12% reduction, and in the lung dose distribution, $V_{10}$ reduced by 3%, and $V_5$ reduced by 3.1%. The dose measurement in all energies were in accordance to the results of Gamma Index 3mm/3%. Conclusion : It is considered that rather than using monoenergy, utilizing double energy in the clinical setting can be more effectively applied to the superficial tumors.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

Usefulness of serum procalcitonin test for the diagnosis of upper urinary tract infection in children (소아 상부 요로감염의 진단을 위한 혈청 procalcitonin 검사의 유용성)

  • Kim, Dong Wook;Chung, Ju Young;Koo, Ja Wook;Kim, Sang Woo;Han, Tae Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.87-92
    • /
    • 2006
  • Purpose : It is difficult to make a distinction between lower urinary tract infection(UTI) and acute pyelonephritis(APN) during the acute phase of febrile UTI due to nonspecific clinical symptoms and laboratory findings, especially among young children. We measured the serum procalcitonin(PCT) in children with UTI to distinguish between acute pyelonephritis and lower UTI, and to determine the accuracy of PCT measurement compared with other inflammatory markers. Methods : Serum samples were taken from children who admitted with unexplained fever or were suspected of having UTI. 51 children(mean $12.2{\pm}11.4$ months) were enrolled in this study. Leukocyte counts, erythrocyte sedimentation rates(ESR) and C-reactive protein(CRP) were also measured. Renal parenchymal involvement was assessed by $^{99m}Tc$ DMSA scintigraphy in the first 7 days after admission. PCT was measured by immunoluminometric assay. Results : PCT values were significantly correlated with the presence of renal defects in children with UTI(n=16)($5.06{\pm}12.97{\mu}g/L$, P<0.05). However, PCT values were not significantly different between children with UTI without renal damage(n=18) and children without UTI(n=17). Using a cutoff of $0.5{\mu}g/L$ for PCT and 20 mm/hr for ESR, 20 mg/L for CRP, sensitivity and specificity in distinguishing between UTI with and without renal involvement were 81.3 percent and 88.9 percent for PCT 87.5 percent and 72.2 percent for ESR, and 87.5 percent and 55.6 percent for CRP, respectively. Positive and negative predictive values were 86.7 percent and 84.2 percent for PCT and 60.9 percent and 81.8 percent for CRP, respectively. Conclusion : In febrile UTI, PCT values were more specific than CRP, ESR and leukocyte count for the identification of patients who might develop renal defects.

Comparison of Three Different Helmet Bolus Device for Total Scalp Irradiation (Total Scalp의 방사선 치료 시 Helmet Bolus 제작방법에 관한 연구)

  • Song, Yong-Min;Kim, Jong-Sik;Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young;Park, Su-Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • Purpose: This study evaluated the usefulness of Helmet bolus device using Bolx-II, paraffin wax, solid thermoplastic material in total scalp irradiation. Materials and Methods: Using Rando phantom, we applied Bolx-II (Action Products, USA), paraffin wax (Densply, USA), solid thermoplastic material (Med-Tec, USA) on the whole scalp to make helmet bolus device. Computed tomography (GE, Ultra Light Speed16) images were acquired at 5 mm thickness. Then, we set up the optimum treatment plan and analyzed the variation in density of each bolus (Philips, Pinnacle). To evaluate the dose distribution, Dose-homogeneity index (DHI, $D_{90}/D_{10}$) and Conformity index (CI, $V_{95}/TV$) of Clinical Target Volume (CTV) using Dose-Volume Histogram (DVH) and $V_{20}$, $V_{30}$ of normal brain tissues. we assessed the efficiency of production process by measuring total time taken to produce. Thermoluminescent dosimeters (TLD) were used to verify the accuracy. Results: Density variation value of Bolx-II, paraffin wax, solid thermoplastic material turned out to be $0.952{\pm}0.13g/cm^3$, $0.842{\pm}0.17g/cm^3$, $0.908{\pm}0.24g/cm^3$, respectively. The DHI and CI of each helmet bolus device which used Bolx-II, paraffin wax, solid thermoplastic material were 0.89, 0.85, 0.77 and 0.86, 0.78, 0.74, respectively. The result of Bolx-II was the best. $V_{20}$ and $V_{30}$ of brain tissues were 11.50%, 10.80%, 10.07% and 7.62%, 7.40%, 7.31%, respectively. It took 30, 120, 90 minutes to produce. The measured TLD results were within ${\pm}7%$ of the planned values. Conclusion: The application of helmet bolus which used Bolx-II during total scalp irradiation not only improves homogeneity and conformity of Clinical Target Volume but also takes short time and the production method is simple. Thus, the helmet bolus which used Bolx-II is considered to be useful for the clinical trials.

  • PDF

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

Analysis of PM2.5 Distribution Contribution using GIS Spatial Interpolation - Focused on Changwon-si Urban Area - (GIS 공간내삽법을 활용한 PM2.5 분포 특성 분석 - 창원시 도시지역을 대상으로 -)

  • MUN, Han-Sol;SONG, Bong-Geun;SEO, Kyeong-Ho;KIM, Tae-Hyeung;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.2
    • /
    • pp.1-20
    • /
    • 2020
  • The purpose of this study was to analyze the distribution characteristics of spatial and temporal PM2.5 in urban areas of Changwon-si, and to identify the causes of PM2.5 by comparing the characteristics of land-use, and to suggest the direction of reduction measures. As the basic data, the every hour average from September 2017 to August 2018 of Airpro data, which has measurement points in kindergartens, elementary schools, and some middle and high schools in Changwon-si was used. Also, by using IDW method among spatial interpolation methods of GIS, monthly and time-slot distribution maps were constructed, and based on this, spatial and temporal PM2.5 distribution characteristics were confirmed. First, to verify the accuracy of the Airpro data, the correlation with AirKorea data managed by the Ministry of Environment was confirmed. As a result of the analysis, R2 was 0.75~0.86, showing a very high correlation and the data was judged that it was suitable for the study. In the monthly analysis, January was the highest year, and August was the lowest. As a result of analysis by time-slot, The clock-in time at 06-09 was the highest, and the activity time at 09-18 was the lowest. By administrative district, Sangnam-dong, Happo-dong, and Myeonggok-dong were the most severe regions of PM2.5 and Hoeseong-dong was the lowest. As a result of analyzing the land-use characteristics by administrative area, it was confirmed that the ratio of traffic area and commercial area is high in the serious area of PM2.5. In conclusion, the results of this study will be used as basic data to grasp the characteristics of PM2.5 distribution in Changwon-si. Also, it is thought that the severe regions and the direction of establishing reduction measures derived from this study can be used to prepare more effective policies than before.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF