• Title/Summary/Keyword: Measurement Noise

Search Result 3,221, Processing Time 0.027 seconds

Development of a Portable Digital Electrocardiograph(ECG) measurable with Gel-less Metal Electrodes (젤리스 금속 전극으로 측정가능한 휴대용 디지털 심전도계의 개발)

  • Nam, Young-Jin;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1903-1907
    • /
    • 2013
  • Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

A Design Verification for the EQM CBS Ka-band Payload System by EMC Test (EQM 통신방송위성 KA대역 탑재체 시스템의 EMC 시험을 통한 검증)

  • Lee,Ho-Jae;U,Hyeong-Je;Sin,Dong-Hwan;Park,Jong-Heung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.97-104
    • /
    • 2003
  • This paper addresses EMC test results for the EQM Communications & Broadcasting Satellite(CBS) Ka-band Payload System. The aim of the EMC test is to verify that the payload system has no effect on the other system and is not affected by the external field. The compliance of EMC system requirements was verified by the analysis and measurement of the emission level from the payload system. The variation of performance by noise injection was measured to inspect the susceptibility of the payload system. The analysis and test results also showed that the electromagnetic interference has no serious effect on the overall payload system performance. It is confirmed that the EQM CBS Ka-band payload system can be operable in the space environment from the EMC performance's viewpoint. It is also obtained that better performance can be acquired by improving waveguide design and integration method.

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • Kil, Hyun-Gwon
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 1997
  • An automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane vibration fields over structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

Studies on Voice Changes Associated with Alcohol Intake (음주에 따른 음성 변화에 대한 고찰)

  • Kim, Jung-Hyun;Yoon, Je-Hwan;Cho, Hyung-Ho;Cho, Yeon;Cho, Jae-Sik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • Background and Objectives : It has been pointed out that alcohol intake in human beings induces changes in voice register and maximum phonation time. These changes supposedly result from injection of the vibratory vocal folds. The purpose of this study was to clarify the voice changes associated with alcohol intake and the changes of laryngeal mucosa. Materials and Methods : The subjects included 29 volunteers, including 20 men and 9 women ranging in age from 22 to 31 years. Alcohol intake was accomplished by oral administration of 23% soju 1 bottle (255cc). Serum alcohol concentration levels were evaluated hourly for 3 h after ingestion of alcohol. Seven measurements were performed at pre-alcohol intake and post-alcohol intake hourly : fundamental frequency, jitter, shimmer, noise to harmonic ratio as the acoustic analysis, maximal phonation time, mean flow rate, and subglottal pressure as the aerodynamic analysis. The changes of laryngeal mucosa were evaluated by flexible laryngoscope at each measurement. Results : By comparing the acoustic and aerodynamic data and laryngeal mucosa before and after alcohol intake, there were not remarkable changes (p>0.05). Conclusion : The voice and laryngeal mucosa have not remarkably changed according to alcohol concentration in this study. Furthermore studies on the voice change induced by multiple alcohol concentrations are required.

  • PDF

Analysis of Vibration Transfer Characteristics of Approach Bridges for an Elevated Railroad Station (철도선하역사 접속교량의 진동전달 특성 분석)

  • Choi, Sanghyun;Kim, Jin-Ho;Yoo, Yong;Kwon, Se-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2911-2916
    • /
    • 2015
  • The elevated railway station, above which a train is passing, is vulnerable to noise and vibration compared to other station types. To better identify the vibration characteristics of the elevated railway station, the transferred vibration from approach bridges should be analyzed. In this paper, through experiments and simulations, the transfer characteristics of the vibration from approach bridges is analyzed. The study structure is Geomgok station and the anaylses are conducted using ABAQUS three dimensional numerical model. To identify the change in the transfer characteristics for various bearing types, the analyses are performed considering mechanical properties of bearing for railway bridges. The measurement is performed using the accelerometers attached to the approach bridges and the station structure along the passing path of trains.

Bluetooth Beacon Planing Considering Position Estimation Accuracy in Small and Isolated In-Door Environment (소형독립공간에서 실내측위 정확도를 고려한 블루투스 비컨 위치선정)

  • Ahn, Heejune;Thuy, Tran Vinh;Lee, Ye Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1307-1312
    • /
    • 2015
  • The recent adoption of Bluetooth LE technology in smart phones triggered commercial interest in RSSI-based positioning technology. Estimation error in RSSI measurement due to the antenna pattern, multipath fading, environmental noise has to be considered for designing beacon systems. The paper proposes an analysis method and beacon planning rules for a small and isolated indoor service area, based on probabilistic model of RSSI estimation error. As an practically important guide, the beacons have to be installed at the boundary of the service area to minimize the maximum position error, whereas the beacons have to be evenly distributed in the service space to minimize the average estimation error.

A "GAP-Model" based Framework for Online VVoIP QoE Measurement

  • Calyam, Prasad;Ekici, Eylem;Lee, Chang-Gun;Haffner, Mark;Howes, Nathan
    • Journal of Communications and Networks
    • /
    • v.9 no.4
    • /
    • pp.446-456
    • /
    • 2007
  • Increased access to broadband networks has led to a fast-growing demand for voice and video over IP(VVoIP) applications such as Internet telephony(VoIP), videoconferencing, and IP television(IPTV). For pro-active troubleshooting of VVoIP performance bottlenecks that manifest to end-users as performance impairments such as video frame freezing and voice dropouts, network operators cannot rely on actual end-users to report their subjective quality of experience(QoE). Hence, automated and objective techniques that provide real-time or online VVoIP QoE estimates are vital. Objective techniques developed to-date estimate VVoIP QoE by performing frame-to-frame peak-signal-to-noise ratio(PSNR) comparisons of the original video sequence and the reconstructed video sequence obtained from the sender-side and receiver-side, respectively. Since processing such video sequences is time consuming and computationally intensive, existing objective techniques cannot provide online VVoIP QoE. In this paper, we present a novel framework that can provide online estimates of VVoIP QoE on network paths without end-user involvement and without requiring any video sequences. The framework features the "GAP-model", which is an offline model of QoE expressed as a function of measurable network factors such as bandwidth, delay, jitter, and loss. Using the GAP-model, our online framework can produce VVoIP QoE estimates in terms of "Good", "Acceptable", or "Poor"(GAP) grades of perceptual quality solely from the online measured network conditions.

Path Metric Comparison-based Adaptive QRD-M Algorithm for MUHO Systems (Path Metric 비교 기반 적응형 QRD-M MIMO 검출 기법)

  • Kim, Bong-Seok;Kim, Han-Nah;Choi, Kwon-Hue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6C
    • /
    • pp.487-497
    • /
    • 2008
  • This paper proposes a new adaptive QRD-M algorithm for MIMO systems. The proposed scheme controls the number of survivor paths,0 based on the channel condition at each layer. The original QRD-M algorithm used fixed M at each layer and it needs large M to achieve near-MLD (maximum-likelihood detection) performance. However, using the large M increases the computation complexity. In this paper, we further effectively control M by employing the channel indicator which includes not only the channel gain, but also instantaneous noise information without necessity of SNR measurement. We found that the ratio of the minimum path metric to the second minimum is good reliability indicator for the channel condition. By adaptively changing M based on this ratio, the proposed scheme effectively achieves near MLD performance and computation complexity of the proposed scheme is significantly smaller than the conventional QRD-M algorithms.