• Title/Summary/Keyword: Mean drop size

Search Result 86, Processing Time 0.028 seconds

In-cylinder Spray Flow Characteristics in Direct-injection Gasoline Engine (직접 분사식 가솔린 엔진의 실린더 내 분무 유동 특성에 관한 연구)

  • 김진수;전문수;윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.51-59
    • /
    • 2000
  • In-cylinder spray flow motion plays an important in the adjustment of mixture preparation with a fundamental spray characteristics and in-cylinder flow field well in direct-injection gasoline engine. In this study, the fundamental spray characteristics such as mean drop size, velocity distribution, spray angle were measured and in-cylinder spray flow motion was visualized in order to optimize intake port, piston top land and combustion chamber shapes in the development stage of mass-produced G야 engine. For these experiments, the PDPA measurements and Mie scattering technique were used for detailed spray characteristics and in-cylinder spray motions were obtained by use of ICCD camera through the single-cylinder optical engine. From the experimental results, the test injector shows a good low-end linearity between the dynamic flow and fuel injection pulse width and the fuel spray of 20mm or less in SMD with good spray symmetry. In addition, the in-cylinder tumble flow has more effect on the homogeneous mixture formation than that of in-cylinder swirl flow at early injection mode and the in-cylinder swirl flow plays a better role of stratified mixture preparation than tumble flow at late injection mode.

  • PDF

A Study on the Performance Valuation of Small Size Water Storage Electric Boiler (소형 수축열식 전기 보일러의 성능 평가에 대한 연구)

  • Mo, Jong-Gun;Shin, Jae-Ho;Bae, Chul-Whan;Suh, Jeong-Se;Chung, Han-Sik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1524-1529
    • /
    • 2003
  • We was made 150L an water storage electric boiler and obtained various performances of the storage, radiant and keeping by experimentation, The storage performance is that the heat were off about 50 minutes after heating start, Then the temperature of outlet was arrived the stead state at $91^{\circ}C$ and the storage performances was appeared 93.64%, In the radiant performance, the water temperature was decreased from $90^{\circ}C$ to $44.8^{\circ}C$ after 960 minutes, Then the calorific value changed from 675kcal/h to 72kcal/h and the temperature decreased about 50%, The keeping performance showed mean temperature, $67.06^{\circ}C$ according to progress 800 minutes and the maximum temperature drop were $0.2^{\circ}C$, By the results of the performance valuation, the water storage electric boiler was verified fitted quality on the test prescription of KERI(Korea Electrotechnology Research Institute).

  • PDF

A study on the stability of turbulent diffusion flame in double swirl flows (이중선회류중의 난류확산화염의 안정화에 관한 연구)

  • 조용대;최병륜
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1669-1678
    • /
    • 1990
  • The annular and coaxial swirl flows between which LPG is supplied was selected to study the swirling flames in double co-swirl flows. The objective of this study is to research into the effects of double co-swirl flow conditions on the stability limit, the reverse flow boundary, and the time mean temperature distributions of the swirling flames. The increase of swirl intensity of axial flow makes the stability limit decrease, but the annular swirl flow (SM>0.5) makes stability and swirl intensity of axial flow increase, And the existence of axial swirl flow makes flame intensive and small in size, and this may be applicable to the design of high power compact combustor.

Evaluation of Residual Strength in Aircraft Composite Under Impact Damage (충격손상을 받은 항공기용 복합재료의 잔류강도 평가)

  • Choi, Jung-Hun;Kang, Min-Sung;Shin, In-Hwan;Koo, Jae-Mean;Seok, Chang-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.94-101
    • /
    • 2010
  • Composite materials have a higher specific strength and modulus than traditional metallic materials. Additionally, these materials offer new design flexibilities, corrosion and wear resistance, low thermal conductivity and increased fatigue life. These, however, are susceptible to impact damage due to their lack of through-thickness reinforcement and it causes large drops in the load-carrying capacity of a structure. Therefore, the impact damage behavior and subsequently load-carrying capacity of impacted composite materials deserve careful investigation. In this study, the residual strength and impact characteristics of plain-woven CFRP composites with impact damage are investigated under axial tensile test. Impact test was performed using drop weight impact tester. And residual strength behavior by impact was evaluated using the caprino model. Also we evaluated behavior of residual strength by change of mass and size of impactor. Examined change of residual strength by impact energy change through this research and consider impactor diameter in caprino model.

Spray Characteristics of a Liquid-Liquid Swirl Coaxial Injector Part II : Effect of Recess Configuration (액체-액체 스월 동축형 인젝터의 분무특성 Part II : 리세스 형상에 따른 영향)

  • Kim, Dong-Jun;Kim, Sung-Hyuk;Han, Poong-Gyoo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.9-17
    • /
    • 2006
  • The influences of recess length of a liquid/liquid swirl coaxial injector on spray characteristics were investigated. It was revealed that the internal impinging phenomenon played an important role in the spray characteristics, such as spray angle and breakup length. Also, as the recess length increased, the mean drop size increased due to the increase of effective film thickness and mixing efficiency increased, but in the case of very deep recess length, the mixing efficiency decreased.

A Study on the Characteristics of VOC Removal by Cordierite Filter Loaded with Catalyst (촉매를 담지한 코디어라이트 필터의 VOC 제거 특성에 관한 연구)

  • Chung, Kyung-Won;Kim, Yong-Nam;Park, Jeong-Hyun;Choi, Beom-Jin;Cho, Eul-Hoon;Lee, Hee-Soo
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.263-269
    • /
    • 2002
  • After porous filters were manufactured using cordierite powder whose mean particle size was 200 ${\mu}m$, they were loaded with catalysts such as Pt, Pd, Cu, Co, La, $V_2O_5$ by vacuum impregnation method. And we investigated the activity of catalysts used for catalytic oxidation of VOC by passing toluene through catalyst-loaded filters. The porous filters had the apparent porosity of 62%, the compressive strength of about 10 MPa and the pressure drop of 15 mmHg at the face velocity of 5 cm/sec. The loading of catalyst decreased the porosity of the filters and increased the pressure drop and the compressive strength of them. Among the catalysts, Pt had the highest activity for catalytic oxidation and could remove more than 90% of toluene at 250 $^{\circ}C$. Below 250 $^{\circ}C$, the content of Pt catalyst had an influence on the conversion of toluene but didn't show any influence above 250 $^{\circ}C$.

Development and Characterization of High Temperature Filter (내열성여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.103-112
    • /
    • 1998
  • A high temperature fabric filter was developed and characterized in order to solve the various problems encountered in the operation of industrial fabric filters. Four kinds of dusts generated in the typical domestic industry were used for its characterization, coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, fly ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physical and chemical properties of the high temperature fabric filter were analyzed in terms of mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, pore size distribution, and the changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres. Pressure drop, dust penetration, and figure of merit for the fabric filter were also investigated in a bench-scale filter testing unit. The fabric filter developed in this study had good physical and chemical filter properties and showed a very applicability to typical industrial dusts treatments.

  • PDF

Spray droplet size measurement using image processing technique (영상처리기법을 이용한 분무액적 크기의 측정)

  • 김인구;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1121-1129
    • /
    • 1988
  • An economic and efficient system for measuring drop sizes was developed. Pattern recognition technique was used with conventional oil-bath sampling and photographic method. The system was designed to measure and count relatively large number of drops in a very short time, and also to filter out abnormal images such as drops in contact or overlap as well as odd-shaped foreign materials. In this measuring system, most important error originates from the process of converting the original image to the binary image. If the photograph contains a large number of spray drops, the relative size of the pixel to the drops is not infinitesimally small; thus the proper choice of threshold level to convert the original image to the binary image becomes very important. In present case, most of the images lay in one of the two separate bands of brightness level and the arithmetic mean of the most popular brightness levels from each band was chosen as the threshold level. Present image processing system reduces the subjective error by the observers in counting and measuring drops and turns out to be substantially effective. The processing time can be further reduced by improving the hardware system concerned with the digital image coding.

A Study on Performance Evaluation based on Packet Dropping in ATM Network . New Scheme Proposal

  • Park, Seung-Seob;Yuk, Dong-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.27 no.3
    • /
    • pp.283-288
    • /
    • 2003
  • Recently, the growth of applications and services over high-speed Internet increases, ATM networks as wide area back-bone has been a major solution. As the conventional TCP/IP suite is still the standard protocol used to support upper application on current. Internet, the issues regarding whether TCP/IP will operate efficiently on top of an ATM infrastructure and how to control its QoS still remain for studies. TCP uses a window-based protocol for flow control in the transport layer. When TCP uses the UBR service in ATM layer, the control method is only buffer management. If a cell is discarded in ATM layer, one whole packet of TCP will be lost; this fact occur the most TCP performance degradation. Several dropping strategies, such as Tail Drop, EPD, PPD, SPD, FBA, have been proposed to improve the TCP performance over ATM. In this paper, to improve the TCP performance, we propose a packet dropping scheme that is based on comparison with EPD, SPD and FBA. Our proposed scheme is applied to schemes discussed in the previous technology. Our proposed scheme does not need to know each connection's mean packet size. When the buffer exceeds the given threshold, it is based on comparison between the number of dropped packet and the approved packet. Our results are reported and discussed for comparing these discarding schemes under similar conditions. Although the number of virtual channel (VC) is increased, the simulation results showed that the proposed scheme can allocate more fairly each VC than other scheme.

Spray Charateristics of Water/Oil Emulsified Fuel in Pressure-Swirl Nozzle (압력선회노즐에서 물-기름 유화연료의 분무특성)

  • Rhim, J.H.;No, S.Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.5-12
    • /
    • 2000
  • The beneficial aspects of applying emulsion fuels to combustion systems may be due to the changes of fuel properties which lead to the enhanced atomization characteristics. The spray characteristics of water/oil emulsified fuel injected from the pressure-swirl(simplex) atomizer using for oil burner were investigated. Four different water contents from 10 to 40 % by volume at 10% increment were prepared by mixing with the different contents of surfactants. Total amount of surfactant used was varied from 1 to 3 % by volume. This study demonstrates the influence of water and surfactant contents of emulsified fuel, injection pressure on the spray characteristics, i.e. Sauter mean diameter(SMD) and spray angle. The drop size distribution of the emulsified fuel spray was measured with a Malvem particle sizer. In order to measure the spray angle, the digital image processing was employed by capturing multiple images of the spray with 3-CCD digital video camera. It was evident that the addition of water and surfactant changes fuel properties which are the key parameters influencing the atomization of the spray. The increase in surfactant content results in the decrease of SMD and the increase in spray angle. The droplets decease with increase in injection pressure, but the influence of injection pressure in this experimental condition was less important than expected. The more viscous fuel with the increase of water content exhibits the larger droplets in the centerline of the spray, and the less viscous fuel in the outer edges of the spray. The increase in axial position from the nozzle causes the spray angle to decrease. The spray angle decreases with increase in water content. This is due to increase in viscosity with increase in water content.

  • PDF