• Title/Summary/Keyword: Mean diurnal variation

Search Result 97, Processing Time 0.049 seconds

Spaciotemporal Variation of PM10 and PM2.5 Concentration for 2015 to 2018 in Busan (부산지역 최근 4년간(2015~2018년) PM10과 PM2.5농도의 시·공간적 변화 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.29 no.7
    • /
    • pp.749-760
    • /
    • 2020
  • This study investigates the characteristics of diurnal, seasonal, and weekly roadside and residential concentrations of PM10 and PM2.5 in Busan, as well as relationship with meteorological phenomenon. Annual mean PM10 and PM2.5 concentrations in Busan were 44.2 ㎍/㎥ and 25.3 ㎍/㎥, respectively. The PM2.5/PM10 concentration ratio was 0.58. Diurnal variations of PM10 and PM2.5 concentrations in Busan were categorized into three types, depending on the number of peaks and times at which the peaks occurred. Roadside PM10 concentration was highest on Saturday and lowest on Friday. Residential PM10 concentration was highest on Monday and lowest on Friday. Residential PM2.5 concentration was highest on Monday and Tuesday and lowest on Friday. PM10 and PM2.5 concentrations were highest on Asian dust and haze, respectively. The results indicate that understanding the spaciotemporal variation of fine particles could provide insights into establishing a strategy to control urban air quality.

Feasibility of the Lapse Rate Prediction at an Hourly Time Interval (기온감률의 일중 경시변화 예측 가능성)

  • Kim, Soo-ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • Temperature lapse rate within the planetary boundary layer shows a diurnal cycle with a substantial variation. The widely-used lapse rate value for the standard atmosphere may result in unaffordable errors if used in interpolating hourly temperature in complex terrain. We propose a simple method for estimating hourly lapse rate and evaluate whether this scheme is better than the conventional method using the standard lapse rate. A standard curve for lapse rate based on the diurnal course of temperature was drawn using upper air temperature for 1000hPa and 925hPa standard pressure levels. It was modulated by the hourly sky condition (amount of clouds). In order to test the reliability of this method, hourly lapse rates for the 500-600m layer over Daegwallyeong site were estimated by this method and compared with the measured values by an ultrasonic temperature profiler. Results showed the mean error $-0.0001^{\circ}C/m$ and the root mean square error $0.0024^{\circ}C/m$ for this vertical profile experiment. An additional experiment was carried out to test if this method is applicable for the mountain slope lapse rate. Hourly lapse rates for the 313-401m slope range in a complex watershed ('Hadong Watermark 2') were estimated by this method and compared with the observations. We found this method useful in describing diurnal cycle and variation of the mountain slope lapse rate over a complex terrain despite larger error compared with the vertical profile experiment.

A Study on the Characteristics of Rural and Urban Surface Ozone Conentrations (청정지역과 도시지역의 오존농도 특성 연구)

  • 서명석;박경윤;이호근;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.253-262
    • /
    • 1995
  • A study has been performed on the characteristics of rural and urban surface ozone concentration for the period of March 1992 to February 1993. The monitoring station of rural ozone is located at Kosan, Cheju and other urban monitoring stations are located at Seoul, Pusan and Kwangju. Rural's and urban's ozone data exhibit a distinct features in many ways. First, annual mean of rural ozone concentration os very high(42 ppbv) but urban's are very low(10 .sim.15 ppbv). Second, rural ozone data shows a seasonal variation with it's maximum in spring, and minimum in summer, but urban's show a seasonal variation with it's maximum in spring, and minimum in winter. Third, diurnal variation of rural data is very small but that of urban's are very large. Fourth, urban's data are extremely low(< 3 ppbv) and have no seasonal variations.

  • PDF

Seasonal and Diurnal Variations of Surface Ozone at Ieodo in the East China Sea (이어도 해양과학기지의 오존농도의 계절변화와 일변화 특징)

  • Shin, Beom-Cheol;Lee, Mee-Hye;Lee, Jae-Hak;Shim, Jae-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.631-639
    • /
    • 2007
  • We examined diurnal and seasonal variations of ozone ($O_3$) concentrations and its relation to meteorological parameters observed at the Ieodo Ocean Research Station ($32.07^{\circ}N$, $125.10^{\circ}E$, 36 m above sea level) during June 2003 and May 2005. Over the 2-year period, the mean ozone concentration was $49.5{\pm}15.5\;ppbv$. Ozone concentrations show great variability with a monthly mean up to 68.2 ppbv in May 2005 and seasonal variations with being highest in spring and fall, and lowest in summer. However, the amplitude of diurnal variation was less than ${\sim}4\;ppbv$ with a maximum at $3{\sim}4\;p.m.$ and minimum at $7{\sim}8\;a.m.$ HYSPLIT backward air trajectory indicated that the air masses with higher ozone came from the north or northwest and those with lower ozone arrived mainly via southerly or southeasterly. Ozone distributions at Ieodo Ocean Research Station were observed to be significantly impacted by long-range transport and regional scale air circulation.

A point-scale gap filling of the flux-tower data using the artificial neural network (인공신경망 기법을 이용한 청미천 유역 Flux tower 결측치 보정)

  • Jeon, Hyunho;Baik, Jongjin;Lee, Seulchan;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.929-938
    • /
    • 2020
  • In this study, we estimated missing evapotranspiration (ET) data at a eddy-covariance flux tower in the Cheongmicheon farmland site using the Artificial Neural Network (ANN). The ANN showed excellent performance in numerical analysis and is expanding in various fields. To evaluate the performance the ANN-based gap-filling, ET was calculated using the existing gap-filling methods of Mean Diagnostic Variation (MDV) and Food and Aggregation Organization Penman-Monteith (FAO-PM). Then ET was evaluated by time series method and statistical analysis (coefficient of determination, index of agreement (IOA), root mean squared error (RMSE) and mean absolute error (MAE). For the validation of each gap-filling model, we used 30 minutes of data in 2015. Of the 121 missing values, the ANN method showed the best performance by supplementing 70, 53 and 84 missing values, respectively, in the order of MDV, FAO-PM, and ANN methods. Analysis of the coefficient of determination (MDV, FAO-PM, and ANN methods followed by 0.673, 0.784, and 0.841, respectively.) and the IOA (The MDV, FAO-PM, and ANN methods followed by 0.899, 0.890, and 0.951 respectively.) indicated that, all three methods were highly correlated and considered to be fully utilized, and among them, ANN models showed the highest performance and suitability. Based on this study, it could be used more appropriately in the study of gap-filling method of flux tower data using machine learning method.

A Study of the Intraocular Pressure of Korean Youth (한국인 청년의 안압 측정)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.91-97
    • /
    • 2006
  • The intraocular pressure for Korean youth were measured by using tonometer (AT555-Reichert). The relative frequency distributions of intraocular pressures have been studied for samples of 1,027 persons(475 males, 552 females). The most commonly recorded IOP for both men and women was around 14.5mmHg and 17.5mmHg, respectively. They were in the range of 7 to 23mmHg(males) and 7 to 22mmHg(females). The median pressure(cumulative frequency=0.5%) is 13.0~16.5mmHg for males and 16.5~18.5mmHg for females, so the values for females are slightly higher than males. The mean pressure is 15.2mmHg for males and 15.8mmHg for females, respectively. The 98% of population was in the range of the normal IOP. There are long-term diurnal variation in mean intraocular pressure and the IOP was decreased as a function of time from morning to night. The measured IOP was affected by several factors: exercise made to decrease the IOP and tight collars, dark places and posture of decubitus position got to elevate the IOP.

  • PDF

A Study on the Diffusion of Atmospheric Pollutants over Taegu (대구상공에서의 대기 오염 물질 확산에 관한 연구)

  • Yun, Il-Hui;Min, Gyeong-Deok;Park, Dong-Jae
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.241-252
    • /
    • 1994
  • Meteorological parameters In the atmospheric boundary layer and the vertical and horizontal dispersion parameters were determined by analyzing the data obtained by the special upper-air observations of one clear day for each season from October 1991 to August 1992. The concentration of the aklospheric pollutants over Taegu was analyzed by using the application of the Gaussian diffusion model. In the diurnal variation of diffusion of atmospheric pollutants, vertical diffusion due to turbulence is active in daytime while horizontal diffusion due to wind is active in nighttime. The mean concentration of pollutants in the side of downwind is higher during the daytime than the nighttime. Thus, the height of the mixed-layer at the nighttime considered as the most important parameter of the mean concentration of pollutants. In the seasonal variation of diffusion of atmospheric pollutants, vertical diffusion due to strong solar radiation is active in summer case day, and horizontal diffusion due to strong wind is active in winter case day. In winter case day, the mean concentration of pollutants in the side of downwind is maximum in the daytime. However, in summer case day, that is maximum in the nighttime.

  • PDF

Vertical Profiles of CO2 Concentrations and CO2 Storage in Temperate Forest in Korea (한국 활엽수림의 이산화탄소 농도의 연직구조와 저류항)

  • Thakuri, Bindu Malla;Kang, Minseok;Chun, Jung Hwa;Kim, Joon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2013.11a
    • /
    • pp.23-24
    • /
    • 2013
  • Micrometeorological fluxes measured over a tall forest in a complex terrain are difficult to interpret. $CO_2$ storage often makes significant contributions to net ecosystem exchange of $CO_2$ (NEE) in early morning and during nighttime due to calm and stable conditions. We measured the above-canopy $CO_2$ flux along with its concentration profiles at eight levels within and above the canopy to evaluate $CO_2$ storage term. Our question is whether or not the $CO_2$ storage term can be estimated accurately from a single level measurement of $CO_2$ concentration in a complex terrain. Our objectives are (1) to document vertical profiles of $CO_2$ concentration and (2) to compare the diurnal and seasonal variations of $CO_2$ storages estimated from single and multi-level $CO_2$ concentration data. Seasonally averaged Diurnal variations of $CO_2$ concentration ranged from 398 to 455 ppm near the forest floor at 0.1 m whereas they ranged from 364 to 395 ppm at 40 m in the atmosphere. The diurnal variation of vertical profiles of $CO_2$ concentration shows very interesting features with season. At all eight levels, diurnal variation of $CO_2$ concentration showed little change in winter. In spring, the diurnal variations of $CO_2$ concentration at 8 levels showed three distinct groups of layers with height: the first layer: 0.1m (near surface), second layer: 1.0 m and 4.0m (below canopy) and the third layer: 7.4m to 40.7 m (near canopy and above). In summer, these three groups of layers were further separated with larger variations whereas such distinction became smaller in fall. The diurnal variation of $CO_2$ concentration in the first three layers near surface always showed higher concentration with larger variability. Typically, $CO_2$ concentration showed peaks in early morning and in the evening. After the evening peak, $CO_2$ concentration gradually increased except for those near the surface (i.e., 0.1, 1.0 and 4.0 m) where the concentrations actually decreased. We suspect that this could be attributed to the drainage flow of $CO_2$ along the hill slope from the headwater to downstream, which is not taken into account for net ecosystem $CO_2$ exchange. In comparison to the results of other studies, the distinct and different vertical structures of $CO_2$ concentrations observed at our site may be due to complex terrain and weak turbulent mixing under calm conditions at the site. The annual mean of diurnal variation of $CO_2$ storage flux from single level ranged from -0.6 to $0.9{\mu}mol\;m^{-2}s^{-1}$ and from multi-level from -1.2 to $1.0{\mu}\;{\mu}mol\;m^{-2}s^{-1}$. When compared against the results from the multi-level concentrations, the storage flux estimated from a single-level concentration was generally adequate except for specific hours near sunrise and sunset. Further details and their implication will be discussed in the presentation.

  • PDF

Studies on the Behaviour of Ozone Concentration and the Influencing Factors (오존농도의 動態 및 影響因子에 關한 硏究)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

LOCAL TIMES OF GALACTIC COSMIC RAY INTENSITY MAXIMUM AND MINIMUM IN THE DIURNAL VARIATION (우주선 세기 일변화 최대 및 최소 지방시)

  • Oh Su-Yeon;Yi Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2006
  • The Diurnal variation of galactic cosmic ray (GCR) flux intensity observed by the ground Neutron Monitor (NM) shows a sinusoidal pattern with the amplitude of $1{\sim}2%$ of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum aad minimum. To test the influences of the solar activity and the location (cut-off rigidity) on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum) and 2000 (solar maximum) at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV) and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV) NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about $2{\sim}3$ hours in the solar activity maximum year 2000 than in the solar activity minimum you 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by $2{\sim}3$ hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.