• Title/Summary/Keyword: Mean air-age

Search Result 188, Processing Time 0.028 seconds

The Effect of Air Pollution on Allergic Diseases Considering Meteorological Factors in Metropolitan Cities in Korea (서울 및 6대 광역시의 기상요인을 고려한 대기오염이 주요 알레르기질환에 미치는 영향)

  • Kim, Hyo-Mi;Heo, Jin-A;Park, Yoon-Hyung;Lee, Jong-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.184-194
    • /
    • 2012
  • Objectives: We investigated the effects of air pollution on allergic diseases (allergic rhinitis, asthma, atopic dermatitis) in metropolitan cities in Korea, adjusting for meteorological factors. Methods: Data on daily hospital visits and hospital admissions for 2003-2010 was obtained from the National Health Insurance Cooperation. Meteorological data was obtained from the Korea Meteorological Administration. We then calculated daily mean temperature, daily mean humidity, daily mean air pressure at sea level, and diurnal temperature range. We used data on air pollution provided by the National Institute of Environmental Research. Maximum daily eight-hour average ozone concentrations and the daily mean $PM_{10}$ were used. We estimated excess risk and 95% confidence interval for the increasing interquatile range (IQR) of each air pollutant using Generalized Additive Models (GAM) that appropriate for time series analysis. Results: In this study, we observed an association between ozone and hospital visits for allergic rhinitis, asthma, and atopic dermatitis in all metropolitan cities, adjusting for temperature, humidity, air pressure at sea level, diurnal temperature range, and day of the week. Ozone was associated with hospital visits for allergic rhinitis, asthma, and atopic dermatitis across all metropolitan cities. However $PM_{10}$ was associated with allergic-related diseases in only select cities. Also, ozone and $PM_{10}$ were associated with hospital admission for asthma in all cities except Gwangju. Hospitalization for the other diseases failed to show consistent association with air pollutants. Conclusion: In the findings of this study, there was a significant association between air pollutants and allergic-related diseases. More detailed research subdivided age group or conducting meta-analyses combining data of all cities is required.

A Specific Character on the Urinary Hippuric Acid Excretions of Workers Exposed to Toluene in Specific Character of Manufacturing Industry (작업장 특성에 따른 톨루엔 노출 근로자의 마뇨산 배출 특성)

  • Park Heung-Jai;Kim Hyung-Joon;Jeong Seong-Wook;Lee Byung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.201-207
    • /
    • 2005
  • This study was carried out to investigate the correlation between toluene in air and hippuric acid in human urine, which is based in the results of the health check-in and measure of working environment, was investigated for five years. Toluene in air and hippuric acid in urine were checked 116 workers who exposed to toluene in five type of industry. The Mean concentration of toluene in air by type of industry and every year and sex distinction, had positive correlation.(p<0.01) The Mean concentration of hippuric acid in urine by type of industry, every year, sex distinction, disparity of age and term of duty had positive correlation.(p<0.01).

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

The study on the effect of the solar radiation on thermal comfort and ventilation performance in room space (태양일사가 실내공간의 열적 쾌적성과 환기성능에 미치는 영향에 관한 연구)

  • Yeon, Seong Hyeon;Lee, Hyo Joon;Rhee, Gwang Hoon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • Modern people spend much time at indoor space. So, People want to make better indoor air condition. But the facade of building is made of glass to be seen urbanely, the effect of solar radiation makes indoor environment worse. This study designs an open space affected by solar radiation with 4-way cassette air-conditioner. Using numerical simulation, this paper investigates thermal comfort and ventilation performance with discharge angles $30^{\circ}$ and $45^{\circ}$. To study thermal comfort, this paper studies distribution of velocity, temperature and effective draft temperature. Also, this paper introduces concept of air age to study ventilation performance. The flow influenced by solar radiation determines thermal comfort and ventilation performance in room space. This study shows that discharge angle of 45 degree has better thermal comfort and ventilation performance than that of 30 degree.

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.11
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

Evaluation of Ventilation Efficiency for Various Gravity Ventilators (자연환기 벤틸레이터 형태에 따른 환기효율 평가)

  • 하현철;김태형
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.543-551
    • /
    • 2002
  • Gravity ventilators allow the escape of the warm air and air contaminants due to both (either) buoyancy and (or) convection. As a natural ventilation strategy, various gravity ventilators can be installed on the roof. Ventilation efficiency could be affected by various parameters, such as, area of openings, wind velocity and incidence angle, temperature difference between inside and outside, and shape of ventilator. Especially, the shape of roof gravity ventilator might be one of influencing factors for the effective ventilation. The window type gravity ventilators are frequently installed instead of general (standard) gravity ventilator. However, the ventilation efficiencies of them were not proved yet. To compare the ventilation efficiency, general type ventilator and two window type ventilators were numerically tested. Mean age of air, temperature and CO concentration were predicted by using commercial CFD code, AIRPAK (Ver. 2.0) with various conditions. The predicted result showed that general type ventilator is more effective for natural ventilation than window type ventilators.

A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses (소형 공동주택의 하이브리드 환기시스템 성능실험 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Lee, Jong-Sung;Kim, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

The Relationship Between Hippuric Acid in Blood Plasma and Toluene Concentration in the Air of Workplace (톨루엔 폭로근로자의 혈장중 마뇨산과 공기중 톨루엔과의 상관관계)

  • Hwang, Cheon-Hyun;Lee, Won-Jin;Chang, Soung-Hoon;Kim, Hyoung-Ah
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Objectives : This study was undertaken to evaluate correlation between the levels of hippuric acid in blood plasma (HAP) and those of toluene concentration in the workplace air. Methods : Study subjects were composed of two groups; 21 workers who were occupationally exposed to toluene and 25 rural-area residents who were not exposed to any known occupational toluene source, as an exposed group and a reference group, respectively. Mean age and work duration of the exposed was 42 years and five years, respectively. Mean age of the reference was 42 years. To determine toluene concentrations in the workplace air, air sampling has been conducted for more than six hours using a personal sampler, and analyzed by a gas chromatography-flame ionization detector. Concentrations of hippuric acid in biological samples were determined by a high performance liquid chromatography-ultraviolet detector. Results : Geometric mean(geometric standard deviation) of HAP and hippuric acid in urine(HAU) for the exposed was 1.39(2.21) mg/L and 2.77(1.46) g/L, respectively, which were significantly different from those of the reference [HAP, 9.45(2.94); HAU, 0.37(0.45)]. Teluene concentration in the workplace air was 86.92(range: $45.18\sim151.23$)ppm. The level of HAP or HAU was significantly correlated (r=0.70 and r=0.63, respectively) with that of toluene in the workplace air. The estimated regression equation was logHAP(mg/L)=-3.60+1.93 log(toluene, ppm) or logHAU(g/L)=-0.85+0.67 log(toluene, ppm). The magnitude of correlation was further enhanced when analyzing relationship between toluene concentrations lower than 100 ppm and its corresponding HAP levels. Conclusion : Overall, plasma hippuric acid levels were well correlated with toluene concentrations in the workplace air, and a statistically significant correlation was observed for the samples with toluene concentration lower than 100 ppm.

  • PDF

A Study on the Blood Manganese Levels in Welding Workers

  • Lee, Mi-Hwa
    • Biomedical Science Letters
    • /
    • v.9 no.4
    • /
    • pp.223-229
    • /
    • 2003
  • The welding workers are frequently exposed to heavy metals such as manganese. Manganese is well evaporated into the air while welding. This study had been carried out to investigate the relationship of the blood manganese level to age, work duration, and smoking status among 128 welding workers in Gyeongnam and Jeonnam province from May to November, 2003. They showed high manganese level in the first health examination. Subjects were also classified for the investigation according to their smoking status as smokers and nonsmokers, work duration ($\leq$9, 10~9, 20$\leq$years), and ages ($\leq$29, 30~39, 40~49, 50$\leq$years). Blood manganese Jevels were analyzed by atomic absorption spectrophotometer (AAS). Mean blood manganese level was 1.62$\pm$0.56 $\mu\textrm{g}$/dl. In the comparison of blood manganese levels by age and smoking status, mean blood manganese levels of smokers in age of 20's, 30's, and 50's were 2.09$\pm$0.44 $\mu\textrm{g}$/dl, 1.94$\pm$0.33 $\mu\textrm{g}$/dl, and 2.l5$\pm$0.33 $\mu\textrm{g}$/dl, respectively. Blood manganese levels of smokers were significantly higher than those of non-smokers, showing no significant difference in the 40's. In the comparison of blood manganese levels by work duration, the blood manganese levels of smokers were the highest in the case of 10 to 19 years work duration. This study showed that the blood manganese levels were related to the smoking status, work duration, and age. Mean manganese levels of smokers showed higher than those of nonsmokers. It also showed that the length of work duration was related to the elevation of blood manganese levels. Among the welding workers, blood manganese levels of smokers were the highest over their age of 50's. In conclusion, smoking was the most significant risk factor to increase blood manganese levels. The further study will need analysis of the other factors related to manganese level elevation.

  • PDF