• Title/Summary/Keyword: Mean air flow rate

Search Result 167, Processing Time 0.027 seconds

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

The Clinical Analysis of Sulcus Vocalis (성대구증에 관한 임상적 고찰)

  • 김광문;서장수;오혜경;최홍식;김기령
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.11.2-12
    • /
    • 1982
  • The major advancement in phonosurgery due to recent development of laryngomicrosurgery enabled more accurate diagnosis and treatment of patient with voice disorders. Among large proportion of voice disordered patients, prominent linear furrow running parallel along the free edge of vocal cord extending from the vocal process to anterior commissure can be seen as well as incomplete closure during phonation. These cases were illustrated and coined as sulcus vocalis by Salvi in 1901, since then other similar paper was reported in Europe and Japan, but has not been reported in Korea. The exact etiology and therapeutic methods of sulcus vocalis has not been elaborated. At Department of Otolaryngology of Yonsei University College of Medicine a series of voice analysis were performed among those 35 patients with sulcus vocalis visited to Vocal Dynamics Laboratory from May, 1981 to March, 1982. Following is the result of clinical statistical investgation and therapeutic modality. 1) The incidance of sulcus vocalis among 290 patients with voice disorder visited to Vocal Dynamics Laboratory was approximately 12%(35 cases). 2) Onset of this voice disorder was most frequent among patient under 10 year-old groups; 19 cases (54%) followed by second decade, third decade groups in decreasing frequency respectably. 3) The etiology of sulcus vocalis was mostly unknown. The sequelae after measle (4 cases) and severe upper respiratory infection (3 cases) and congenital deformity (2 cases) were the possible causes of sulcus vocalis. 4) These patients were involved bilaterally in 25 cases (71%), left side only in 8 cases (23%) and right side only in 2 cases (6%). 5) Almost all patients complained hoarseness and 7 patients were suffering from chronic laryngitis. 6) In aerodynamic analysis, Maximal Phonation Time was decreased in 20 cases (57%), Phonation Quotient was increased in 22 cases (63%) and Mean Air Flow Rate was increased in 23 cases (66%). 7) Among them, 33 cases were analyzed with stroboscopy. The findings were as follows; incomplete glottic closure during phonation in 31 cases (93%), regular vocal cord movement in whole cases, asymmetric cord movement in 4 cases (12%), decreased amplitude in 5 cases (21%) and small mucosal wave in 24 cases (73%). 8) Intracordal Teflon injection in 5 cases and Sulcusectomy in 1 cases were performed as therapeutic management, however, the therapeutic results were not effective except one case with Teflon injection.

  • PDF

Wearable wireless respiratory monitoring system (의복착용형 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

A Study on Combustion Characteristics in terms of the Type of Fuel Supply Device (Feeder) of a Wood Pellet Boiler (목재펠릿보일러의 연료공급 장치의 형태에 따른 연소특성에 관한 연구)

  • Choi, Yun Sung;Euh, Seung Hee;Oh, Kwang Cheol;Kim, Dae Hyun;Oh, Jae Heun
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • This study reports the combustion characteristics, such as burner temperature and the concentration of exhausted gas ($O_2$, $CO_x$, $NO_x$) due to the different types and pitches of the fuel supply feeder of the wood pellet boiler. The 1st grade wood pellets composed of mainly larch have been used for the experiment. In case of using the spring feeder, mean temperature of burner was approximately $821.76^{\circ}C$, and the mean concentration of oxygen, carbon monoxide, carbon dioxide and nitrogen oxide were approximately 8.88%, 93.35ppm, 12.15% and 139.83 ppm, respectively. The test result with the spring feeder was shown to approach the condition of complete combustion compared to that of a screw feeder and were in good agreement with authentication judgement standard. Furthermore, the combustion efficiency was improved according to the growth of screw pitch. The control of air flow rate from the blower and ventilator is needed to achieve the complete combustion.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.

Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed (기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교)

  • Lee, Youngjae;Kim, Jongmin;Kim, Donghee;Lee, Yongwoon
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.80-89
    • /
    • 2017
  • The bubbling fluidized bed (BFB) reactor with a diameter of 0.1 m and a height of 1.2 m was used for experimental study of co-firing and emission characteristics fueled by sewage sludge (SS) and wood pellet (WP). The facility consists of a fluidized bed reactor, feeding system, cyclone, condenser and gas analyzer, The mean particle diameter and minimum fluidization velocity are $460{\mu}m$ and $0.21ms^{-1}$ respectively. SS produced from Korea and WP from Canada were examined. The various mixing ratios of WP were 20, 50, and 80% based on HHV. The equivalence ratio of 1.65, reactor temperature of $800^{\circ}C$, air flow rate of $100Lmin^{-1}$, and fluidization number of 4 were fixed in the BFB experiment. In TGA, the range of combustion temperature of SS was wider than that of WP. It represents that the combustibility of WP is higher than that of SS. The BFB reactor temperature was maintained between 800 and $900^{\circ}C$. CO emission of SS was high because of lower combustibility. $NO_X$ and $SO_X$ formation of SS were higher than that of WP since high nitrogen and sulfur contents of SS. CO, $NO_X$, and $SO_X$ formation were suppressed as the mixing ratio of WP was increased. The slagging and fouling tendencies show high in all test conditions.

Clinical Validation of Nebulized Budesonide and Effect of Nebulized Budesonide on the Hypothalamic-Pituitary-Adrenal Axis in Adult Patients Admitted with Acute Asthmatic Attack (급성 발작으로 내원한 성인 천식 환자에서 Nebulized Budesonide의 임상적인 효과와 시상하부-뇌하수체-부신 축에 대한 작용)

  • Seo, Ki-Hyun;Moon, Seung-Hyug;Kim, Yong-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.5
    • /
    • pp.529-538
    • /
    • 2002
  • Background : Many clinicians are reluctant to prescribe systemic corticosteroids to manage an asthmatic attack because of many complications such as osteoporosis, cushing's syndrome, diabetes, hypertension and bleeding tendency. The use of nebulized budesonide may be of value in some infants, old men, and in particular adult asthmatic patients who complain of severe dyspnea. A clinical validation and steroid-sparing effect of nebulized budesonide in asthmatic adults and COPD were evaluated, and the short-term effects of budesonide use on the HPA axis were assessed. Materials and Methods : Study A was prospectively done with 41 patients diagnosed with pure asthma and 30 patients diagnosed with COPD (including asthmatic component) in Soonchunhyang Hospital, Chunan from June. 2000 to Sep. 2001. They were treated with nebulized budesonide including systemic steroids (Group 1), a budesonide tubuhaler including a systemic steroid (Group 2), or only the systemic steroid(Group 3). The peak flow rate, arterial blood gas in room air, pulmonary function test, symptom scoring, steroid amount and hospital stay were analyzed. Study B was conducted with 19 patients to evaluate the short-term effects on the HPA axis of treatment with nebulized budesonide 1mg twice daily and a budesonide turbuhaler 5 puffs twice daily. The adrenal function was assessed prior to budesonide inhalation and after 7 days of budesonide inhalation. Results : In the pure asthmatic patients, the mean value of the symptoms (dyspnea, wheezing, cough, night asthma) or the arterial BGAs, total amounts of steroid or hospital stay and the difference in the results of the pulmonary function tests or peak expiratory flow rate were similar in the three groups. In COPD with an asthmatic component, there were no significant differences among the three groups. Although nebulized budesonide suppressed HPA function,(p=0.006) the HPA responses from the nebulized budesonide and turbuhaler budesonide were similar (p=0.288) Conclusion : This result suggests that systemic steroid should only be made available for acute asthmatic patients irrespective of the inhaled budesonides. Nebulized budesonide at the therapeutic dose has similar effects on the HPA axis compared to that of turbuhaler budesonide.