• Title/Summary/Keyword: Mean Flow

Search Result 3,212, Processing Time 0.024 seconds

An Investigation on Turbulent Flow Characteristics According to the Operating Loads of Three-Dimensional Small-Size Axial Fan by Large Eddy Simulation (대규모 와 모사에 의한 3차원 소형축류홴의 운전부하에 따른 난류유동 특성치 고찰)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.50-56
    • /
    • 2016
  • This paper handled an investigation on the turbulent flow characteristics of three-dimensional small-size axial fan(SSAF) according to operating loads. Also, it was carried out by unsteady-state, incompressible and three-dimensional large eddy simulation(LES). The downstream flow type of SSAF is changed from axial flow to radial flow around the beginning of stall region at the aerodynamic performance curve. Axial mean velocity component largely grows around blade tip at the operating point of A to D, but transverse and vertical mean velocity components as well as Reynolds shear stresses highly develop around blade tip at the operating point of E to H. On the other hand, the peak value of turbulent kinetic energy developed around blade tip shows the highest at the operating point of E.

A Study on the Drag Reduction with Polymer Additives (고분자물질(高分子物質) 첨가(添加)에 따른 마찰저항감소(摩擦抵抗減少)에 관한 연구(硏究))

  • Kim, J.G.;Cha, K.O.;Choi, H.J.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.198-207
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity, and turbulent intensity whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with the inner diameter of 24mm and the length of 1,500mm. The polymer materials used are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results showed that the drag reduction of co-polymer is higher than that of polyacrylamide. Mean liquid velocities increased as polymer was added, and turbulent intensity decreased inversely near the pipe wall.

  • PDF

Large-eddy simulation and wind tunnel study of flow over an up-hill slope in a complex terrain

  • Tsang, C.F.;Kwok, Kenny C.S.;Hitchcock, Peter A.;Hui, Desmond K.K.
    • Wind and Structures
    • /
    • v.12 no.3
    • /
    • pp.219-237
    • /
    • 2009
  • This study examines the accuracy of large-eddy simulation (LES) to simulate the flow around a large irregular sloping complex terrain. Typically, real built up environments are surrounded by complex terrain geometries with many features. The complex terrain surrounding The Hong Kong University of Science and Technology campus was modelled and the flow over an uphill slope was simulated. The simulated results, including mean velocity profiles and turbulence intensities, were compared with the flow characteristics measured in a wind tunnel model test. Given the size of the domain and the corresponding constraints on the resolution of the simulation, the mean velocity components within the boundary layer flow, especially in the stream-wise direction were found to be reasonably well replicated by the LES. The turbulence intensity values were found to differ from the wind tunnel results in the building recirculation zones, mostly due to the constraints placed on spatial and temporal resolutions. Based on the validated mean velocity profile results, the flow-structure interactions around these buildings and the surrounding terrain were examined.

Distributions of the velocity and pressure of the pulsatile laminar flow in a pipe with the various frequencies (주파수의 변화에 따른 원형관로내 층류맥동유동의 속도와 압력의 분포)

  • Bae, S.C.;Mo, Y.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.561-571
    • /
    • 1997
  • In this paper, the fundamental equations are developed for the pulsatile laminar flow generated by changing the oscillatory flow with $0{\leq}f{\leq}48Hz$ into a steady one with $0{\leq}Re{\leq}2500$ in a rigid circular pipe. Analytical solutions for the wave propagation factor k, the axial distributions of cross-sectional mean velocity $u_m$ and pressure p are schematically derived and confirmed experimentally. The axial distributions of centerline velocity and pressure were measured by using Pitot-static tubes and strain gauge type pressure transducers, respectively. The cross-sectional mean velocity was calculated from the centerline velocity by applying the parabolic distribution of the laminar flow and it was confirmed by using the ultrasonic flowmeter. It was found that the axial distributions of cross-sectional mean velocity and pressure agree well with theoretical ones and depend only on the Reynolds number Re and angular velocity $\omega$.

  • PDF

An experimental study of a flow field generated by a rotating cylinder on a plane moving at free stream velocity (자유흐름 속도의 이동면과 맞닿은 회전실린더 주위 유동장의 실험적 해석)

  • Park, Un-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.700-712
    • /
    • 1997
  • The flowfield generated by a 2-D rotating cylinder on a plane moving at freestream velocity was experimentally investigated in a wind tunnel to simulate aerodynamic characteristics of rotating wheels of an automobile. In the flowfield around a rotating cylinder at 3*10$^{3}$ < Re$_{d}$<8*10$^{3}$, unique mean flow and turbulence characteristics were confirmed by hot-wire measurements as well as frequency analysis, which was supported by flow visualization. In the vicinity of a rotating cylinder, a unique turbulence structure on .root.over bar u'$^{2}$ profiles was formed in hump-like shape at 1 < y/d < 3. A peak frequency which characterized the effect of a rotating cylinder had the same value of the rotation rate of a cylinder. In case of cylinder rotation, the depths of mean velocity -defect and turbulent-shear regions were thickened by 20-40% at 0 < x/d < 10 compared with the case of cylinder stationary. Far downstream beyond x/d > 10, the flowfield generated by a rotating cylinder showed self-similarity in the profiles of mean velocity and turbulence quantities. The effect of a rotating cylinder was independent of its rotation rate and Reynolds number in the measurement range.

Effect of Modified Blalock-Taussig Operation on Pulmonary Arterial Growth (변형 Blalock-Taussig 수술법이 폐동맥성장에 미치는 영향)

  • Park, Seung-Il;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.256-264
    • /
    • 1989
  • Modified Blalock-Taussig operation remains the standard technique of systemic-to-pulmonary artery shunt in patients of congenital heart disease with decreased pulmonary blood flow. We reviewed the 41 patients who had been performed modified Blalock-Taussig operation from March 1985 to Feb. 1988, and angiographically measured pulmonary artery size before and after shunt, and calculated pulmonary artery index [PAI] and ratio of left and right pulmonary artery to descending aorta[[LPA+RPA]/dAo]. The mean duration of palliation after shunt operation was 624 days and mean age of the patient at shunt operation was 3.59 years. Mean PAI increased significantly from 131.15*67.11 mm2/M2 preoperatively to 232.70*84.46 mm2/M2 postoperatively. Mean ratio of right and left pulmonary artery to descending aorta also increased significantly from 1.48*0.40 preoperatively to 1.92*0.50 postoperatively. All patients manifested clinical improvement; there was mean decrease in hematocrit of 8.95%, mean increase in arterial oxygen saturation of 11.08%. Pulmonary arterial growth was not influenced by age at operation, initial pulmonary artery size, or graft size, but significantly influenced by antegrade flow. The patients who have some antegrade flow were in more increase of PAI. There were no linear correlation between change of PAI, change of [[LPA+RPA]/dAo], SaO2, and duration. But, according to Scatterplot between change of PAI and duration, some complex correlation was suggested and mean PAI was decreased after 2-year palliation. We concluded that modified Blalock-Taussig operation is excellent palliative surgery for pulmonary artery growth especially on the patient who have some antegrade flow, and the proper duration of palliation was about 2 years.

  • PDF

Developing Job Flow Time Prediction Models in the Dynamic Unbalanced Job Shop

  • Kim, Shin-Kon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.1
    • /
    • pp.67-95
    • /
    • 1998
  • This research addresses flow time prediction in the dynamic unbalanced job shop scheduling environment. The specific purpose of the research is to develop the job flow time prediction model in the dynamic unbalance djob shop. Such factors as job characteristics, job shop status, characteristics of the shop workload, shop dispatching rules, shop structure, etc, are considered in the prediction model. The regression prediction approach is analyzed within a dynamic, make-to-order job shop simulation model. Mean Absolute Lateness (MAL) and Mean Relative Error (MRE) are used to compare and evaluate alternative regression models devloped in this research.

  • PDF

Effect of SAENGMAEKSAN extract on blood pressure and, regional cerebral blood flow (생맥산(生脈散)이 혈압(血壓) 및 국소뇌혈류량(局所腦血流量)에 미치는 영향(影響))

  • Sin, Dae-Cheol;Kim, Yeong-Gyun;Han, Jong-Hyeon;Mun, Gu;Kim, Jae-Seop
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.167-176
    • /
    • 1997
  • The purpose of this study was to investigate the effect of SAENGMAEKSAN extract on blood pressure and regional cerebral blood flow in rats. 1. High concentration of SAENGMAEKSAN extract decresed mean blood pressure in rats. 2. By depend on the dosage of SAENGMAEKSAN extract incresed mean regional cerebral blood flow in rats.

  • PDF

Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler (Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察))

  • Lim, Jong-Pil;Bae, Na-Young;Han, Kyung-Soo;Ahn, Taek-Won
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

Pressure-Oscillation Damping Characteristics of an Orifice in a Fluid Feeding Line with Mean Flow (평균유동이 있는 유체 공급배관내 오리피스의 압력섭동 감쇠 특성)

  • Lee, Tae-Young;Kim, Chul-Jin;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.359-362
    • /
    • 2009
  • Damping characteristics of pressure oscillation induced by an orifice in fluid feeding line for are investigated numerically and experimentally. Assuming small pressure oscillation, acoustic damping effect of orifice is confirmed experimentally, and with the mean flow, damping characteristics of an orifice are investigated numerically. When an orifice is installed at the node of pressure oscillation corresponding to the anti-node of velocity oscillation, suppression of pressure oscillation is maximized and with the mean flow, the resonant frequency is decreased. And, it is found that the optimal position of an orifice for damping shouled be changed.

  • PDF