• Title/Summary/Keyword: Mean Flow

Search Result 3,203, Processing Time 0.034 seconds

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

Characteristics and Control of Microthrix Parvicella Bulking in Biological Nutrient Removal Plant (생물학적 영양소제거공정에서 Microthrix Parvicella에 의한 Bulking 특성 및 제어)

  • Lee, H.;Ahn, K.
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1101-1106
    • /
    • 2006
  • Many BNR (Biological Nutrient Removal) plants have experienced a bulking problem, mainly due to the growth of filamentous organisms, particularly during the winter months. This study investigated the problem of bulking due to the growth of M. parvicella both at a full-scale municipal wastewater treatment plant and a pilot scale plant located in the C city. The full-scale facility was operated at a flow rate of $51,000m^3/d$, an F/M (Food-to-Microorganism) ratio of 0.12 kgBOD/kgMLVSS/d and an SRT (Solids Retention Time) higher than 25 days, respectively. This plant experienced bulking and foaming problems at low temperatures below $15^{\circ}C$ since it was retrofitted with the BNR system in 2003. The pilot plant employed had an identical process configuration as the full scale one and used the same wastewater source. It was operated at a flow rate of $3.8m^3/d$, temperatures between 10 to $25^{\circ}C$ and SRTs between 10 and 25 days. At full scale, the M. parvicella growth and SVI (Sludge Volume Index) patterns were studied in conjunction with temperature variations. At pilot scale, DO and SRT variations were also explored, in addition to the filamentous bacteria growth and SVI patterns. During the full-scale investigation, over a 3 year period, it was noted that the SVI was maintained within acceptable operational values (i.e. under 160) during the summer months. Moreover settling in the secondary clarifiers was good and was not affected by the presence of M. parvicella. In contrast, at low mean temperatures during winter, the SVI increased to over 300. Overall, as the temperature decreased, the predominance of M. parvicella became apparent. According to this study, M. parvicella growth could be controlled and SVI could drop under 160 by a change in operational conditions which involved an increase in DO concentration between 2 and 4 mg/L and a decrease in SRT to less than 20 days.

Clinical Validation of Nebulized Budesonide and Effect of Nebulized Budesonide on the Hypothalamic-Pituitary-Adrenal Axis in Adult Patients Admitted with Acute Asthmatic Attack (급성 발작으로 내원한 성인 천식 환자에서 Nebulized Budesonide의 임상적인 효과와 시상하부-뇌하수체-부신 축에 대한 작용)

  • Seo, Ki-Hyun;Moon, Seung-Hyug;Kim, Yong-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.5
    • /
    • pp.529-538
    • /
    • 2002
  • Background : Many clinicians are reluctant to prescribe systemic corticosteroids to manage an asthmatic attack because of many complications such as osteoporosis, cushing's syndrome, diabetes, hypertension and bleeding tendency. The use of nebulized budesonide may be of value in some infants, old men, and in particular adult asthmatic patients who complain of severe dyspnea. A clinical validation and steroid-sparing effect of nebulized budesonide in asthmatic adults and COPD were evaluated, and the short-term effects of budesonide use on the HPA axis were assessed. Materials and Methods : Study A was prospectively done with 41 patients diagnosed with pure asthma and 30 patients diagnosed with COPD (including asthmatic component) in Soonchunhyang Hospital, Chunan from June. 2000 to Sep. 2001. They were treated with nebulized budesonide including systemic steroids (Group 1), a budesonide tubuhaler including a systemic steroid (Group 2), or only the systemic steroid(Group 3). The peak flow rate, arterial blood gas in room air, pulmonary function test, symptom scoring, steroid amount and hospital stay were analyzed. Study B was conducted with 19 patients to evaluate the short-term effects on the HPA axis of treatment with nebulized budesonide 1mg twice daily and a budesonide turbuhaler 5 puffs twice daily. The adrenal function was assessed prior to budesonide inhalation and after 7 days of budesonide inhalation. Results : In the pure asthmatic patients, the mean value of the symptoms (dyspnea, wheezing, cough, night asthma) or the arterial BGAs, total amounts of steroid or hospital stay and the difference in the results of the pulmonary function tests or peak expiratory flow rate were similar in the three groups. In COPD with an asthmatic component, there were no significant differences among the three groups. Although nebulized budesonide suppressed HPA function,(p=0.006) the HPA responses from the nebulized budesonide and turbuhaler budesonide were similar (p=0.288) Conclusion : This result suggests that systemic steroid should only be made available for acute asthmatic patients irrespective of the inhaled budesonides. Nebulized budesonide at the therapeutic dose has similar effects on the HPA axis compared to that of turbuhaler budesonide.

A Study on Effective Management & Administration System for Deluxe Hotel Kitchen in Seoul Area. (관공호텔 조리직무의 분업과 통합에 따른 문제점과 개선방안에 관한 연구)

  • 라영선
    • Culinary science and hospitality research
    • /
    • v.1
    • /
    • pp.57-89
    • /
    • 1995
  • Despite prologed business stagnation of both international and domestic economy, hotel business as well as tourist industry has continuously been keeping growing, owing to increase of surplus income and world flowing population. During recent 4 years, growth rate of yearly mean in domestic hotels reached 9.9% and especially that of the superior class hotels 15.2%. In the composition of domestic tourist hotel's revenue, the earnings of guest rooms form 37.4%, on the other hand those of food & beverage 39.9%. This result is that our hotel business is concentrated on its interest in FOOD & BEVERAGE of which productivity per unit dimension can be increased to an unlimited extent and extent and superior class hotels strengthened in F&B are increasing in comparison with European or American hotels which are focused on guest rooms in their management. For value added rate of F&B is low as compared with increase of their earnings, they are interested in the management techniques which focus on rising the rate. As for the cost of Food & Beverage, personnel expenditure forms 36.5% and the direct materials 31.5%. Therefore how to manage personnel and materials costs which compose as much as 68% of total revenue will greatly affect net profit. We can say that an effective management technique in cost of Food & Beverage is one of the most important know-hows in hotel management. Especially management know-how for the Kitchen Department where the most of foods come out makes a great effects on various expenses, productivity and it is the achievement from hotel management. For the most of the hotel's top managers, they don't seriously take the fact that KITCHEN SYSTEM affects greatly total expenditure. This study starts from the point of recognizing the question of fundamental cause affecting tow largest cost elements incurred in Food & Beverage and trying to present an effective kitchen system. To settle the questions raised, I compared and analyzed productivity and cost of food & beverage and unit kitchen centered around superior class hotels in Seoul, which vary in Kitchen Systems. In order to attain the aforementioned study effectively purpose of this study, I compared Room-Service and Coffee-Shop Menu, flow of basic food in the kitchen, extent and result of division of labor and integration in the kitchen, scale of outlet kitchen, productivity, the turnover rate of food in store, food cost rate one another which all vary in Kitchen Systems. All these elements are compared and analyzed each other being divided into two main groups such as①. Main Production kitchen and Banquet Kitchen, and ②. coffee-shop kitchen and Room-service Kitchen. Therefore this study is to point out the problems in managing kitchens of superior class hotels which are different in systems. An effort was made to find out the better Kitchen System for superior deluxe hotels. I emphasize the followings on the proper scale of division of labor and integration of unit kitchen and a disposition plan for outlet kitchens of restaurant. First, KITCHEN SYSTEM as a sub-system of Hotel Management System is composed of sub-systems of outlet unit kitchen. Basic food materials are cooked and served for the guests while support kitchen and out restaurant kitchen interact organically each other. So Kitchen should be considered as a system composed of integrated sub-systems. Second, support and banquet kitchens should be integrated to be managed. And these unit kitchens have to be designed to be placed in the back of banquet rooms area. Third, coffee-shop kitchen and room-service kitchen should be integrated to be managed. Fourth, several unit business kitchens should be place on the same floor. Fifth, main production kitchens ought to be located near the loading duck, food store and large refrigerator. Sixth, considering the limits of supervision, duties should be adjusted as 12-20 cooks in two shifts a day for a sub-kitchen, and 18-30 cooks in three shifts a day so that labor division can be made. Last, I would like to two points for direction and task of future study. Firstly, I compare the effective income and increasing costs each other, which are incurred by increasing the use rate of the second processing materials for foods perched outside and through the results. I can find out the better points of the processing production and circulation system, and then I study this effects made on hotel kitchen system. Secondly, I can point out that more efficient kitchen system shall be established through comparing and analyzing the matter of amount of indirect costs and flow of food in different kitchen systems.

  • PDF

Effect of ST 36-ST 41 Electro-acupuncture on Regional Cerebral Blood Flow in Normal Volunteers Evaluated by $^{99m}Tc$-ECD SPECT (족삼리-해계 전침치료가 정상인의 국소 뇌혈류에 미치는 영향 -Brain SPECT와 SPM을 이용하여-)

  • Moon, Sang-Kwan;Min, In-Kyu;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Bae, Hyung-Sup;Kim, Young-Suk;Kim, Deok-Yoon
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.130-137
    • /
    • 2010
  • Objectives: So far it has been reported that acupuncture increases cerebral blood supply and stimulates the functional activity of brain nerve cells. Previous studies have demonstrated that frequently used electro-acupuncture (EA) therapies for stroke increased regional cerebral blood flow (rCBF) in normal volunteers. Though ST 36-ST 41 EA is another prevailing therapy for stroke, there had been no report about its effect on rCBF. This study was to evaluate the effect of ST 36-ST 41 EA on rCBF in normal volunteers using single photon emission computed tomography (SPECT) and statistical parametric mapping (SPM). Methods: In the resting state, $^{99m}Tc$-ECD brain SPECT scans were performed on 10 normal volunteers (5 males, 5 female, mean age $23.6{\pm}0.5$ years). On the other study day, 7 days after the resting examination, 15 minutesEA were applied at ST 36 and ST 41 on the right side of the subjects. Immediately after ST36-ST41 EA, the second SPECT images were obtained in the same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by SPM with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: EA applied at the right ST36-ST41 significantly increased rCBF in the right inferior parietal lobule (Brodmann area [BA] 40), right retrosubicular area (BA 48), left inferior parietal lobule (BA 40), left middle temporal gyrus (BA 21), left fusiform gyrus (BA 37), left inferior parietal lobule (BA 39), left inferior temporal gyrus (BA 20), and left somatosensory association cortex (BA 7). However, right ST36-ST41 EA significantly decreased rCBF in the right parahippocampal gyrus (BA 35), right cerebellum, left frontopolar area (BA 10), left orbitofrontal area (BA 11), left dorsolateral prefrontal cortex (BA 9), and left dorsal anterior cingulate cortex (BA 32). Conclusions: These results demonstrate that rightST36-ST41 EA increased rCBF prominently in both inferior parietal lobule (BA 40) and right retrosubicular area (BA 48), which suggest that there be correlation between specific EA and corresponding rCBF.

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

Evaluation of Embolization Effect of Hepatocellular Carcinoma by Hepatic Arterial Flow Study with $^{99m}Tc$-MAA SPECT (간암에서 색전술의 효과를 평가하는데 있어서 $^{99m}Tc$-MAA SPECT를 이용한 간동맥 혈류 검사의 의의)

  • Lee, Byung-Hee;Yoo, Hyung-Sik;Lee, Jong-Doo;Chung, Jin-Ill;Park, Chang-Yun;Lee, Jong-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.62-68
    • /
    • 1994
  • This study was aimed to compare the density of the functional microcirculation of hepatocellular carcinoma (HCC) with normal liver and to investigate the effect of hepatic-arterial oily chemoembolization (HAE) by radionuclide examination. Methods : Eight patients with HCC proven by biopsy in five, and clinically and radiologically in three were included. The mixture of 2 cc normal saline with three to four mCi of $^{99m}Tc$-MAA was infused through a hepatic-arterial catheter for a minute. Dynamic images were obtained at a rate of 4 sec per frame for a minute, and static images and SPECT were followed. Results : In three patients who underwent hepatic arterial angiography (HAA) alone, radioactivity was markedly increased in tumors compared to the adjacent liver immediately after infusion of $^{99m}Tc$-MAA. The ratios of tumoral and extratumoral up-take (T/E ratio) were above 6.5 (range; $6.5{\sim}l9$, mean; 12.5). In four of the five patients who under-went superselective HAE, T/E ratio were remark-ably decreased ($0.5{\sim}1.3$). The areas of embolization were better delineated in radionuclide study than in postembolization HAA. In the other one who was considered to be embolized completely on HAA, strong radiouptake in the tumor was disclosed (T/E ratio; 7.0). Conclusions : Therefore hepatic-arterial flow study with radionuclide imaging using $^{99m}Tc$-MAA can be a valuable method to assess the accurate embolization effect in HCC.

  • PDF

An Analysis into the Characteristics of the High-pass Transportation Data and Information Processing Measures on Urban Roads (도시부도로에서의 하이패스 교통자료 특성분석 및 정보가공방안)

  • Jung, Min-Chul;Kim, Young-Chan;Kim, Dong-Hyo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.74-83
    • /
    • 2011
  • The high-pass transportation information system directly collects section information by using probe cars and therefore can offer more reliable information to drivers. However, because the running condition and features of probe cars and statistical processing methods affect the reliability of the information and particularly because the section travel time is greatly influenced by whether there has been delay by signals on urban roads or not, there can be much deviation among the collected individual probe data. Accordingly, researches in multilateral directions are necessary in order to enhance the credibility of the section information. Yet, the precedent studies related to high-pass information provision have been conducted on the highway sections with the feature of continuous flow, which has a limit to be applied to the urban roads with the transportational feature of an interrupted flow. Therefore, this research aims at analyzing the features of high-pass transportation data on urban roads and finding a proper processing method. When the characteristics of the high-pass data on urban roads collected from RSE were analyzed by using a time-space diagram, the collected data was proved to have a certain pattern according to the arriving cars' waiting for signals with the period of the signaling cycle of the finish node. Moreover, the number of waiting for signals and the time of waiting caused the deviation in the collected data, and it was bigger in traffic jam. The analysis result showed that it was because the increased number of waiting for signals in traffic jam caused the deviation to be offset partially. The analysis result shows that it is appropriate to use the mean of this collected data of high-pass on urban roads as its representative value to reflect the transportational features by waiting for signals, and the standard of judgment of delay and congestion needs to be changed depending on the features of signals and roads. The results of this research are expected to be the foundation stone to improve the reliability of high-pass information on urban roads.

The Effect of Exercise on Pulmonary Function (운동이 폐기능에 미치는 영향)

  • Park, Jae-Seuk;Kim, Youn-Seup;Choi, Eun-Kyoung;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl;Chun, Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.351-359
    • /
    • 1998
  • Background: The effects of exercise on pulmonary function are complex and have been the subject of many investigations. But, there has been disputes about the effect of exercise on spirometric parameters and there is no study about the effect of exercise on IOS(Impulse Oscillometry)parameters. IOS, a new method of pulmonary function test, is based on the relationship between the pressure and flow oscillation which is produced by applying sinusoidal pressure oscillation to the respiratory system via the mouth. Method: Fifty-nine young adults without respiratory symptoms were divided into three groups according to degree of exercise(hard exercise group: mean exercise time is over three hours per week at least for the last one month, light exercise group : between thirty minutes to three hours, nonexercise group : less than thirty minutes) and undertaken pulmonary function test(simple spirometry and IOS). Results: The effects of exercise on spirometric parameters; percentage of predictive value of forced vital capacity(FVC % pred) was higher in hard exercise group than nonexercise group(hard exercise group: $102.4{\pm}14.8$, nonexercise group: $93.7{\pm}9.9$, p=0.017), but there was no significant difference in percentage of predicted value of forced expiratory volume in one second(FEV 1 % pred) and percentage of predicted value of forced expiratory flow 50% (FEF 50% pred) between groups. The effects of exercise on IOS parameters: Reactance at 5Hz(X5) was significantly lower in hard exercise group than nonexercise group(hard exercise group: $-0.166{\pm}0.123hPa/1/s$, nonexercise group: $-0.093{\pm}0.036hPa/1/s$, p=0.006) but there was no significant difference in central resistance(Rc), peripheral resistance(Rp), resonance frequency(RF) and resistance at 5Hz, 20Hz between groups. Conclusion: Hard exercise increased FVC % pred on spirometric parameters and decreased reactance at 5Hz(X5) on IOS parameters.

  • PDF

Acute Effects of Ethanol on Blood Pressure and Renal Function in Rat (Ethanol 급성투여(急性投與)가 흰쥐의 혈압(血壓)과 신기능(腎機能)에 미치는 영향(影響))

  • Bae, Gui-Sook;Park, Jae-Sik;Lee, Won-Jung
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • In order to determine the dose-response relationship of ethanol on blood pressure and renal function, 2 doses of ethanol were intubated into albino rats. For a direct measurement of arterial blood pressure, a polyethylene catheter(PE 10) was implanted in the abdominal aorta, and the other end of the catheter was pulled out of the back of the neck. The experiment was conducted after the rats recovered from the surgery. After emptying their bladders, the rats were placed in a metabolism cage. Mean arterial pressure (MAP) was measured and arterial blood samples were collected through the catheter. Following the collection of the control urine sample, 1 ml of 10 g% (low dose), or 30 g% (high dose) of ethanol/100 g BW was intubated. 1 ml of water/100 g BW was intubated into the control group. MAP and blood samples were taken every hour, and urine samples were collected every 90 min for 3 hours. Blood alcohol concentrations reached a peak at 1 hour (low dose: $105.0{\pm}7.5$, high dose: $214.7{\pm}20.2\;mg%$) and decreased linearly thereafter. Following alcohol ingestion, MAP began to decrease at 15 min and remained at a significantly low level thoughout the 3 hours experimental period(low dose: $112{\pm}2{\rightarrow}102{\pm}4$, high dose: $117{\pm}2{\rightarrow}100{\pm}8\;mmHg$). Urine Flow increased markedly during the first 90 min of ethanol ingestion (low dose: $0.88{\pm}0.20{\rightarrow}1.04{\pm}0.22$, high dose: $0.56{\pm}0.11{\rightarrow}1.35{\pm}0.18\;ml/1.5\;hr$) and decreased during the second 90 min period(low dose: $0.25{\pm}0.06$, high dose: $0.22{\pm}0.06\;ml/1.5\;hr$). Urine flow of the control group decreased gradually during the experiment $(0.88{\pm}0.10{\longrightarrow}0.59{\pm}0.09{\rightarrow}0.45{\pm}0.09\;ml/1.5\;hr)$. These results indicate that the blood-pressure-lowering and diuretic effects of ethanol are dose-related: higher doses of ethanol produce a greater decrease in blood pressure and greater diuresis.

  • PDF