• Title/Summary/Keyword: Mean Equivalent Diameter

Search Result 31, Processing Time 0.026 seconds

평판 가까이에 놓인 타원형 실린더 주위 유동에 관한 연구 (Flow Around an Elliptic Cylinder Placed Near a Plane Boundary)

  • 김성민;이상준
    • 대한기계학회논문집B
    • /
    • 제20권8호
    • /
    • pp.2637-2649
    • /
    • 1996
  • Flow characteristics and aerodynamic forces acting on an elliptic cylinder placed in a plane boundary layer were investigated experimentally. Four cylinder models with axis ratio(major axis to minor axis, AR=A/B) of 1, 2, 3, and 4 having the same equivalent diameter were used in this experiment. The Reynolds number based on the equivalent diameter $D_e$(=20mm) was 13,000. In the case of circular cylinder, regular vortex shedding occurs for the cylinder gaps larger than G/B=0.3 and is not almost related to the boundary layer thickness. But, for the elliptic cylinders, the vortex shedding frequency is increased with increasing the gap ratio (G/B) and the axis ratio (AR) of elliptic cylinders. The maximum drag coefficient acting on a circular cylinder is mainly affected by the boundary layer thickness. But, the elliptic cylinders(AR$\geq$2), except for the smaller gap G/B<0.2, show a nearly constant drag coefficient which is much smaller than that of a circular cylinder. The base pressure on the flat plate decreases with increasing the axis ratio(AR) of the elliptic cylinder. In the case of a circular cylinder, the base pressure has the minimum value at the gap ratio G/B=0.4, but it occurs at G/D=2 for elliptic cylinders. The mean velocity of the cylinder wake is quickly recovered at a small cylinder height ratio(H/$\delta$), but the turbulent intensity is rapidly recovered at a large cylinder height ratio(H/$\delta$). The effective wake region in the plane boundary layer is shrinkaged with increasing the axis ratio(AR) of elliptic cylinder. And the drag coefficient and streamwise turbulent intensity of the elliptic cylinder with AR=4 are less than half of those for the circular cylinder(AR=1).

대향류 확산 화염 중에서 비구형 입자 성장에 관한 해석 (Simulation of the Growth of Non-Spherical Particles in a Counterflow Diffusion Flame)

  • 정재인;황준영;이방원;최만수;정석호
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.997-1009
    • /
    • 1999
  • Silica particle formation and growth process including chemical reaction, coagulation and sintering was studied in a counterflow diffusion flame burner. The counterflow geometry provides a one dimensional flow field, along the stagnation point streamline, which greatly simplifies interpretation of the particle growth characteristics. $SiCl_4$ has been used as the source of silicon in hydrogen/oxygen/argon flames. The temperature profiles obtained by calculation showed a good agreement with experiment data. Using one and two dimensional sectional method, aerosol dynamics equation in a flame was solved, and these two results were compared. The two dimensional section method can consider sintering effect and growth of primary particle during synthesis, thus it showed evolution of morphology of non-spherical particles (aggregates) using surface fractal dimension. The effects of flame temperature and chemical loading on particle dynamics were studied. Geometric mean diameter based on surface area and total number concentration followed the trend of experiment results, especially, the change of diameters showed the sintering effect in high temperature environment.

Characteristics of Hypoxic Pulmonary Vasoconstriction of the Rat: Study by the Vessel Size and Location in the Lung

  • Lee, Sang-Jin;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권3호
    • /
    • pp.321-328
    • /
    • 1999
  • Pulmonary blood vessels with diameters of $200{\sim}400\;{\mu}m$ produce considerably more force in response to vasoconstrictor drugs than those which are either smaller or larger. We have therefore investigated whether or not hypoxic pulmonary vasoconstriction (HPV) is more powerful in vessels of these diameters. We have also looked at the possibility that vessels from different regions of the lung respond differently. To do this we have grouped vessels according to their location within the lung as well as by size. We used a small vessel myograph (Cambustion AM10, Cambridge, UK) to study 208 preconstricted $(1\;{\mu}M\;PGF_{2{\alpha}})$ small pulmonary arteries $(300{\sim}800\;{\mu}m$ diameter when stretched to a tension equivalent to 25 mmHg transmural pressure) from 39 rats anaesthetized with 2% inspired halothane. A biphasic contraction was observed in response to hypoxia (ca. 25 mmHg $Po_2).$ The magnitudes of both the first, transient, phase (PT, peak tension) and of the second, sustained, phase (SST, steady state tension) were measured. The latter was measured 40 min after the start of hypoxia. The first phase was most pronounced in vessels with an average diameter of 423 ${\mu}m$ while the second phase was most pronounced in larger vessels (mean diameter 505 ${\mu}m).$ These maximal responses were all seen in vessels somewhat larger than reported by others. The responses of smaller vessels $(400{\sim}500\;{\mu}m)$ did not depend upon their location within the lung, but those of larger vessels $(600{\sim}700\;{\mu}m)$ showed regional differences. Those from the right lobe and those from the base of the lung gave the largest responses. It was especially noticeable that large vessels (631 ${\mu}m$ diameter) from the base of the right lung gave the biggest responses. Thus HPV seems to occur not in a uniform manner, dependent solely to the size of vessels, but it also depends to some degree on the region of the lung from which vessels have been taken. Furthermore, our results suggest that larger vessels, as well as smaller ones, may contribute significantly to HPV.

  • PDF

전자교반시스템에서 Sleeve 의 크기가 유동특성과 미세조직에 미치는 영향 (The effect of the primary particle of the A356 Alloy according to different wall thickness of the sleeve of die-casting by electromagnetic stirrer)

  • 고재홍;서판기;강충길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.660-663
    • /
    • 2004
  • Recently in the automotive industries, light and high quality material is strongly required because of emissions regulation issues. In the electromagnetic stirring process, it has many merits that are the exact control ability about material processing and a good point of the protection of environment. In this paper, the morphology of the change of primary Al phase in A356 alloy by electro magnetic stirrer was investigated to obtain the globular structure. The parameters are the current, stirring time, pouring temperature and cooling rate of different wall thickness; 5mm, 15mm, 25mm respectively. By proper selection of the processing parameters, globular primary particles can be obtained by electromagnetic stirrer.

  • PDF

전자기장을 이용한 결정립 제어 소재 공정 기술 (The Technology of Material Processing for Gram Size Control by Electromagnetic Stirring)

  • 정용식;서판기;고재홍;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.254-258
    • /
    • 2004
  • Actual trends in automotive industry lead to an increase use of lightweight structures imposing the need fur high strength aluminum alloys with complex shape. In the electromagnetic stirring process, it has many merits which are the exact control ability about material processing and a good point of the protection of environment comparison with the mechanical stirring. The interface of cells consisting of primary particle formed by the electromagnetic stirring due to particle regrowth during cooling the alloy. By electromagnetic stirring process, the microstructure of material has a good point, also it can control the material processing exactly.

  • PDF

수평식 전자교반을 이용한 A356 합금의 결정립 제어 (The Grain Size Control of A356 Aluminum Alloy by Electromagnetic Stirring)

  • 고재홍;서판기;최우식;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.111-114
    • /
    • 2004
  • It is many devices to obtain the globular structure because the globularity of the structure is the key to the low apparent viscosity and also to good rheological properties. In this study, the morphology of the change of primary Al phase in A356 alloy by electro magnetic stirrer was investigated to obtain the globular structure. The parameters are the current, stirring time, pouring temperature individually. The greater current and longer stirring time was to get the finer the primary however in case of over the 80A of current and 60sec of stirring time, the primary Al was merged together and was increased. The effect of pouring temperature has an important effect on the size of primary phase. About the $675^{\circ}C$, the primary Al was very fined.

  • PDF

나선형 기계 교반 장치를 이용한 Al 합금 레오로지 소재의 제조 (Manufacture of Aluminum Alloy Rheology Materials Using Spiral Stirring Equipment)

  • 배정운;한수훈;강충길
    • 소성∙가공
    • /
    • 제17권1호
    • /
    • pp.9-12
    • /
    • 2008
  • Recently, industries and academic institutes have been interested in the rheology forming technology for light weight materials. However, this rheocasting process has advantages such as the high initial investment cost and the lower mechanical properties than thixocasting. In this study, the continuous fabrication of rheological material with a spiral stirring equipment(mechanical stirring system) was newly devised to overcome the disadvantages of rheocasting process. The experimental parameters were stirring time($0{\sim}1200sec$), stirring velocity ($0{\sim}100rpm$) and stirring temperature($650{\sim}680^{\circ}C$). The optimal conditions for fabricated rheological material of A6061 alloy were stirring time at 300sec, stirring velocity at 60rpm and stirring temperature at $650^{\circ}C$. At these results, the equivalent diameter was $45{\sim}65{\mu}m$, mean roundness was $1.4{\sim}1.6$ and Vickers hardness was 60Hv.

Sclerotherapy of Peritoneal Inclusion Cysts: Preliminary Results in Seven Patients

  • Jun Yong Jeong;Seung Hyup Kim
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.164-170
    • /
    • 2001
  • Objective: To evaluate the technical feasibility and the clinical effectiveness of sclerotherapy for the treatment of peritoneal inclusion cysts (PICs). Materials and Methods: Between June 1996 and February 2001, eight PICs in seven female patients aged 28-43 (mean, 36) years were instilled with sclerosant (povidone-iodine in three, ethanol in three, both povidone-iodine and ethanol in one). All seven patients subsequently experienced less abdominal pain. After drainage via an 8.5-Fr pigtail catheter inserted in the PICs (transabdominally in six cases, transvaginally in one), sclerosant equivalent in volume to about one-third that of drained fluid was introduced daily until the drained volume was less than 5ml. Follow-up by means of clinical procedures and ultrasound was performed every three months, at which time the success rate, possible complications and recurrence were determined. Results: Sclerotherapy was technically successful in all seven patients, though immediately after the procedure, minor complications were noted in three patients (mild pain in two, mild fever in one). During the follow-up of 4-60 (mean, 24.7) months, sclerotherapy proved successful and without long-term complications in all seven patients: lower abdominal pain disappeared and the diameter of the cysts decreased more than 50%, with complete regression in four cases. During the follow-up period there was no recurrence. Conclusion: Sclerotherapy following catheter insertion is technically feasible and effective for the treatment of PICs.

  • PDF

전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가 (Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer)

  • 권경태;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.415-421
    • /
    • 2017
  • 전립선암에서 방사선치료의 경우 직장의 선량을 감소시키기 위하여 항문을 통하여 일정한 양의 공기를 주입한 풍선을 이용한다. 이런 이유로 전립선암의 방사선치료는 매일 영상유도를 하기 위하여 CBCT를 획득하고 있다. 치료 전 처음 촬영한 전산화단층촬영과 가장 비슷한 상태의 해부학적 구조를 유지시키기 위하여 전처치를 하고 있지만 완벽하게 일치된다고 할 수 없다. 두 명의 실제 치료계획에서는 방광의 용적은 45.82 cc와 63.43 cc 및 등가직경 4.4 cm, 4.9 cm로 측정되었다. 본 연구의 20회 CBCT 결과에서 방광의 용적은 평균 56.2 cc, 105.6cc로 평가되었다. 치료계획 전산화단층촬영에서 평가된 선량과 A 환자의 기준으로 정한 CBCT의 선량은 PTV Mean dose는 1.74%, Bladder Mean dose는 96.67%의 차이로 평가되었으며, B 환자의 경우 PTV Mean dose는 4.31%, Bladder Mean dose는 97.35%의 차이로 평가되었다. 방광의 용적의 변화에 따라 PTV와 방광의 선량변화가 발생된다는 것을 알 수 있었다. 방광의 용적의 변화에 따른 방광 선량의 상관계수 값은 평균선량 $R^2=-0.94$의 선형성을 나타냈다. 방광의 용적변화에 따른 PTV선량의 상관계수 값은 평균선량 $R^2=0.04$의 선형성을 나타냈다. 방광 용적의 변화에 따라 PTV의 선량 변화가 방광의 선량변화보다 더 크다는 것을 알 수 있었다.

Moisture-dependent Physical Properties of Detarium microcarpum Seeds

  • Aviara, Ndubisi A.;Onaji, Mary E.;Lawal, Abubakar A.
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.212-223
    • /
    • 2015
  • Purpose: Physical properties of Detarium microcarpum seeds were investigated as a function of moisture content to explore the possibility of developing bulk handling and processing equipment. Methods: Seed size, surface area, and 1,000-seed weight were determined by measuring the three principal axes, measuring area on a graph paper, and counting and weighing seeds. Particle and bulk densities were determined using liquid displacement and weight in a measuring cylinder, respectively. Porosity was computed from particle and bulk densities. Roundness and sphericity were measured using shadowgraphs. Angle of repose and static and kinetic coefficients of friction were determined using the vertical cylindrical pipe method, an inclined plane, and a kinetic coefficient of friction apparatus. Results: In the moisture range of 8.2%-28.5% (db), the major, intermediate, and the minor axes increased from 2.95 to 3.21 cm, 1.85 to 2.61 cm, and 0.40 to 1.21 cm, respectively. Surface area, 1,000-seed weight, particle density, porosity, and angle of repose increased from 354.62 to $433.19cm^2$, 3.184 to 3.737 kg, 1060 to $1316kg/m^3$, and 30.0% to 53.1%, respectively, whereas bulk density decreased from 647.6 to $617.2kg/m^3$. Angle of repose increased from $13.9^{\circ}$ to $28.4^{\circ}$. Static and kinetic coefficients of friction varied between 0.096 and 0.638 on different structural surfaces. Conclusions: Arithmetic mean, geometric mean, and equivalent sphere effective diameters determined at the same moisture level were significantly different from each other, with the arithmetic mean diameter being greatest. Surface area, 1,000-seed weight, particle density, porosity, and angle of repose all increased linearly with moisture content. Bulk density decreased linearly with moisture content. The coefficients of friction had linear relationships with moisture content. The highest values of static and kinetic coefficients of friction were observed on galvanized steel and hessian fabric, respectively, whereas the lowest values were observed on fiberglass.