• 제목/요약/키워드: Mean Air Temperature

검색결과 841건 처리시간 0.029초

A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area (부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구)

  • Choi, Sung-Yong;Moon, Deog-Hwan;Lee, Jong-Tae;Song, In-Hyuk;Lee, Cha-Eun;Lee, Sung-Min
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

Comparison of Forced Air Warming and Radiant Heating on Body Temperature and Shivering of Post-operative Patients (수술 후 가온방법에 따른 체온과 전율의 변화)

  • Choi, Kyoung-Hee
    • Korean Journal of Adult Nursing
    • /
    • 제20권1호
    • /
    • pp.135-148
    • /
    • 2008
  • Purpose: This study compared the effects of forced air warming and radiant heating on body temperature and shivering of patients with postoperative hypothermia. Methods: The quasi-experimental study was conducted with two experimental groups who had surgery under general anesthesia; 20 patients of group 1 experimented with the Bair Hugger as a forced air warming and 20 patients of group 2 experimented with the Radiant heater. The study was performed from July 3 to August 31, 2006 in a recovery room of an university hospital in a city. The effects of the experiment were measured by postoperative body temperature and chilling score at arrival and after every 10 minutes. The data were analyzed by t-test or ${\chi}^2$-test, repeated measures ANCOVA using SPSS/WIN 12.0. Results: The mean body temperature showed differences between the Bair Hugger group and Radiant Heater group at 40 minutes(F=-2.579, p=.034), 50minutes(F=-2.752, p=.027), and 60 minutes(F=-2.470, p=.047) after arrival to the recovery room. So, hypothesis 1 was partially accepted. The mean score of shivering showed differences between the Bair Hugger group and the Radiant Heater group, but it had no significant meaning. Hypothesis 2 was not accepted. Conclusion: We need more study to explore the effects and side effects of heating modalities to select a more effective heat treatment. The efficiency of heat modalities with regards to cost benefit, time consumption, and patients' discomfort such as burns should be considered.

  • PDF

Relationships between Seasonal Duration of Sunshine and Air Temperature in Korea (우리나라의 계절별(季節別) 일조시간(日照時間)과 기온(氣溫)의 상관관계(相關關係) 및 분포(分布)에 관(關)한 연구(硏究))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Environmental Agriculture
    • /
    • 제14권2호
    • /
    • pp.155-162
    • /
    • 1995
  • To find out the relationship between duration of sunshine and mean air temperature, monthly climatic data were analyzed in several locations in Korea. Even though mean air temperature was high in summer, duration of sunshine was shorter than winter in Kangneung. Net radiation showed a positive correlation with duration of sunshine and its regression coefficient was the highest in July. An increasing rate of sensible heat flux according to the increment of sunshine hours was significantly high in April and October, but was low in July. In spring and fall, duration of sunshine was positively correlated with the daily temperature difference, but in summer and winter it was negatively correlated with maximum temperature and with the minimum temperature, respectively. In January, one hour increase in sunshine hour lowered the mean air temperature by 1 to $1.7^{\circ}C$.

  • PDF

Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

The Comparison Study of Radiative and Convective Heat Transfer in a Room Air Ventilation (환기구를 가진 실내공간에서 복사 및 대류열전달의 비교 연구)

  • 정효민;정한식;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권3호
    • /
    • pp.229-235
    • /
    • 1997
  • The comparison of radiative and convective heat transfer in a room air ventilation is investi¬gated by a numerical simulation. The room air temperature distributions with radiation are appeared more uniform than without radiation at Gr= 1460 and Re=50. The mean Nusselt number in the radiative heat transfer shows less value than convective heat transfer. The total mean Nusselt number is found Wall 1> Wall 3${\fallingdotseq}$Wall 2 7 Wall 4.

  • PDF

Stochastic Properties of Daily Temperature in Rivers (河川의 日別 水溫差에 대한 推計學的 特性)

  • Ahn, Ryong Me;Lee, Hong Keun
    • Journal of Environmental Health Sciences
    • /
    • 제10권1호
    • /
    • pp.1-12
    • /
    • 1984
  • The stochastic characteristics of the daily range of water temperature variation was analyzed by employing the techniques of autocorrelation coefficient, autoreggresive model and crosscorrelation model. These time series included daily observations on maximum and minimum values of water temperature and air temperature. The measurement was made by automatic recording instrument at Gu-yee and Dook-do in Han River, and at Waegwan and Gu-mi in Nackdong River in 1981. As a result of this study, it was found that (1) The correlogram of daily water temperature ranges $\Delta AT_i$ and daily air temperature $\Delta AT_i$ at Gu-mi and Gu-yee showed the exponential curves. (2) The most high frequency values of $\Delta AT_i$ and $\Delta WT_i$ were 11$\circ$C and 0.5${\circ}C$ respectively at every measuring site. (3) The correlation coefficients between the daily mean air temperature AT$_i$ and the daily mean water temperature were fairly high as 0.966 at Dook-do and 0.949 at Gu-yee, but the correlation coefficients between $\Delta AT_i$ and $\Delta WT_i$ were very low as 0.1074 at Gu-yee and 0.0324 at Dook-Do.

  • PDF

Correlation Analysis between Terra/Aqua MODIS LST and Air Temperature: Mainly on the Occurrence Period of Heat and Cold Waves (Terra/Aqua MODIS LST와 기온과의 상관성 분석: 한파 및 폭염 발생 기간을 중심으로)

  • CHUNG, Jee-Hun;LEE, Yong-Gwan;LEE, Ji-Wan;KIM, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • 제22권4호
    • /
    • pp.197-214
    • /
    • 2019
  • In this study, the correlation analysis was conducted between observed air temperature (maximum, minimum, and mean air temperature) and the daytime and nighttime data of Terra/Aqua MODIS LST(Moderate Resolution Imaging Spectroradiometer Land Surface Temperature) for 86 weather stations. All the data of the recent 11 years from 2008 to 2018 were prepared with daily base. In particular, the characteristics of the cold and heat waves incidence period in 2018 were analyzed. The correlation analysis was performed using the Pearson correlation coefficient(R) and root mean square error(RMSE). As a result of time series analysis, the trend between observed air temperature and MODIS LST were similar, showing the correlation above 0.9 in maximum temperature, above 0.8 in mean and minimum temperature. Especially, the maximum temperature was found to have the highest accuracy with Terra MODIS LST daytime, and the minimum temperature had the highest correlation with Terra MODIS LST nighttime. During the cold wave period, both Terra and Aqua MODIS LST showed higher correlations with nighttime data than daytime data. For the heat wave period, the Aqua MODIS LST daytime data was good, but the overall R was below 0.5. Additional analysis is necessary for further study considering such as land cover and elevation characteristics.

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

Estimation of Air Temperature Changes due to Future Urban Growth in the Seoul Metropolitan Area (수도권지역 미래 도시성장에 따른 기온변화 추정)

  • Kim, Yoo-Keun;Kim, Hyun-Su;Jeong, Ju-Hee;Song, Sang-Keun
    • Journal of Environmental Science International
    • /
    • 제19권2호
    • /
    • pp.237-245
    • /
    • 2010
  • The relationship between air temperatures and the fraction of urban areas (FUA) and their linear regression equation were estimated using land-use data provided by the water management information system (WAMIS) and air temperatures by the Korea Meteorology Administration (KMA) in the Seoul metropolitan area (SMA) during 1975 through 2000. The future FUA in the SMA (from 2000 to 2030) was also predicted by the urban growth model (i.e., SLEUTH) in conjunction with several dataset (e.g., urban, roads, etc.) in the WAMIS. The estimated future FUA was then used as input data for the linear regression equation to estimate an annual mean minimum air temperature in the future (e.g., 2025 and 2030). The FUA in the SMA in 2000 simulated by the SLEUTH showed good agreement with the observations (a high accuracy (73%) between them). The urban growth in the SMA was predicted to increase by 16% of the total areas in 2025 and by 24% in 2030. From the linear regression equation, the annual mean minimum air temperature in the SMA increased about $0.02^{\circ}C$/yr and it was expected to increase up to $8.3^{\circ}C$ in 2025 and $8.7^{\circ}C$ in 2030.

AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION (지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구)

  • Kim, Byong-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF