• 제목/요약/키워드: Maximum quantity

검색결과 499건 처리시간 0.026초

減水劑가 콘크리트에 미치는 影響 (Effects of the Water Reducing Agent on the Concrete)

  • 김종천;도덕현
    • 한국농공학회지
    • /
    • 제24권2호
    • /
    • pp.67-75
    • /
    • 1982
  • A study on the effect of water reducing agent on the various characteristics of concrete has been conducted. The experimental results of the study are summarized as follows. 1. Slump test for the concrete added water reducing setretarding agent in proper quantity have been conducted. According to the test results, the decreasing rate of slump value become bigger than plain concrete with increase of the unit weight of cement and elapse of time 2. In case the proper quantity content of maximum compressive strength in Fig. 5 of water reducing set retarding agent is added, unit weight of water is decreased about 15% or so as compared with plain concrete. with the increase of water reducing set accelerating agent content unit weight of water is decreased much more, And other hand, amount of air entraining shows the increasing tendency with the increase of water reducing agent content. 3. The adding rate of water reducing agent which produce maximum strength shows that WR-CH and WR-SA which is water reducing set-starding agent is 0.2% and WR-CO is 0.5% and that WS-PO which is water reducing set accelerating agent is 0.5 4. compressive strength jof the concrete made of sulfate resistant cement shows less than the strength of normal portland cement at initial strength but the strength of both cement shows almost same at curing age of 28 days. 5. when proper quantity of water reducing set retarding agent is used, boned strength is increased about 15% at curing age of 28days. 6. According to the result of durability test, dynamic young's mudulus of elasticity at plain concrete is decreased about 50% as compared with initial step at 300 cycle of freezing and thawing after curing age of days. on the contarary the concrete used water reducing agent is decreased less than 7%.

  • PDF

Plasma Jet의 동축평행 자계에 의한 영향에 관한 연구 ( 1 ) (A Study on the Influence of Coaxial Parallel Magnetic Field upon Plasma Jet)

  • 전춘생
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.57-69
    • /
    • 1973
  • The aim of this study was to investigate the behaviors of plasma jet under coaxial magnetic field in paralled with it for controlling optical characteristics and input power of plasma jet without impurity and instability of arc plasma column. Because the discharge characteristics of plasma jet were so distinctively different according to the existence or non-existence of magnetic field, the input power, luminous intensity of plasma jet and thermal efficiency were comparatively studied in respect of such variables as arc current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle, with the use of several materials which were different in diameter and length of nozzel. The results were as follows; 1) The voltage tends to show a drooping characteristic at law current and then rises gradually. The luminous intensity of plasma jet increases exponentially with arc current. 2) Arc voltage increases and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity increase in accordance with the quantity of argon flow. 4) At first step, arc voltage increases to maximum value with the growth of flux density and then tends to show a gradual decrease. Luminous intensity decreases with the growth flux density. 5) Arc voltage decreases as the constriction length of nozzle increases, maximum decrease is shown at the constriction length of 20(mm) and it increases beyond that value. The luminous intensity decreases as the constriction length grows. 6) Arc voltage and luminous in tensity increase with the growth of diameters of nozzle. 7) Thermal efficiency has values between 50% and 75%, being influenced by arc current, the quantity of argon flow, flux density, the length of electrode gap and the constriction length of nozzle.

  • PDF

PSC-Edge 거더 라멘교의 정착부에 발생한 시공 균열 거동과 개선 (Behavior and Improvement of Construction Crack occurred on Anchorage of PSC-edge Girder Rahmen Bridge)

  • 옥재호;임성순
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.569-576
    • /
    • 2019
  • PSC-Edge 거더 라멘교는 Edge 거더에 긴장력을 도입하고 정모멘트를 감소시켜 저형고와 장경간화가 가능한 교량이다. 본 교량은 가설벤트가 상부슬래브의 하부에 지지되고 Edge 거더부에 2차 강연선이 긴장된 후 거더 외측 면에 $45^{\circ}$방향의 사인장 균열이 발생하였다. 프리스트레스 정착부의 응력분포 및 파열균열의 양상에 관한 연구가 활발히 진행되었지만 기존 연구 결과는 본 구조물의 실제 형상과 경계조건이 상이하여 명백한 원인분석이 어려운 실정이다. 따라서 본 논문에서는 가설벤트의 경계조건을 추가로 고려된 3D Frame 해석을 수행하였으나 Edge 거더부에서 최대 압축응력이 발생하여 균열을 원인을 규명하기에는 한계가 있었다. 따라서 LUSAS 16.1을 사용한 3D Solid 해석을 수행하였으며 그 결과 Edge 거더의 하부와 상부슬래브의 경계부분에서 최대 주인장응력이 발생하였다. 최대 주인장응력과 방향여현을 사용하여 둔각부 Edge 거더 외측면의 소요 철근량을 분석한 결과 사용 철근량이 부족한 것으로 분석되었다. 따라서 추가 시공된 교량은 기존 교량보다 정착부의 철근량과 철근보강 범위를 확장시켰다. 그 결과 Edge 거더부의 균열은 더 이상 발생하지 않는 것으로 관찰되었다. 이와 유사한 PSC-Edge 거더 형식의 교량을 설계 및 시공할 때 본문에서 제안한 해석 및 보강방법을 적용하면 시공 중 발생하는 Edge 거더 외측면의 균열을 충분히 제어할 수 있을 것으로 기대된다.

최적화기법에 의한 농업용 저수지의 관개면적별 최적용수관리 (Optimal Water Management for Classified Irrigation Area of Agricultural Reservoir by using Optimization Programming)

  • 차상화
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.439-446
    • /
    • 2003
  • In this paper, the study area is selected Sungju Reservoir which was constructed with an agricultural purpose and determined the optimal water management plan among the five cases of classified irrigation area by using Linear Programming. As a results of reservoir operation, the additional water quantity of classified irrigation area showed 16.036${\times}$10$\^$6/m$^3$3/year, 19.404${\times}$10$\^$6/m$^3$/year, 18.864${\times}$100$\^$6/m$^3$/year, 4.032${\times}$10$\^$6/m$^3$/year and 0.672${\times}$10$\^$6/m$^3$/year and the total water supply quantity showed 69.628${\times}$10$\^$6/m$^3$/year, 70.048${\times}$10$\^$6/m$^3$/year, 67.979${\times}$10$\^$ 6/m$^3$/year, 67.979${\times}$10$\^$6/m$^3$/year, and 69.939${\times}$10$\^$6/m$^3$/year respectively. Therefore, the case-II was adopted with water management plan of optimum. It is also known that the maximum irrigation area augmentation effect appears in the case which will use the additional water quantity in field irrigation of the case-II which was adopted.

우수 이용을 위한 포집재료별 포집수량과 수질에 관한 연구 (A Study on Quantity and Quality of Collected Rainwater by Collected Materials)

  • 이영복;이승근;왕창근
    • 상하수도학회지
    • /
    • 제18권1호
    • /
    • pp.66-72
    • /
    • 2004
  • In this study, quantity and quality of collected rainwater by sand, gravel, soil, lawn and concrete surface, as collection materials were investigated and Rainwater Collection Prediction Model was developed to predict the amount of collected rainwater. The quantity of collected rainwater in concrete surface, gravel, sand, soil and lawn collection system was 1,067L(93.2%), 1,006L(87.8%), 902L(78.8%), 800L(69.9%), 788.5L(68.8%) for 8 months period, respectively. The average turbidity of collected rainwater in concrete surface, gravel, sand, soil and lawn collection system was 3.2NTU, 2.2NTU, 1.9NTU, 1.7NTU, 1.5NTU for 8 months period, respectively. For sand collection material, predicted amount by the Model and actual collected amount were 931.5L and 902L, which were very closed. For gravel collection material, predicted amount by Model and actual collected amount were 1,028.21. and 1,006L, which were very closed. To simulate the optimal rainwater storage volume, the rainfall and evaporation data in Dae-jeon city were used. For sand collection system with 30m2 area, the maximum storage volume was $17m^3$ and 62% of the year was secured for use of 240L/day.

전력시장 적용을 위한 쿠르노 모델에서의 역수요함수 추정 방법 제안 (The Method for Estimating the Inverse Demand Curve of Cournot Model in Electricity Market)

  • 강동주;허진;김태현;문영환;이근대;정구형;김발호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.79-87
    • /
    • 2005
  • At present Cournot model is one of the most commonly used theories to analyze the gaming situation in oligopoly market. But there exist several problems to apply this model to electricity market. The representative one is to obtain the inverse demand curve able to be induced from the relationship between market price and demand response. In Cournot model, each player offers their generation quantity to accomplish maximum profit, which is accomplished by reducing their quantity compared with available total capacity. As stated above, to obtain the probable Cournot equilibrium to reflect real market situation, we have to induce the correct demand function first of all. Usually the correlation between price and demand appears on the long-term basis through the statistical data analysis (for example, regression analysis) or by investigating consumer utility functions of several consumer groups classified as residential, industrial, and commercial. However, the elasticity has a tendency to change continuously according to the total market demand size or the level of market price. Therefore it should be updated as trading period passes by. In this paper we propose a method for inducing and updating this price elasticity of demand function for more realistic market equilibrium.

Influence of coarse aggregate properties on specific fracture energy of steel fiber reinforced self compacting concrete

  • Raja Rajeshwari, B.;Sivakumar, M.V.N.
    • Advances in concrete construction
    • /
    • 제9권2호
    • /
    • pp.173-181
    • /
    • 2020
  • Fracture properties of concrete depend on the mix proportions of the ingredients, specimen shape and size, type of testing method used for the evaluation of fracture properties. Aggregates play a key role for changes in the fracture behaviour of concrete as they constitute about 60-75 % of the total volume of the concrete. The present study deals with the effect of size and quantity of coarse aggregate on the fracture behaviour of steel fibre reinforced self compacting concrete (SFRSCC). Lower coarse aggregate and higher fine aggregate content in SCC results in the stronger interfacial transition zone and a weaker stiffness of concrete compared to vibrated concrete. As the fracture properties depend on the aggregates quantity and size particularly in SCC, three nominal sizes (20 mm, 16 mm and 12.5 mm) and three coarse to fine aggregate proportions (50-50, 45-55, 40-60) were chosen as parameters. Wedge Split Test (WST), a stable test method was adopted to arrive the requisite properties. Specimens without and with guide notch were investigated. The results are indicative of increase in fracture energy with increase in coarse aggregate size and quantity. The splitting force was maximum for specimens with 12.5 mm size which is associated with a brittle failure in the pre-ultimate stage followed by a ductile failure due to the presence of steel fibres in the post-peak stage.

Evaluation on Spalling Properties of Specimen Size with PP Fiber and Fireproof Coating

  • Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Miyauchi, Hiroyuki;Park, Gyu-Yeon;Lee, Gwang-Jun
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.353-362
    • /
    • 2011
  • High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's being confined in watertight concrete. This study is aimed to evaluate explosive spalling properties of high strength concrete with ${\square}100{\times}100{\times}200$ mm specimen and ${\square}400{\times}400{\times}1500$ mm column. To prevent spalling of concrete, fireproof coating and PP fiber are used. As a result, ${\square}400{\times}400{\times}1500$ mm column was prevented spalling likes ${\times}100{\times}100{\times}200$ mm specimen. When concrete protected failure to explosive spalling, quantity heat ratio (which fireproof coating specimen to pp fiber mixed specimen) between ${\square}100{\times}100{\times}200$ mm and ${\square}400{\times}400{\times}1500$ mm was maximum value at 20 minute, but difference of quantity heat ratio decreased and quantity heat ratio of each specimen is almost same at 30 minute.

함정운동에 의해 발사대 해치에 작용하는 외란에 관한 연구 (Study on the Disturbance Applied to Launcher Hatch by Ship Motions)

  • 변영철;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1111-1118
    • /
    • 2013
  • In this paper, the disturbance applied to launcher hatch by ship motions is introduced to identify the vertical ship motion disturbance. Basically, ship motions are comprised of 6 degrees of freedom: roll, pitch, yaw, heave, surge and sway. In the case of the shipboard launcher hatch the coupled pitch, heave and roll are significant motions to be transformed to a vertical direction motion. The maximum acceleration values are obtained from the vertical motion model and the ship motion data in accordance with ship type and hatch location on the ship. We verify that the maximum pitch motion mainly influences the launcher hatch and also present the quantity of the maximum load disturbance by the ship's motion acceleration.

구형파 펄스를 인가한 정전분무 장치의 대전량 특성 (Charging Characteristics of Electrostatic Sprayer Applied Square Pulse)

  • 박승록;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.573-578
    • /
    • 2003
  • In this study, new type of induction charging system for electrostatic spraying was manufactured and proposed to improve the electrical safety and charging efficiency. And parameters of proposed system to generate the maximum deposition current with electrical safety were selected and investigated. The selected parameters were frequency of square pulse and thickness of insulation material, outer diameter of device and thickness and positions of electrode. Charging quantity of water drop was measured by deposition current detected from sensing plate indirectly. The maximum deposition current for each parameter were 3.5[uA] at the frequency of 15[kHz] and thickness of 0.25[mm] insulating layer. And maximum deposition currents were 2.8[uA] and 3.0[uA] at 25[mm] outer diameter of charging device and 0.25[mm] thickness of electrode each. Effects of electrode position from spraying nozzle on deposition current was a little.