• 제목/요약/키워드: Maximum inversion temperature

검색결과 36건 처리시간 0.024초

김해에서 관측한 접지역전층의 특성에 관한 연구 (A Study on the Characteristics of Inversion Layer Observed at Kimhae)

  • 박종길;원경미
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.305-315
    • /
    • 1994
  • The field observation was carried out to investigate the characteristics of surface inversion layer at Kimhae using the feild observed date and upper layer meteorological data during 4-5 February 1993. The results of the study can be summarized as follows : The maximum height of surface inversion layer observed at Kimhae is 193m and the height of upper level inversion layer ranges from 2nm to 300m. The surface weather elements was influenced the formation of surface inversion layer. According to the pasquill stability and time variation of temperature with height, both the surface heating from insolation and the disturbance of upper level of inversion layer was influenced the disappearance of inversion layer. And the stability of surface temperature inversion layer generally belongs to the class of F, that of upper level temperature inversion layer commonly to the class of E.

  • PDF

2015년 4월에 제주 서부해역에서 발생한 수온역전층 특성 (Characteristics of Water Temperature Inversion Observed in a Region West of Jeju Island in April 2015)

  • 김성현
    • Ocean and Polar Research
    • /
    • 제42권2호
    • /
    • pp.97-113
    • /
    • 2020
  • In-situ observations were carried out in April 2015 to investigate the occurrence of water temperature inversion in a region west of Jeju Island. Analysis of in-situ in the western part of Jeju island showed that cold water moved to the southeast from the surface to the middle layer and warm water moved from the middle to the lower layer of the northwest direction. The water temperature inversion occurred at 84 stations (63.1%) out of 133 stations. At the boundary of the water temperature inversion layer, it was formed in the middle layer and disappeared. In the strongly appearing, it started from the middle layer to the lower layer. The shape of the water temperature inversion layer was different. As a result of horizontal water temperature slope analysis of the water temperature inversion zone, maximum 0.23℃/km was obtained and the mean was 0.06℃/km. The role of water temperature inversion as an indicator to determine the formation of water front. As a result of the water mass analysis, Jeju Warm Current Water and Tsushima Warm Current Water of high temperature and high salt intruded from the middle to the bottom. In the middle layer occurred as the Yellow Sea Cold Water of low water temperature and low salinity expanded.

동절기 도심지 야간 기온역전에 관한 연구 (A Study on Nocturnal Inversion at Urban Area in Winter)

  • 정해연;이규석
    • 한국환경복원기술학회지
    • /
    • 제13권1호
    • /
    • pp.40-46
    • /
    • 2010
  • In urban area, inversion layer prevents air pollutants from being dispersed. To determine nocturnal inversion characteristics at SookMyung Girls' High School near high-rise residential commercial complex buildings in Seoul, air temperature and humidity data were observed at 10minute interval from December 1st, 2007 to May 2nd, 2008. Temperature-Humidity (T-H) sensors were installed at SMG (SookMyung_Ground) and SMR (SookMyung_Roof), and then these two data were compared, analyzed and examined to illustrate air temperature differences of SMG and SMR. After the analysis, the maximum nocturnal inversion was observed by $3.3^{\circ}C$ at 18:10 on December 26th 2007, at that time the weather condition was clear and weak wind. Nocturnal inversions began 2-3 hours before sunset and it reached maximum inversion just after sunset and continued through nighttime until sunrise or 1-2 hours after sunrise. In terms of seasonal variation nocturnal inversions occurred dominantly in March and April rather than winter season.

해풍 효과에 의한 저층대기구조 변화의 측정 (Observation on Structural Change of Low Level Atmosphere due to Effect of Sea Breeze)

  • 전병일;김유근
    • 한국환경과학회지
    • /
    • 제5권4호
    • /
    • pp.441-451
    • /
    • 1996
  • The surface meteorological and upper layer meteorological observation carried out to investigate influences of sea breeze effect on lower layer atmosphere at Gori nuclear power plant for 29∼30 July, 1996. According to surface meteorological data, the inflow of sea breeze was occurred 11:30 on 29 July, 10:30-on 30 July, respectively, at observation site. And the meteorological tower data showed that wind direction of sea breeze was identified as south-westerly, and wind speed of 58 m was 2 times stronger than that of 10 m. It is notworthy that surface inversion layer which built from the night time to daybreak of next day was not broken off by seab reeze's inflow for daytime, and strong inversion layer observed at 47∼243 m with moderately stable class (F) by URC. It was found that strong stable layer of potential temperature appeared at that layer, maximum relative humidity observed at the bottom of inversion layer and maximum mixing ratio observed in the low of inversion layer.

  • PDF

Tethersonde와 기상탑 관측 자료를 이용한 울산지역 야간 역전에 따른 대기오염도 변화와의 관계 (Nocturnal Inversion Layer observed by Tethersonde and AWS System and its Relation to Air Pollution at Ulsan)

  • 임윤규;김유근;오인보;송상근
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.555-563
    • /
    • 2005
  • This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003, The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0,76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone $(O_3)$ concentration was lower, while nitrogen dioxide $(NO_2)$ concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide $(SO_2)$ concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.

동절기 고층건물 풍하면의 기온역전에 관한 연구 (A Study on Inversion at Leeward Side of High-rise Building in Winter)

  • 정해연;김문성;오성남;이규석
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.583-590
    • /
    • 2010
  • To determine nocturnal inversion characteristics at the leeward side of high-rise building, air temperature data were observed at 10 minute interval from February 22, 2010 to April 15, 2010. The observed data were compared, analyzed and examined to illustrate air temperature differences between the roof (XAR) and surface (XAG) of X apartment. The wind speed, wind direction and precipitation data were also observed at XAR and YJL (Yangjae Stream) sites at the same time. After the analysis, the maximum nocturnal inversion was observed by $4.0^{\circ}C$ at 3:40, 3:50, 4:10 on February 24th 2010, at that time the weather condition was clear and weak wind. Air temperature inversions at the leeward side of high-rise building were observed on whole day in wintertime and air temperature inversion intensity was also higher than other nearby area (SMG).

상온에서 짧은 채널 n-MOSFET의 이동도 감쇠 변수 추추에 관한 연구 (A Study on the Extraction of Mobility Reduction Parameters in Short Channel n-MOSFETs at Room Temperature)

  • 이명복;이정일;강광남
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1375-1380
    • /
    • 1989
  • Mobility reduction parameters are extracted using a method based on the exploitatiion of Id-Vg and Gm-Vg characteristics of short channel n-MOSFETs in strong inversion region at room temperature. It is found that the reduction of the maximum field effect mobility, \ulcornerFE,max, with the channel length is due to i) the difference between the threshold voltage and the gate voltage which corresponds to the maximum transconductance, and ii) the channel length dependence of the mobility attenuation coefficient, \ulcorner The low field mobility, \ulcorner, is found to be independent of the channel length down to 0.25 \ulcorner ofeffective channel length. Also, the channel length reduction, -I, the mobility attenuation coefficient, \ulcorner the threshold voltage, Vt, and the source-drain resistance, Rsd, are determined from the Id-Vg and -gm-Vg characteristics n-MOSFETs.

  • PDF

봄철 강릉지역에서 발생하는 강풍에 대한 연구 (Severe Downslope Windstorms of Gangneung in the Springtime)

  • 장욱;전혜영
    • 대기
    • /
    • 제18권3호
    • /
    • pp.207-224
    • /
    • 2008
  • Severe downslope windstorms observed at Gangneung, Korea in the springtime during the last 30 years are studied to understand their generation mechanisms. 92 severe wind cases are selected for which the maximum instantaneous wind speeds exceed two standard deviation of total mean plus ($18.7ms^{-1}$). They are categorized into the three mechanisms (hydraulic jump, partial reflection, and critical-level reflection) proposed in previous studies based on the flow condition, which is calculated using the wind and temperature profile observed at one upstream rawinsonde station, Osan. Among the three, partial reflection is found to be the most frequent mechanism for the last 30 years (1976 - 2005). To understand the role of inversion in generating severe downslope windstorms, horizontal velocity perturbation was calculated analytically for the atmosphere with an inversion layer. It turned out that the intensity of downslope wind was increased by inversion layer of specific heights, which are well matched with the observations. For better understanding the generation mechanisms, two-dimensional numerical simulations are conducted for the 92 severe wind cases using the ARPS model. In most simulations, surface wind speed exceeds the value of the severe-wind criterion, and each simulated case can be explained by its own generation mechanism. However, in most simulations, the simulated surface wind speed is larger than the observed, due to ignoring the flow-splitting effect in the two-dimensional framework.

p형 반전층을 갖는 ZnO계 자외선 수광소자의 설계 및 제작에 관한 연구 (A Study on the Design and Fabrication of ZnO Based UV Photodetector with p-type Inversion Layer)

  • 오상현;김호걸;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.370-371
    • /
    • 2007
  • To investigate the ZnO thin films which are interested in the next generation of short wavelength LEDs and Lasers and UV photodetector with p-type inversion layer, the ZnO thin films were deposited by. RF sputtering system. Substrate temperature and work pressure is $100^{\circ}C$ and 15 mTorr, respectively, and the purity of ZnO target is 5N. The ZnO thin films were deposited at $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, and $400^{\circ}C$. For sample deposited at $300^{\circ}C$, we observed full width at half maximum (FWHM) of 0.240 and good surface morphology.

  • PDF

구릉지 과원의 고도에 따른 기온변이 (Air Temperature Variation Affected by Site Elevation in Hilly Orchards)

  • 정유란;서희철;윤진일
    • 한국농림기상학회지
    • /
    • 제5권1호
    • /
    • pp.43-47
    • /
    • 2003
  • 2001년 9월부터 2002년 6월까지 소규모 집수역 내 고도가 다른 3개 지점(해발 49, 104, 253m)에서 30분 간격으로 기온을 측정하여 다음과 같은 결과를 얻었다. 평균기온은 100m 당 0.2$^{\circ}C$씩 하강하였으며, 이 감율양상은 낮 시간대 지형에 의한 일사 수광량 변이에 의해 증폭되었다. 그러나 감율양상은 일몰시점부터 고도가 높을수록 기온이 더 높아지는 역전양상으로 전환되어 다음 날 일출시점까지 지속되었다. 이에 따라 계곡기저의 일 최저기온이 253m 지점에 비해 더 낮은 날이 연중 67%를 차지하였고 연평균 기온편차는 1.4$^{\circ}C$ 이었다. 맑은 날의 최저기온 역전강도는 겨울보다 봄가을에 더 커지며 대상지역에서 관측된 최대값은 6$^{\circ}C$ 이었다. 흐리고 비온 날의 최저기온은 감율양상이 지속되었으며 봄가을보다 겨울철의 기온감율이 더 컸다.