• 제목/요약/키워드: Maximum frequency value

검색결과 586건 처리시간 0.028초

LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구 (A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process)

  • 김준범;강준혁;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.

열차주행에 따른 강박스 철도교의 동적응답특성 (Dynamic Responses Characteristics of Steel Box Railway Bridges Subjected to Train Loading)

  • 박선준;강성후;조은평
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.772-778
    • /
    • 2009
  • By rising the interests of the railroad, It has been required the research about railroad structure. And since 2000, the study about railway bridges caused by steel box railway bridges has been only 0.2%. So I was hard to find out about steel box railway bridges. In this study, I evaluate and analyze 4 types(KTX, Saemaeul, Mugunghwa, Freight) of dynamic caused by train loading, natural frequency and damping ratio, verticality deflection and verticality acceleration, end slope deflection, impact factor for dynamic characteristics analysis. natural frequency was measured 2.45Hz~3.34Hz and damping ratio revealed for 1.26~2.84%. Maximum verticality deflection(4.86mm) was sufficiently satisfied the design criteria(30.1mm), but in the case of verticality acceleration's respond, design criteria BRDM(Bridge Design Manual) & CTRL presentation derive rail limit value 0.35g be more than value 6 time recorded, maximum was measured 0.49g in 3 kinds of train(KTX, Saemaeul, Mugunghwa), except for Freight. Survey impact factor of Experiment bridge was 0.20 which is measured when the KTX(15:04) was driving. impact factor is enough contended with design criteria 0.29 which is presented in domestic railway design criteria and thoroughly guarantee the dynamic stability.

  • PDF

열차주행에 따른 강박스 철도교의 동적응답특성 (Dynamic Responses Characteristics of Steel Box Railway Bridges Subjected to Train Loading)

  • 박선준;강성후;조은평
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1306-1314
    • /
    • 2009
  • By rising the interests of the railroad, It has been required the research about railroad structure. And since 2000, the study about railway bridges caused by steel box railway bridges has been only 0.2 %. So I was hard to find out about steel box railway bridges. In this study, I evaluate and analyze 4 types(KTX, Saemaeul, Mugunghwa, Freight) of dynamic caused by train loading, natural frequency and damping ratio, verticality deflection and verticality acceleration, end slope deflection, impact factor for dynamic characteristics analysis. natural frequency was measured 2.45 Hz~3.34 Hz and damping ratio revealed for 1.26~2.84 %. Maximum verticality deflection(4.86 mm) was sufficiently satisfied the design criteria(30.1 mm), but in the case of verticality acceleration's respond, design criteria BRDM(bridge design manual) & CTRL presentation derive rail limit value 0.35 g be more than value 6 time recorded, maximum was measured 0.49 g in 3 kinds of train(KTX, Saemaeul, Mugunghwa), except for Freight. Survey impact factor of Experiment bridge was 0.20 which is measured when the KTX(15:04) was driving. impact factor is enough contended with design criteria 0.29 which is presented in domestic railway design criteria and thoroughly guarantee the dynamic stability.

Quantification of Oxygen Transfer in Test Tubes by Integrated Optical Sensing

  • Wittmann, Christoph;Schutz, Verena;John, Gernot;Heinzle, Elmar
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권5호
    • /
    • pp.991-995
    • /
    • 2004
  • Immobilized sensor spots were applied for online measurement of dissolved $O_2$, in test tubes. Oxygen transport was quantified at varied shaking frequency and filling volumes. The k$_{L}$ a increased with increasing shaking frequency and decreasing filling volume. In non-baffled tubes the maximum $k_{L}a$ value was $70h^{-1}$, equivalent to a maximum $O_2$ transfer capacity of 15mMh^{-1}$. Monitoring of the hydrodynamic profile revealed that the liquid bulk rotated inside the tube with an inclined liquid surface, whereby the angle between the surface and tube wall increased with increasing shaking frequency. The $k_{L}a$ clearly correlated to the surface area. Placement of four baffles into the tubes improved the oxygen transfer up to 3-fold. The highest increase in $k_{L}a$ was observed at high filling volume and high shaking frequency. The maximum $k_{L}a$ in baffled tubes was $100 h^{-1}$.

다중해상도 웨이브렛 해석을 기본으로 한 가시화 영상의 극대값 해석 (Maxima Analysis from Visualized Image based on Multi-Resolution Analysis)

  • 박영식;김옥규
    • 융합신호처리학회논문지
    • /
    • 제11권2호
    • /
    • pp.157-162
    • /
    • 2010
  • 이 논문은 이산 웨이브렛 영역에 기반을 둔 fractal 해석에 관한 것이다. 많이 알려진 퓨리어 변환은 임의 신호의 주파수 해석에 폭넓게 사용되어 왔다. 그러나 이 방법은 시간 축에서 발생하는 갑작스러운 신호 변환과 비정상적인 신호를 주파수 변환 영역에서 검출하기 어렵다. 웨이브렛 영역에서 극대 값은 Lipschitz 지수 표현이 가능하고, 또한 극대값만 사용하여 영상 데이터의 윤곽선 및 데이터 특성을 표현하는 유용함을 나타내었다. 이것은 극대 값만 사용하여 본래 영상을 재생하는 것도 가능하다. 극대값 해석을 위해서 기름을 사용한 가시화 영상을 획득했다. 그런 후 ship model의 가시화 영상에 적용했다. 더욱이 sediment 입자의 붕괴과정에 의한 fractal 차원을 조사하였다. 본 논문은 가시화 영상의 극대값으로 fractal 차원을 계산하였고, 실험으로 얻은 가시화 영상으로부터 얻은 해석도 적은 데이터로 기존의 방법과 같은 결과를 나타냄을 보였다.

골수술용 압전형 초음파 의료기기 개발을 위한 유한요소해석 및 이의 실험적 검증 (Finite Element Analysis for the Development of Bone Surgery Piezoelectric Ultrasonic Medical Device and its Experimental Verification)

  • 송태하;이중호;최종균;이희원
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권5호
    • /
    • pp.319-330
    • /
    • 2022
  • In this study, the optimal driving frequency was derived through finite element analysis (FEA) to optimize the developed piezoelectric ultrasonic medical devices(PUMD) for bone surgery. The core of the PUMD is the piezoelectric ceramic (PZT), which is a vibrator that generates vibration energy. The piezoelectric ceramic shows the maximum current value with respect to the input voltage at the resonance frequency, which generates the maximum mechanical vibration. In the past, various studies have been conducted related to the analysis of PUMD, but most of the research so far has been limited to free vibration analysis. However, in order to derive the accurate resonant frequency, the initial stress generated by bolt tightening in the bolt-clamped Langevin type transducer (BLT) must be considered. In this study, after designing a PUMD, the driving performance according to the bolt tightening value was analyzed through FEA, and this was experimentally verified. First, the resonance mode and frequency response were confirmed through modal and harmonic analysis at 20-40 kHz, which is known as the optimal driving frequency band of PUMD for bone surgery. In addition, the design of the PUMD was confirmed by checking the mechanical behavior of the tip and the piezoelectric ceramic at the resonant frequency. Consequentially, the characteristic evaluation was performed, and it was confirmed that the resonant frequency result derived through the FEA was reasonable. Through this study, we presented a more rational FEA method than before for BLT transducers. We expect that this will shorten the time and cost of developing a PUMD, and will enable the development of more stable and high-quality products.

Praat을 이용한 아동 포먼트 자동 세팅 스크립트 구현 (The implementation of children's automated formant setting by Praat scripting)

  • 박지연;성철재
    • 말소리와 음성과학
    • /
    • 제10권4호
    • /
    • pp.1-10
    • /
    • 2018
  • This study introduces an automated Praat script allowing optimal formant analysis for children's vowels. Using Burg's algorithm in Praat, formants can be extracted by setting the maximum formant value and the number of formants. The optimal formant setting was determined by identifying the two conditions, F1 and F2, with minimum standard deviations. When applying the optimal formant setting determined by the script, the results of normality tests were not significant among all vowels except /e/ for the maximum formant value, and among the vowels /a/, /e/, /i/, /o/, /u/ and /ʌ/ for the number of formants. This indicates that when analyzing the formants of children's vowel sounds, the unilateral application of a parameter setting (the maximum formant value and the number of formants) to all vowels is problematic. The performance of the optimal formant setting script was evaluated along with 3 different algorithm in order to determine whether it properly extracts formants for children's vowels. To this end, Korean monophghongs of 6-year-old children were collected and the Praat scripts were applied to the data. Resultant Formant plots and statistical analysis showed that optimum_script and qtone_script, which links to the perceptual unit, performed very well in formant extraction compared to the remaining 2 scripts.

$LiTaO_3$ crystal의 dynamic 초전특성과 그 주파수의 의존성 (Dynamic Pyroelectric Properties and Their Frequency Dependences of $LiTaO_3$ Crystal)

  • 이원재;강성준;정양희;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제37권8호
    • /
    • pp.35-41
    • /
    • 2000
  • $LiTaO_3$ 단결정 시료의 초전특성에 대한 주파수 의존성을 dynamic 방법을 이용하여 조사하였다. 2 ~ 1000Hz 주파수 범위에서 $LiTaO_3$ 단결정 시료의 전압응답을 부하 저항의 크기에 따라 초전전압영역 ($U_{PV},\;R_L=17.3G{\Omega}$) 과 초전전류영역 ($U_{PV},\;R_L=1M{\Omega}$) 으로 분류하여 측정하였다. 초전전류영역의 전압응답에 의존하는 초전계수는 40 Hz에서 최대값 $1.56{\times}10^{-8}C/cm^2{\cdot}K$를 나타내었고, 전압감도와 검출능을 위한 재료평가지수는 각각 최대값 $10.8{\times}10^{-11}C{\cdot}cm/J$$13{\times}10^{-7}C{\cdot}cm/J$을 나타내었다. 전압감도는 초전전압영역의 전압응답에 의존하여 2 Hz에서 488V/W 의 최대값을 나타내었다. 잡음등가전력과 비검출능은 40 Hz에서 각각 최소값 $3.95{\times}10^{-10}W/{\sqrt}Hz$와 최대값 $5.6{\times}10^8cm{\cdot}{\sqrt}Hz/W$이었다.

  • PDF

Current Control Scheme of High Speed SRM Using Low Resolution Encoder

  • Khoi, Huynh Khac Minh;Ahn, Jin-Woo;Lee, Dong-Hee
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.520-526
    • /
    • 2011
  • This paper presents a balanced soft-chopping circuit and a modified PI controller for a high speed 4/2 Switched Reluctance Motor (SRM) with a 16 pulse per revolution encoder. The proposed balanced soft-chopping circuit can supply double the switching frequency in the fixed switching frequency of power devices to reduce current ripple. The modified PI controller uses maximum voltage, back-emf voltage and PI control modes to overcome the over-shoot current due to the time delay effect of current sensing. The maximum voltage mode can supply a fast excitation current with consideration of the hardware time delay. Then the back-emf voltage mode can suppress the current over-shoot with consideration of the feedback signal delay. Finally, the PI control mode can adjust the phase current to a desired value with a fast switching frequency due to the proposed balanced soft-chopping technology.

더블기어 자동 시각 검사 시스템 실계 및 구현 (Automated Visual Inspection System of Double Gear using Inspection System)

  • 이영교;김영포
    • 디지털산업정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.81-88
    • /
    • 2011
  • Mini Double Gears Frame is critical part of PDP and also produces couple hundred thousand every month. In the process of mass production, product inspection is very important process. Double Gear, one of the part of machine, was inspected by human eyes which caused mistakes and slow progress. To achieve the speed and accuracy the system was compensated by vision system which is inspecting automatically. The focus value is measured based on the fact that high contrast images have much high frequency edge information. High frequency term of the image is extracted using the high-pass filter and the sum of the high frequency term is used as the focus value. We used a Gaussian smoothing filter to reduce the noise and then measures the focus value using the modified Laplacian filter called a Sum modified Laplacian Focus values for the various lens positions are calculated and the position with the maximum focus value is decided as the focused position. The focus values calculated in various lens position showed the Gaussian distribution. We proposed a method to estimate the best focus position using the Gaussian curve fitting. Focus values of the uniform interval lens positions are calculated and the values are used to estimate the Gaussian distribution parameters to find the best focus position.